Miniaturization of electrospray ionization mass spectrometry

被引:28
作者
Wood, TD
Moy, MA
Dolan, AR
Bigwarfe, PM
White, TP
Smith, DR
Higbee, DJ
机构
[1] SUNY Buffalo, Dept Chem, Buffalo, NY 14260 USA
[2] SUNY Buffalo, Dept Biol Struct, Buffalo, NY 14260 USA
[3] Nanogenesys Inc, New York, NY USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
D O I
10.1081/ASR-120021167
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The development of electrospray ionization (ESI) has proved an enormous breakthrough in structural biology because it provides a means for transferring large biological molecules into the gas-phase as intact charged ions. In the post-genomics era, increased attention has been focused on mass spectrometry techniques capable of providing structural information for biological molecules-especially proteins-with minimal sample consumption. Miniaturized ESI, known as either microspray or nanospray, is of keen interest in structural biology because of its low sample consumption requirements, low flow rates (nL/min), and improved ion transfer efficiency from source to detector vs. conventional ESI sources. Here, the principles of ESI are detailed, followed by a discussion on the development, advantages, and applications of miniaturized ESI, especially as applied in structural biology. Along the way, we also highlight some of our own research aimed at producing high-durability nanospray emitters for utility in coupling capillary separations techniques with miniaturized ESI sources.
引用
收藏
页码:187 / 244
页数:58
相关论文
共 276 条
[91]  
Haley TM, 1998, J MASS SPECTROM, V33, P1246, DOI 10.1002/(SICI)1096-9888(199812)33:12<1246::AID-JMS743>3.0.CO
[92]  
2-E
[93]   Identification of a new metabolite of macrolide immunosuppressant, like rapamycin and SDZ RAD, using high performance liquid chromatography and electrospray tandem mass spectrometry [J].
Hallensleben, K ;
Raida, M ;
Habermehl, G .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (06) :516-525
[94]  
Hannis JC, 1998, RAPID COMMUN MASS SP, V12, P443, DOI 10.1002/(SICI)1097-0231(19980430)12:8<443::AID-RCM183>3.0.CO
[95]  
2-E
[96]   Hydrogen/deuterium exchange of hydrophobic peptides in model membranes by electrospray ionization mass spectrometry [J].
Hansen, RK ;
Broadhurst, RW ;
Skelton, PC ;
Arkin, IT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (12) :1376-1387
[97]   Mass spectrometry of polymers and polymer surfaces [J].
Hanton, SD .
CHEMICAL REVIEWS, 2001, 101 (02) :527-569
[98]  
Happersberger HP, 1998, EUR MASS SPECTROM, V4, P209
[99]   Defection and identification of carcinogen-peptide adducts by nanoelectrospray tandem mass spectrometry [J].
Harriman, SP ;
Hill, JA ;
Tannenbaum, SR ;
Wishnok, JS .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (03) :202-207
[100]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897