Bleaching/blinking assisted localization microscopy for superresolution imaging using standard fluorescent molecules

被引:162
作者
Burnette, Dylan T. [1 ]
Sengupta, Prabuddha [1 ]
Dai, Yuhai [2 ]
Lippincott-Schwartz, Jennifer [1 ]
Kachar, Bechara [2 ]
机构
[1] Eunice Kennedy Shriver Natl Inst Child Hlth & Hum, Bethesda, MD 20892 USA
[2] Natl Inst Deafness & Other Commun Disorders, Lab Cell Struct & Dynam, NIH, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
nanoscopy; diffraction limit; immunofluorescence; subcellular localization; GFP; OPTICAL RECONSTRUCTION MICROSCOPY; SUBDIFFRACTION-RESOLUTION; EXCITATION MICROSCOPY; ELECTRON-MICROSCOPY; CELLS; PROBES; NANOSCOPY; LIGHT; FLUOROPHORES; IMPROVEMENT;
D O I
10.1073/pnas.1117430109
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Superresolution imaging techniques based on the precise localization of single molecules, such as photoactivated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM), achieve high resolution by fitting images of single fluorescent molecules with a theoretical Gaussian to localize them with a precision on the order of tens of nanometers. PALM/STORM rely on photoactivated proteins or photoswitching dyes, respectively, which makes them technically challenging. We present a simple and practical way of producing point localization-based superresolution images that does not require photoactivatable or photoswitching probes. Called bleaching/blinking assisted localization microscopy (BaLM), the technique relies on the intrinsic bleaching and blinking behaviors characteristic of all commonly used fluorescent probes. To detect single fluorophores, we simply acquire a stream of fluorescence images. Fluorophore bleach or blink-off events are detected by subtracting from each image of the series the subsequent image. Similarly, blink-on events are detected by subtracting from each frame the previous one. After image subtractions, fluorescence emission signals from single fluorophores are identified and the localizations are determined by fitting the fluorescence intensity distribution with a theoretical Gaussian. We also show that BaLM works with a spectrum of fluorescent molecules in the same sample. Thus, BaLM extends single molecule-based superresolution localization to samples labeled with multiple conventional fluorescent probes.
引用
收藏
页码:21081 / 21086
页数:6
相关论文
共 44 条
  • [21] Three-dimensional super-resolution imaging by stochastic optical reconstruction microscopy
    Huang, Bo
    Wang, Wenqin
    Bates, Mark
    Zhuang, Xiaowei
    [J]. SCIENCE, 2008, 319 (5864) : 810 - 813
  • [22] Breaking the Diffraction Barrier: Super-Resolution Imaging of Cells
    Huang, Bo
    Babcock, Hazen
    Zhuang, Xiaowei
    [J]. CELL, 2010, 143 (07) : 1047 - 1058
  • [23] Whole-cell 3D STORM reveals interactions between cellular structures with nanometer-scale resolution
    Huang, Bo
    Jones, Sara A.
    Brandenburg, Boerries
    Zhuang, Xiaowei
    [J]. NATURE METHODS, 2008, 5 (12) : 1047 - 1052
  • [24] Jones SA, 2011, NAT METHODS, V8, P499, DOI [10.1038/nmeth.1605, 10.1038/NMETH.1605]
  • [25] TRACKING OF SINGLE FLUORESCENT PARTICLES IN 3 DIMENSIONS - USE OF CYLINDRICAL OPTICS TO ENCODE PARTICLE POSITION
    KAO, HP
    VERKMAN, AS
    [J]. BIOPHYSICAL JOURNAL, 1994, 67 (03) : 1291 - 1300
  • [26] Subdiffraction resolution in far-field fluorescence microscopy
    Klar, TA
    Hell, SW
    [J]. OPTICS LETTERS, 1999, 24 (14) : 954 - 956
  • [27] Differentially oriented populations of actin filaments generated in lamellipodia collaborate in pushing and pausing at the cell front
    Koestler, Stefan A.
    Auinger, Sonja
    Vinzenz, Marlene
    Rottner, Klemens
    Small, J. Victor
    [J]. NATURE CELL BIOLOGY, 2008, 10 (03) : 306 - U33
  • [28] Correlated fluorescence and 3D electron microscopy with high sensitivity and spatial precision
    Kukulski, Wanda
    Schorb, Martin
    Welsch, Sonja
    Picco, Andrea
    Kaksonen, Marko
    Briggs, John A. G.
    [J]. JOURNAL OF CELL BIOLOGY, 2011, 192 (01) : 111 - 119
  • [29] Using conventional fluorescent markers for far-field fluorescence localization nanoscopy allows resolution in the 10-nm range
    Lemmer, P.
    Gunkel, M.
    Weiland, Y.
    Mueller, P.
    Baddeley, D.
    Kaufmann, R.
    Urich, A.
    Eipel, H.
    Amberger, R.
    Hausmann, M.
    Cremer, C.
    [J]. JOURNAL OF MICROSCOPY, 2009, 235 (02) : 163 - 171
  • [30] McKinney SA, 2009, NAT METHODS, V6, P131, DOI [10.1038/nmeth.1296, 10.1038/NMETH.1296]