Accurate signal-source localization in brain slices by means of high-density microelectrode arrays

被引:13
作者
Obien, Marie Engelene J. [1 ,2 ,3 ]
Hierlemann, Andreas [1 ]
Frey, Urs [1 ,2 ,3 ]
机构
[1] Swiss Fed Inst Technol, Dept Biosyst Sci & Engn, Basel, Switzerland
[2] RIKEN, Quantitat Biol Ctr, Kobe, Hyogo, Japan
[3] MaxWell Biosyst AG, Basel, Switzerland
基金
瑞士国家科学基金会; 欧洲研究理事会;
关键词
SINGLE-CELL ELECTROPORATION; FIELD POTENTIALS; IN-VITRO; NEURONS; CONDUCTIVITY; ORIGIN; STIMULATION; RECORDINGS; EXPRESSION; EEG;
D O I
10.1038/s41598-018-36895-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Extracellular recordings by means of high-density microelectrode arrays (HD-MEAs) have become a powerful tool to resolve subcellular details of single neurons in active networks grown from dissociated cells. To extend the application of this technology to slice preparations, we developed models describing how extracellular signals, produced by neuronal cells in slices, are detected by microelectrode arrays. The models help to analyze and understand the electrical-potential landscape in an in vitro HD-MEA-recording scenario based on point-current sources. We employed two modeling schemes, (i) a simple analytical approach, based on the method of images (MoI), and (ii) an approach, based on finite-element methods (FEM). We compared and validated the models with large-scale, high-spatiotemporal-resolution recordings of slice preparations by means of HD-MEAs. We then developed a model-based localization algorithm and compared the performance of MoI and FEM models. Both models provided accurate localization results and a comparable and negligible systematic error, when the point source was in saline, a condition similar to cell-culture experiments. Moreover, the relative random error in the x-y-z-localization amounted only up to 4.3% for z-distances up to 200 mu m from the HD-MEA surface. In tissue, the systematic errors of both, MoI and FEM models were significantly higher, and a pre-calibration was required. Nevertheless, the FEM values proved to be closer to the tissue experimental results, yielding 5.2 mu m systematic mean error, compared to 22.0 mu m obtained with MoI. These results suggest that the medium volume or "saline height", the brain slice thickness and anisotropy, and the location of the reference electrode, which were included in the FEM model, considerably affect the extracellular signal and localization performance, when the signal source is at larger distance to the array. After pre-calibration, the relative random error of the z-localization in tissue was only 3% for z-distances up to 200 mu m. We then applied the model and related detailed understanding of extracellular recordings to achieve an electrically-guided navigation of a stimulating micropipette, solely based on the measured HD-MEA signals, and managed to target spontaneously active neurons in an acute brain slice for electroporation.
引用
收藏
页数:19
相关论文
共 73 条
  • [1] Robotic Automation of In Vivo Two-Photon Targeted Whole-Cell Patch-Clamp Electrophysiology
    Annecchino, Luca A.
    Morris, Alexander R.
    Copeland, Caroline S.
    Agabi, Oshiorenoya E.
    Chadderton, Paul
    Schultz, Simon R.
    [J]. NEURON, 2017, 95 (05) : 1048 - +
  • [2] [Anonymous], P BIOM ENG SOC BMES
  • [3] [Anonymous], 2006, ELECT FIELDS BRAIN N, DOI DOI 10.1093/ACPROF:OSO/9780195050387.001.0001
  • [4] [Anonymous], 2010, ANAL BIOANAL CHEM, DOI DOI 10.1007/s00216-010-3744-2
  • [5] [Anonymous], P 9 INT M SUBSTR INT
  • [6] [Anonymous], 2018, BRAIN NEUROSCI ADV
  • [7] [Anonymous], COLD SPRING HARB PRO
  • [8] [Anonymous], P 9 INT M SUBSTR INT
  • [9] [Anonymous], AXON INITIAL SEGMENT
  • [10] [Anonymous], 1999, MATH METHODS PHYS