Conformationally Constrained (Coumarin-Triazolyl-Bipyridyl) Click Fluoroionophore as a Selective Al3+ Sensor

被引:283
作者
Maity, Debabrata [1 ]
Govindaraju, T. [1 ]
机构
[1] Jawaharlal Nehru Ctr Adv Sci Res, New Chem Unit, Bioorgan Chem Lab, Bangalore 560064, Karnataka, India
关键词
ALUMINUM TOXICITY; DESIGN; CHEMOSENSORS; COMPLEXES; ZINC(II); IONS;
D O I
10.1021/ic1009994
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A conformationally constrained (coumarin pyrrolidinyl triazolyl bipyridyl) fluoroionophore conjugate was synthesized through click chemistry. The fluoroionophore serves as a selective chemosensor for Al3+ based on internal charge transfer. The coumarin bipyridyl chemosensor exhibited a high association constant with submicromolar detection for the aluminum ion.
引用
收藏
页码:7229 / 7231
页数:3
相关论文
共 33 条
[1]   Aluminium fluorescence detection with a FRET amplified chemosensor [J].
Arduini, M ;
Felluga, F ;
Mancin, F ;
Rossi, P ;
Tecilla, P ;
Tonellato, U ;
Valentinuzzib, N .
CHEMICAL COMMUNICATIONS, 2003, (13) :1606-1607
[2]   Fluorescent Conjugated Polymer Nanoparticles by Polymerization in Miniemulsion [J].
Baier, Moritz C. ;
Huber, Johannes ;
Mecking, Stefan .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (40) :14267-14273
[3]   Fast root growth responses, root exudates, and internal detoxification as clues to the mechanisms of aluminium toxicity and resistance: a review [J].
Barcelo, J ;
Poschenrieder, C .
ENVIRONMENTAL AND EXPERIMENTAL BOTANY, 2002, 48 (01) :75-92
[4]   A novel pyrenyl-appended tricalix[4]arene for fluorescence-sensing of Al(III) [J].
Ben Othman, Amel ;
Lee, Jeong Won ;
Huh, Young-Duk ;
Abidi, Rym ;
Kim, Jong Seung ;
Vicens, Jacques .
TETRAHEDRON, 2007, 63 (44) :10793-10800
[5]   Aluminium speciation in relation to aluminium bioavailability, metabolism and toxicity [J].
Berthon, G .
COORDINATION CHEMISTRY REVIEWS, 2002, 228 (02) :319-341
[6]   Water-soluble benzo- and naphtho-thiadiazole-based bistriazoles and their metal-binding properties [J].
Brombosz, Scott M. ;
Appleton, Anthony Lucas ;
Zappas, Andrew J., II ;
Bunz, Uwe H. F. .
CHEMICAL COMMUNICATIONS, 2010, 46 (09) :1419-1421
[7]   EPIDEMIC ALUMINUM INTOXICATION IN HEMODIALYSIS-PATIENTS TRACED TO USE OF AN ALUMINUM PUMP [J].
BURWEN, DR ;
OLSEN, SM ;
BLAND, LA ;
ARDUINO, MJ ;
REID, MH ;
JARVIS, WR .
KIDNEY INTERNATIONAL, 1995, 48 (02) :469-474
[8]   PREDICTING AQUEOUS ALUMINUM CONCENTRATIONS IN NATURAL-WATERS [J].
CRONAN, CS ;
WALKER, WJ ;
BLOOM, PR .
NATURE, 1986, 324 (6093) :140-143
[9]   ALUMINUM TOXICITY AND TOLERANCE IN PLANTS [J].
DELHAIZE, E ;
RYAN, PR .
PLANT PHYSIOLOGY, 1995, 107 (02) :315-321
[10]  
Fasman GD, 1996, COORDIN CHEM REV, V149, P125, DOI 10.1016/0010-8545(96)89157-0