Hybrid self-calibration method for reference surface elimination in subaperture stitching interferometry

被引:2
|
作者
Liu, WeiJian [1 ]
Gao, Zhishan [1 ]
Wang, Ruoyan [1 ]
Che, Xiaoyu [1 ]
Wang, Lingjie [2 ]
Lei, Lihua [3 ]
Guo, Zhenyan [1 ]
Yuan, Qun [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, Xiao Lingwei Rd 200, Nanjing 210094, Jiangsu, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Key Lab Opt Syst Adv Mfg Technol, Changchun 130033, Peoples R China
[3] Shanghai Key Lab Online Test & Control Technol, Shanghai 201203, Peoples R China
基金
中国国家自然科学基金;
关键词
Subaperture stitching; Wavefront interferometry; Error elimination; LARGE FLAT;
D O I
10.1016/j.optcom.2022.128278
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Subaperture stitching interferometry (SSI) is an essential method for the map testing of large-aperture optical components. The surface map of a reference surface is a typical error source. In this study, we propose a hybrid self-calibration method to eliminate the reference surface error in SSI by combining the modified shift-rotation method and the maximum likelihood method. The traditional shift-rotation method is a general full-aperture absolute interferometric measurement that can retain localized irregularities. The shift-rotation operations are leveraged to generate a couple of subapertures covering the surface under test, whereby a ring of subapertures and a central subaperture are acquired by rotations and a lateral shift, respectively. The modified shift-rotation method is proposed to obtain the rotationally asymmetric components of the test surface in the ring of subapertures. The same components within the central subaperture are retrieved using the maximum likelihood method. Then, the rotationally symmetric components of the test surface are acquired using the least squares method, utilizing the measured data before and after the shift. Reference surface maps are sufficiently eliminated from the measured data. High-frequency components of the test surface are also retained, which engender high-accuracy SSI. Simulations are conducted to verify the proposed method. The positioning errors of the proposed method are analysed and discussed. Subaperture testing experiments of a 100-mm aperture flat are performed and compared with full-aperture absolute measurement results. The stitched errors with 0.018 2 PV and 0.003 2 RMS are obtained.
引用
收藏
页数:9
相关论文
共 5 条
  • [1] Subaperture stitching interferometry with reduced reference errors for ultrasmooth surfaces
    Xu, Xudong
    Huang, Qiushi
    Shen, Zhengxiang
    Wang, Zhanshan
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS VI, 2016, 9962
  • [2] Effect of Reference Surface Error on Subaperture Stitching for Flat Optics
    Li Mengyang
    Cao Tingfen
    Yuan Xiaodong
    Zhang Jinli
    Liu Changchun
    Yi Congzhi
    Chen Haiping
    Quan Xusong
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2019, 46 (12):
  • [3] Effect of Reference Surface Error on Subaperture Stitching for Flat Optics
    Li M.
    Cao T.
    Yuan X.
    Zhang J.
    Liu C.
    Yi C.
    Chen H.
    Quan X.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2019, 46 (12):
  • [4] Robust subaperture stitching method based on three-dimensional surface data matching
    Li, Lulu
    Liu, Qian
    Huang, Wen
    OPTICAL ENGINEERING, 2019, 58 (03)
  • [5] Measurement of aspheric surfaces using annular subaperture stitching interferometry based on an automatic positioning method: theory and application
    Wen, Yongfu
    Cheng, Haobo
    OPTICAL ENGINEERING, 2014, 53 (07)