An evaluation of internal carotid artery and cerebral blood flow volume using color duplex sonography in patients with vertebral artery hypoplasia

被引:17
作者
Acar, M [1 ]
Degirmenci, B [1 ]
Yucel, A [1 ]
Albayrak, R [1 ]
Haktanir, A [1 ]
机构
[1] Afyon Kocatepe Univ, Fac Med, Dept Radiol, TR-03200 Afyon, Turkey
关键词
vertebral artery hypoplasia; Doppler; cerebral blood flow volume; internal carotid artery;
D O I
10.1016/j.ejrad.2004.05.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Vertebral artery hypoplasia (VAH) may be defined as VA flow volume below approximate to 30-40 mL/min using color duplex sonography. The aim of this study was to evaluate the effect of VAH on internal carotid artery (ICA) flow volume and cerebral blood flow (CBF) volume. Material and methods: In this study, 17 patients with VAH and 20 control subjects with normal VA flow volume were enrolled. The patients and control subjects were 50-75 years aged. The ICA and VA flow volumes were determined by using color duplex sonography. The ICA and CBF volumes of patients with VAH were compared with control group flow volumes. Results: There was no statistically significant difference in flow volumes of right, left and sum of both ICA between VAH and control group. However, CBF volume was lower in patient with VAH than control group. Conclusions: Evaluation of CBF using color duplex sonography is noninvasive and easily applicable to all patients and provides valuable diagnostic data. To the best of our knowledge, this is the first study demonstrating lower CBFV and normal ICA flow volume in patients with VAH. (c) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:450 / 453
页数:4
相关论文
共 18 条
  • [1] BENDICK PJ, 1990, SURG CLIN N AM, V70, P235
  • [2] Effect of age on cerebral blood flow: Measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults
    Buijs, PC
    Krabbe-Hartkamp, MJ
    Bakker, CJG
    de Lange, EE
    Ramos, LMP
    Breteler, MMB
    Mali, WPTM
    [J]. RADIOLOGY, 1998, 209 (03) : 667 - 674
  • [3] Diagnosis and management of vertebral artery stenosis
    Cloud, GC
    Markus, HS
    [J]. QJM-AN INTERNATIONAL JOURNAL OF MEDICINE, 2003, 96 (01) : 27 - 34
  • [4] Dörfler P, 2000, J CEREBR BLOOD F MET, V20, P269
  • [5] Kashimada A, 1995, Radiat Med, V13, P95
  • [6] Color-coded duplex ultrasonography of the origin of the vertebral artery: Normal values of flow velocities
    Kuhl, V
    Tettenborn, B
    Eicke, BM
    Visbeck, A
    Meckes, S
    [J]. JOURNAL OF NEUROIMAGING, 2000, 10 (01) : 17 - 21
  • [7] Ultrasound examination of carotid and vertebral arteries
    Landwehr, P
    Schulte, O
    Voshage, G
    [J]. EUROPEAN RADIOLOGY, 2001, 11 (09) : 1521 - 1534
  • [8] DECREASES IN REGIONAL CEREBRAL BLOOD-FLOW WITH NORMAL AGING
    MARTIN, AJ
    FRISTON, KJ
    COLEBATCH, JG
    FRACKOWIAK, RSJ
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (04) : 684 - 689
  • [9] Nicolau C, 2001, J ULTRAS MED, V20, P105
  • [10] Flow velocity and flow volume measurements in the extracranial carotid and vertebral arteries in healthy adults:: Reference data and the effects of age
    Scheel, P
    Ruge, C
    Schöning, M
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08) : 1261 - 1266