Response Characteristics of Hydrogen Sensors Based on PMMA-Membrane-Coated Palladium Nanoparticle Films

被引:48
作者
Chen, Minrui [1 ,2 ]
Mao, Peng [4 ,5 ]
Qin, Yuyuan [2 ]
Wang, Jue [2 ]
Xie, Bo [1 ]
Wang, Xiuzhang [1 ]
Han, Deyan [3 ]
Wang, Guo-hong [3 ]
Song, Fengqi [2 ]
Han, Min [2 ]
Liu, Jun-Ming [2 ]
Wang, Guanghou [2 ]
机构
[1] Hubei Normal Univ, Inst Adv Mat, Huangshi 435002, Peoples R China
[2] Nanjing Univ, Natl Lab Solid State Microstruct, Nanjing 210093, Jiangsu, Peoples R China
[3] Hubei Normal Univ, Hubei Collaborat Innovat Ctr Rare Met Chem, Huangshi 435002, Peoples R China
[4] Univ Birmingham, Sch Phys & Astron, Nanoscale Phys Res Lab, Birmingham B15 2TT, W Midlands, England
[5] Nanjing Univ Posts & Telecommun, Coll Elect Sci & Engn, Nanjing 210023, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
hydrogen sensors; PMMA membrane layer; Pd nanoparticle films; H-2-sensing kinetics; electrical transport mechanism; GAS-TRANSPORT; NANOWIRE; SELECTIVITY; PERMEATION; NANOGAPS;
D O I
10.1021/acsami.7b07641
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Coating a polymeric membrane for gas separation is a feasible approach to fabricate gas sensors with selectivity. In this study, poly(methyl methacrylate)-(PMMA-)membrane-coated palladium (Pd) nanoparticle (NP) films were fabricated for high-performance hydrogen (H-2) gas sensing by carrying out gas-phase cluster deposition and PMMA spin coating. No changes were induced by the PMMA spin coating in the electrical transport and H-2-sensing mechanisms of the Pd NP films. Measurements of H-2 sensing demonstrated that the devices were capable of detecting H-2 gas within the concentration range 0-10% at room temperature and showed high selectivity to H-2 due to the filtration effect of the PMMA membrane layer. Despite the presence of the PMMA matrix, the lower detection limit of the sensor is less than 50 ppm. A series of PMMA membrane layers with different thicknesses were spin coated onto the surface of Pd NP films for the selective filtration of H-2. It was found that the device sensing kinetics were strongly affected by the thickness of the PMMA layer, with the devices with thicker PMMA membrane layers showing a slower response to H-2 gas. Three mechanisms slowing down the sensing kinetics of the devices were demonstrated to be present: diffusion of H-2 gas in the PMMA matrix, nucleation and growth of the beta phase in the alpha phase matrix of Pd hydride, and stress relaxation at the interface between Pd NPs and the PMMA matrix. The retardation effect caused by these three mechanisms on the sensing kinetics relied on the phase region of Pd hydride during the sensing reaction. Two simple strategies, minimizing the thickness of the PMMA. membrane layer and reducing the size of the Pd NPs, were proposed to compensate for retardation of the sensing response.
引用
收藏
页码:27193 / 27201
页数:9
相关论文
共 55 条
[1]   Metal oxide hydrogen, oxygen, and carbon monoxide sensors for hydrogen setups and cells [J].
Aroutiounian, Vladimir .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (09) :1145-1158
[2]   Granular electronic systems [J].
Beloborodov, I. S. ;
Lopatin, A. V. ;
Vinokur, V. M. ;
Efetov, K. B. .
REVIEWS OF MODERN PHYSICS, 2007, 79 (02) :469-518
[3]   FUEL CLEANUP SYSTEM - POISONING OF PALLADIUM-SILVER MEMBRANES BY GASEOUS IMPURITIES [J].
CHABOT, J ;
LECOMTE, J ;
GRUMET, C ;
SANNIER, J .
FUSION TECHNOLOGY, 1988, 14 (02) :614-623
[4]   OPERATING CHARACTERISTICS AND COMPARISON OF PHOTOPYROELECTRIC AND PIEZOELECTRIC SENSORS FOR TRACE HYDROGEN GAS-DETECTION .2. PIEZOELECTRIC QUARTZ-CRYSTAL MICROBALANCE SENSOR [J].
CHRISTOFIDES, C ;
MANDELIS, A .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (09) :3986-3992
[5]   Hydrogen-induced microstructural changes of Pd films [J].
Cizek, J. ;
Melikhova, O. ;
Vlcek, M. ;
Lukac, F. ;
Vlach, M. ;
Prochazka, I. ;
Anwand, W. ;
Brauer, G. ;
Muecklich, A. ;
Wagner, S. ;
Uchida, H. ;
Pundt, A. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (27) :12115-12125
[6]   Systematic investigation of the effects of temperature and pressure on gas transport through polyurethane/poly(methylmethacrylate) phase-separated blends [J].
de Sales, J. A. ;
Patricio, P. S. O. ;
Machado, J. C. ;
Silva, G. G. ;
Windmoller, D. .
JOURNAL OF MEMBRANE SCIENCE, 2008, 310 (1-2) :129-140
[7]   A piezoelectric-sound-resonance cavity for hydrogen gas detection [J].
Dong, SX ;
Bai, FM ;
Li, JF ;
Viehland, D .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (09) :1105-1113
[8]   Sound-resonance hydrogen sensor [J].
Dong, SX ;
Bai, FM ;
Li, JF ;
Viehland, D .
APPLIED PHYSICS LETTERS, 2003, 82 (25) :4590-4592
[9]   Hydrogen sensors and switches from electrodeposited palladium mesowire arrays [J].
Favier, F ;
Walter, EC ;
Zach, MP ;
Benter, T ;
Penner, RM .
SCIENCE, 2001, 293 (5538) :2227-2231
[10]   Nanogaps for Sensing [J].
Favier, Frederic .
PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01) :746-749