Directly suspended droplet microextraction and analysis of amitriptyline and nortriptyline by GC

被引:38
作者
Sarafraz-Yazdi, Ali
Raouf-Yazdinejad, Samaneh [1 ]
Es'haghi, Zarrin
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Chem, Mashhad, Iran
[2] Payame Noor Univ, Fac Sci, Dept Chem, Tehran, Iran
关键词
gas chromatography; directly suspended droplet microextraction; amitriptyline and nortriptyline; antidepressants;
D O I
10.1365/s10337-007-0373-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Directly Suspended Droplet Microextraction (DSDME) was used for the determination of two tricyclic antidepressant drugs (TCAs), amitriptyline and nortriptyline. In this technique, an aqueous sample is agitated with a stirring bar, creating a mild vortex at the center of the via]. A droplet of an immiscible organic solvent is placed at the bottom of the vortex. After 20 min a portion of the organic droplet is withdrawn with a syringe and injected into the GC. Experimental conditions, such as the extraction solvent, extraction time, solvent volume, stirring rate, pH and salt addition were optimized. In order to evaluate the practical application of the method, relative standard deviations, linearity range and limits of detection were calculated. Typical enrichment factors were 167 and 179 for amitriptyline and nortriptyline, respectively. The method was applied to the determination of these drugs in urine samples.
引用
收藏
页码:613 / 617
页数:5
相关论文
共 31 条
[1]   Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma [J].
Basheer, C ;
Lee, HK ;
Obbard, JP .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) :161-169
[2]   On-line field-amplified sample stacking in capillary electrophoresis for analysis of amitriptyline and its metabolite nortriptyline in plasma [J].
Chen, CC ;
Wu, SM ;
Huang, YH ;
Ko, WK ;
Kou, HS ;
Wu, HL .
ANALYTICA CHIMICA ACTA, 2004, 517 (1-2) :103-110
[3]  
Chen PS, 2006, TALANTA, V69, P669, DOI 10.1016/j.talanta.2005.10.042
[4]   Chiral liquid chromatographic determination of mirtazapine in human plasma using two-phase liquid-phase microextraction for sample preparation [J].
de Santana, FJM ;
de Oliveira, ARM ;
Bonato, PS .
ANALYTICA CHIMICA ACTA, 2005, 549 (1-2) :96-103
[5]   Single-drop liquid-phase microextraction for the determination of hypericin, pseudohypericin and hyperforin in biological fluids by high performance liquid chromatography [J].
Gioti, EM ;
Skalkos, DC ;
Fiamegos, YC ;
Stalikas, CD .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1093 (1-2) :1-10
[6]   Trace analysis of ten chlorinated benzenes in water by headspace solid-phase microextraction [J].
He, Y ;
Wang, Y ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (01) :149-154
[7]   Polymer-coated fibrous extraction medium for sample preparation coupled to microcolumn liquid-phase separations [J].
Imaizumi, M ;
Saito, Y ;
Hayashida, M ;
Takeichi, T ;
Wada, H ;
Jinno, K .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 30 (06) :1801-1808
[8]  
Liska I, 2000, J CHROMATOGR A, V885, P3, DOI 10.1016/S0021-9673(99)01144-9
[9]   Application of single-drop microextraction and comparison with solid-phase microextraction and solid-phase extraction for the determination of α- and β-endosulfan in water samples by gas chromatography-electron-capture detection [J].
López-Blanco, MC ;
Blanco-Cid, S ;
Cancho-Grande, B ;
Simal-Gándara, J .
JOURNAL OF CHROMATOGRAPHY A, 2003, 984 (02) :245-252
[10]   Evolution of solid-phase microextraction technology [J].
Lord, H ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :153-193