The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates

被引:91
作者
Wargocki, P [1 ]
Wyon, DP [1 ]
Fanger, PO [1 ]
机构
[1] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
关键词
call-center; filter; SBS symptoms; office work; outdoor air supply rate; productivity;
D O I
10.1111/j.1600-0668.2004.00304.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A 2 x 2 replicated field intervention experiment was conducted in a call-center providing a telephone directory service: outdoor air supply rate was adjusted to be 8% or 80% of the total airflow of 430 l/s (3.5/h) and the supply air filters were either new or had been in place for 6 months. One of these independent variables was changed each week for 8 weeks. The interventions did not affect room temperature, relative humidity or noise level. The 26 operators were blind to conditions and each week returned questionnaires recording their environmental perceptions and Sick Building Syndrome (SBS) symptoms. Their performance was continuously monitored by recording the average talk-time every 30 min. Replacing a used filter with a clean filter reduced talk-time by about 10% at the high ventilation rate but had no significant effect at the low rate. Increasing the outdoor air supply rate reduced talk-time by 6% with a new filter in place but increased talk-time by 8% with a used filter in place. The interventions also had significant effects on some SBS symptoms and environmental perceptions. The present results indicate that increasing outdoor air supply rate and replacing filters can have positive effects on health, comfort and performance.
引用
收藏
页码:7 / 16
页数:10
相关论文
共 29 条
[1]  
[Anonymous], ASHVE T
[2]  
Bluyssen P., 1993, Air Infiltration Review, V14, P9
[3]   The impact of allergies and allergy treatment on worker productivity [J].
Burton, WN ;
Conti, DJ ;
Chen, CY ;
Schultz, AB ;
Edington, DW .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2001, 43 (01) :64-71
[4]   AIR-POLLUTION SOURCES IN OFFICES AND ASSEMBLY HALLS, QUANTIFIED BY THE OLF UNIT [J].
FANGER, PO ;
LAURIDSEN, J ;
BLUYSSEN, P ;
CLAUSEN, G .
ENERGY AND BUILDINGS, 1988, 12 (01) :7-19
[5]  
Fisk W. J., 2002, P 9 INT C IND AIR QU, V1, P790
[6]  
Gholami S., 1997, Proceedings of IAQ'97 Healthy Buildings, V1, pp, P545
[7]  
Hujanen M., 1991, P HLTH BUILD IAQ 91, P329
[8]   Risk of sick leave associated with outdoor air supply rate, humidification, and occupant complaints [J].
Milton, DK ;
Glencross, PM ;
Walters, MD .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (04) :212-221
[9]   The effect of air temperature on labour productivity in call centres -: A case study [J].
Niemelä, R ;
Hannula, M ;
Rautio, S ;
Reijula, K ;
Railio, J .
ENERGY AND BUILDINGS, 2002, 34 (08) :759-764
[10]   A LONGITUDINAL-STUDY RELATING CARPETING WITH SICK BUILDING SYNDROME [J].
NORBACK, D ;
TORGEN, M .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :129-135