Intravascular contrast agent improves magnetic resonance angiography of carotid arteries in minipigs

被引:26
|
作者
Lin, WL [1 ]
Abendschein, DR [1 ]
Celik, A [1 ]
Dolan, RP [1 ]
Lauffer, RB [1 ]
Walovitch, RC [1 ]
Haacke, EM [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, Dept Elect Engn, St Louis, MO 63110 USA
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 06期
关键词
MRA; intravascular and extravascular contrast agents; angioplasty;
D O I
10.1002/jmri.1880070605
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was designed to optimize three-dimensional (3D) time-of-night (TOF) magnetic resonance angiography (MRA) sequences and to determine whether contrast-enhanced MRA could improve the accuracy of lumen definition in stenosed carotid arteries of minipigs, 3D TOF MRA was acquired with use of either an intravascular (n = 13) and/or an extravascular contrast agent (n = 5) administrated at 2 to 4 weeks after balloon-induced injury to a carotid artery in 16 minipigs. Vascular contrast, defined as signal intensity differences between blood vessels and muscle normalized to the signal intensity of muscle, was compared before and after the injection of each contrast agent and between the two agents. Different vascular patencies were observed among the animals, including completely occluded vessels (n = 5), stenotic vessels (n = 3), and vessels with no visible stenosis (n = 8), Superior vascular contrast improvement was observed for small arteries and veins and for large veins with the intravascular contrast agent when compared with the extravascular contrast agent. In addition, preliminary studies in two of the animals showed a good correlation for the extent of luminal stenosis defined by digital subtraction angiography compared with MRA obtained after administration of the intravascular contrast agent (R2 =.71, with a slope of.96 +/- .04 by a linear regression analysis). We concluded that use of an intravascular contrast agent optimizes 3D TOF MRA and may improve its accuracy compared with digital subtraction angiography.
引用
收藏
页码:963 / 971
页数:9
相关论文
共 50 条
  • [41] Improved Artery-Vein Separation with Acceleration-Dependent Preparation for Non-Contrast-Enhanced Magnetic Resonance Angiography
    Priest, Andrew Nicholas
    Taviani, Valentina
    Graves, Martin John
    Lomas, David John
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 699 - 706
  • [42] Visualization of the normal cerebral venous system using a contrast-enhanced three-dimensional magnetic resonance angiography technique
    Haroun, A.
    Mahafza, W.
    Rub, M. Abo-El
    Al Najar, M.
    EUROPEAN JOURNAL OF ANATOMY, 2007, 11 (03) : 149 - 154
  • [43] Role of high resolution contrast-enhanced magnetic resonance angiography (HR CeMRA) in management of arterial complications of the renal transplant
    Ismaeel, M. Maged
    Abdel-Hamid, Azza
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) : E122 - E127
  • [44] Magnetic resonance-guided percutaneous angioplasty of femoral and popliteal artery stenoses using real-time imaging and intra-arterial contrast-enhanced magnetic resonance angiography
    Paetzel, C
    Zorger, N
    Bachthaler, M
    Hamer, OW
    Stehr, A
    Feuerbach, S
    Lenhart, M
    Völk, M
    Herold, T
    Kasprzak, P
    Nitz, WR
    INVESTIGATIVE RADIOLOGY, 2005, 40 (05) : 257 - 262
  • [45] Carotid Plaque Diagnosis With 3-Dimensional Computed Tomography Angiography: A Comparison With Magnetic Resonance Imaging-Based Plaque Diagnosis
    Omi, Tatsuo
    Hayakawa, Motoharu
    Adachi, Kazuhide
    Ohba, Shigeo
    Sadato, Akiyo
    Hasebe, Akiko
    Ishihara, Takuma
    Nakahara, Ichiro
    Hirose, Yuichi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (03) : 488 - 493
  • [46] Gadolinium-enhanced magnetic resonance angiography, colour duplex and digital subtraction angiography of the lower limb arteries from the aorta to the tibio-peroneal trunk in patients with intermittent claudication
    Gjonnæss, E
    Morken, B
    Sandbæk, G
    Stranden, E
    Slagsvold, CE
    Jorgensen, JJ
    Nylænde, M
    Abdelnoor, M
    Dullerud, R
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 31 (01) : 53 - 58
  • [47] Contrast-enhanced magnetic resonance angiography (MRA): evaluation of three different contrast agents at two different doses (0.05 and 0.1 mmol/kg) in pigs at 1.5 Tesla
    M. Voth
    Henrik J. Michaely
    C. Schwenke
    B. Vos
    H. Pietsch
    European Radiology, 2011, 21 : 337 - 344
  • [48] Contrast-enhanced magnetic resonance angiography (MRA): evaluation of three different contrast agents at two different doses (0.05 and 0.1 mmol/kg) in pigs at 1.5 Tesla
    Voth, M.
    Michaely, Henrik J.
    Schwenke, C.
    Vos, B.
    Pietsch, H.
    EUROPEAN RADIOLOGY, 2011, 21 (02) : 337 - 344
  • [49] Non-enhanced versus low-dose contrast-enhanced renal magnetic resonance angiography at 7 T: a feasibility study
    Laader, Anja
    Beiderwellen, Karsten
    Kraff, Oliver
    Maderwald, Stefan
    Ladd, Mark E.
    Forsting, Michael
    Umutlu, Lale
    ACTA RADIOLOGICA, 2018, 59 (03) : 296 - 304
  • [50] Three-dimensional contrast-enhanced magnetic resonance angiography for anterolateral thigh flap outlining: A retrospective case series of 68 patients
    Jiang, Chunjing
    Lin, Ping
    Fu, Xiaoyan
    Shu, Jiner
    Li, Huimin
    Hu, Xiaogang
    He, Jianrong
    Ding, Mingxing
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (02) : 1067 - 1074