Magnetic resonance angiography of the carotid arteries using three different techniques: Accuracy compared with intraarterial X-ray angiography and endarterectomy specimens

被引:31
作者
Fellner, C
Lang, W
Janka, R
Wutke, R
Bautz, W
Fellner, FA
机构
[1] Landesnervenklin Wagner Jauregg, Inst Radiol, A-4020 Linz, Austria
[2] Univ Erlangen Nurnberg, Inst Diagnost Radiol, Erlangen, Germany
关键词
magnetic resonance angiography; carotid arteries; contrast-enhanced magnetic resonance angiography; stenosis; specimen;
D O I
10.1002/jmri.20282
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare three different magnetic resonance angiography (MRA) techniques with x-ray angiography and endarterectomy specimens. Materials and Methods: Twenty-one patients underwent x-ray angiography, three-dimensional time-of-flight (TOF) focusing on the carotid bifurcation, high-resolution (HR) contrast enhanced (CE) MRA, and time-resolved CE MRA. arteries were evaluated by three independent observers on identical projection of x-ray angiography and MRA. Maximum stenosis grades on MRA were assessed additionally and correlated with endarterectomy specimens in 12 cases. Results: Sensitivity for the detection of severe stenoses was excellent (100%) for all MRA techniques, and specificity was superior for three-dimensional TOF (96.7%) compared with HR CE MRA (80.6%) and time-resolved CE MRA (83.9%). The correlation between x-ray angiography and MRA for all stenoses was slightly superior for three-dimensional TOF and HR CE MRA compared with the time-resolved technique (kappa = 0.87 and 0.86 vs. 0.84). The same trend was seen for the interobserver agreement and for the correlation with endarterectomy specimens. Eleven up to 17 stenoses (depending on the MRA technique) were graded higher using additional projections. Conclusion: Three-dimensional TOF MRA yielded even more accurate results than HR CE MRA in grading of stenoses near the carotid bifurcation. Therefore, a combination of both methods seems to be advantageous. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:424 / 431
页数:8
相关论文
共 27 条
[1]  
ALTMAN DG, 1995, PRACTICAL STAT MED R, P403
[2]  
Alvarez-Linera J, 2003, AM J NEURORADIOL, V24, P1012
[3]   Grading of internal carotid artery stenosis:: Validation of Doppler/duplex ultrasound criteria and angiography against endarterectomy specimen [J].
Eckstein, HH ;
Winter, R ;
Eichbaum, M ;
Klemm, K ;
Schumacher, H ;
Dörfler, A ;
Schulte, K ;
Neuwirth, A ;
Gross, W ;
Schnabel, P ;
Allenberg, JR .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 21 (04) :301-310
[4]   Multidirectional depiction of internal carotid arterial stenosis:: Three-dimensional time-of-might MR angiography versus rotational and conventional digital subtraction angiography [J].
Elgersma, OEH ;
Wüst, AFJ ;
Buijs, PC ;
van der Graaf, Y ;
Eikelboom, BC ;
Mali, WPTM .
RADIOLOGY, 2000, 216 (02) :511-516
[5]   Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European carotid surgery trial (ECST) [J].
Farrell, B ;
Fraser, A ;
Sandercock, P ;
Slattery, J ;
Warlow, CP .
LANCET, 1998, 351 (9113) :1379-1387
[6]   Different MR angiography techniques provide different results in assessing extracranial carotid artery disease [J].
Fellner, FA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) :468-469
[7]   Imaging of internal carotid arterial stenosis: Is the new standard noninvasive? [J].
Fellner, FA ;
Wutke, R ;
Lang, W .
RADIOLOGY, 2001, 219 (03) :858-859
[8]   Fluoroscopically triggered contrast-enhanced 3D MR DSA and 3D time-of-flight turbo MRA of the carotid arteries: first clinical experiences in correlation with ultrasound, x-ray angiography, and endarterectomy findings [J].
Fellner, FA ;
Fellner, C ;
Wutke, R ;
Lang, W ;
Laub, G ;
Schmidt, M ;
Janka, R ;
Denzel, C ;
Bautz, W .
MAGNETIC RESONANCE IMAGING, 2000, 18 (05) :575-585
[9]  
Huston J, 2001, RADIOLOGY, V218, P138
[10]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351