Web crippling design of cold-formed steel built-up I-sections

被引:14
作者
He, Jun [1 ]
Young, Ben [2 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
关键词
Cold-formed steel; Built-up I-sections; Web crippling; Screw arrangements; Direct strength method; RECTANGULAR HOLLOW SECTIONS; DIRECT STRENGTH DESIGN; CHANNEL BEAMS; TUBULAR SECTIONS; TESTS; BEHAVIOR; SUBJECT; SQUARE;
D O I
10.1016/j.engstruct.2021.113731
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports the experiments, numerical modelling and design of cold-formed steel built-up I-sections subjected to localised loadings. The built-up I-sections were made up of two equal-sized plain channels fastened back-to-back in the web. The web crippling tests were undertaken on 41 built-up I-section members under Interior-Two-Flange (ITF), End-Two-Flange (ETF), Interior-One-Flange (IOF) and End-One-Flange (EOF) loading conditions. The effects of the arrangement of screws along the web height were investigated. After the experi-ments, finite element (FE) analyses considering the initial local imperfections of the web of the specimens were performed and the validity of the FE models was assessed using the test results. A parametric investigation including 258 numerical simulations was conducted to expand the database and evaluate the influences of the screw arrangements in the web height. The test and numerical results indicated that the failure modes of the specimens with different screw arrangements were generally similar in each loading condition, and the screws located close to the flange-web junctions of the sections could generally provide maximum web crippling re-sistances of the built-up I-sections. The design recommendations on the arrangements of screws along the web height were proposed. The experimentally and numerically generated web crippling resistances were utilized to assess the current North American specification (AISI S100), Australian and New Zealand standard (AS/NZS 4600) and European code (EN1993-1-3). The results show that the existing codified design formulas lead to either conservative or highly unsafe results. Therefore, two sets of design formulas were derived on the basis of unified equation and direct strength method.
引用
收藏
页数:23
相关论文
共 48 条
  • [11] Bhakta BH, 1992, CIVIL ENG STUDY 92 1
  • [12] Cain DE, 1995, CIVIL ENG STUDY 95 2
  • [13] Direct Strength Design of Cold-Formed C-Sections for Shear and Combined Actions
    Cao Hung Pham
    Hancock, Gregory J.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2012, 138 (06): : 759 - 768
  • [14] Experimental investigation on cold-formed steel lipped channel beams affected by local-distortional interaction under non-uniform bending
    Chen, Man-Tai
    Young, Ben
    Martins, Andre Dias
    Camotim, Dinar
    Dinis, Pedro Borges
    [J]. THIN-WALLED STRUCTURES, 2021, 161 (161)
  • [15] Experimental investigation of cold-formed steel channels with slotted webs in shear
    Degtyareva, N. V.
    Degtyarev, V. V.
    [J]. THIN-WALLED STRUCTURES, 2016, 102 : 30 - 42
  • [16] European Committee for Standardization (EC3), 2006, EN199313 EC3
  • [17] Torsion in thin-walled cold-formed steel beams
    Gotluru, BP
    Schafer, BW
    Peköz, T
    [J]. THIN-WALLED STRUCTURES, 2000, 37 (02) : 127 - 145
  • [18] Web crippling tests of cold-formed steel channels under two flange load cases
    Gunalan, S.
    Mahendran, M.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 110 : 1 - 15
  • [19] EXPERIMENTAL STUDY OF UNLIPPED CHANNEL BEAMS SUBJECT TO WEB CRIPPLING UNDER ONE FLANGE LOAD CASES
    Gunalan, Shanmuganathan
    Mahendran, Mahen
    [J]. ADVANCED STEEL CONSTRUCTION, 2019, 15 (02): : 165 - 172
  • [20] Hetrakul N, 1978, CIVIL ENG STUDY 78 4