Performance and design analyses of various configurations of dew point evaporative cooling-based desiccant air-conditioning (DAC) systems for hot and humid conditions

被引:2
作者
Lao, Marco [1 ]
Lin, Jie [2 ]
Miksik, Frantisek [1 ,3 ]
Thu, Kyaw [1 ,3 ]
Miyazaki, Takahiko [1 ,3 ]
机构
[1] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Dept Energy & Environm Engn, 6-1 Kasuga Koen, Kasuga, Fukuoka 8168580, Japan
[2] UCL, Dept Chem Engn, Gower St, London WC1 6BT, England
[3] Kyushu Univ, Res Ctr Next Generat Refrigerant Properties NEXT, Int Inst Carbon Neutral Energy Res WPI I2CNER, Nishi Ward, 744 Motooka, Fukuoka 8190385, Japan
关键词
Desiccant air-conditioning; Dew point evaporative cooling; Space cooling; Regeneration temperature; Waste heat; Thermal comfort; SOLID-DESICCANT; COUNTER-FLOW; MAISOTSENKO CYCLE; DEHUMIDIFICATION;
D O I
10.1007/s44189-022-00011-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermally driven desiccant- and evaporative cooling-based technologies are promising greener and cheaper alternatives to compressor-based systems due to the separate handling of latent and sensible loads. Desiccant air-conditioning (DAC) systems comprise a desiccant dehumidifier, a sensible cooling unit, a heat source for regeneration, and a heat recovery unit. These components of a DAC system can be arranged in various ways to give different configurations with varying advantages and disadvantages. In this study, five configurations of thermally driven desiccant dehumidifier- and dew point evaporative cooling (DPEC)-based DAC systems were investigated. Seven evaluation criteria namely regeneration temperature, desiccant moisture removal capacity, COPt, DPEC L/H, heat exchanger UA, system size, and fan power requirement were employed. Results show that the standard cycle in ventilation mode offers the highest COPt despite having the highest regeneration temperature. Recirculation of the return room air can operate at a significantly lower regeneration temperature at the expense of larger equipment size and much lower COPt. DAC with an internally cooled dehumidification can operate at low regeneration temperature at the expense of higher fan power and slightly lower COPt. Dividing the dehumidification process into two stages can offer operation at moderately lower regeneration temperature without severely affecting the other criteria. This study can serve as a guide for the selection of an appropriate DAC configuration for space cooling depending on the objective criteria and the resources available.
引用
收藏
页数:14
相关论文
共 32 条
  • [1] [Anonymous], 1999, BUILD SERV ENG RES T
  • [2] ASHRAE, 2007, AE HDB HEAT VENT AIR
  • [3] Comparison between the conventional and recirculation modes in desiccant cooling cycles and deriving critical efficiencies of components
    Bourdoukan, P.
    Wurtz, E.
    Joubert, P.
    [J]. ENERGY, 2010, 35 (02) : 1057 - 1067
  • [4] D. of E. (Philippines), 2016, COMP PHIL EN STAT IN
  • [5] Design, fabrication and performance evaluation of a compact regenerative evaporative cooler: Towards low energy cooling for buildings
    Duan, Zhiyin
    Zhao, Xudong
    Li, Junming
    [J]. ENERGY, 2017, 140 : 506 - 519
  • [6] A mathematical model for predicting the performance of the solar energy assisted hybrid air conditioning system, with one-rotor six-stage rotary desiccant cooling system
    Elzahzby, Ali M.
    Kabeel, A. E.
    Bassuoni, M. M.
    Abdelgaied, Mohamed
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 77 : 129 - 142
  • [7] Exergoenvironmental Evaluation of the Desiccant Air-Conditioning System Subjected to Different Regeneration Temperatures
    Enteria, Napoleon
    Yoshino, Hiroshi
    Sataki, Akira
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (04)
  • [8] Performance assessment and transient optimization of air precooling in multi-stage solid desiccant air conditioning systems
    Gadalla, Mohamed
    Saghafifar, Mohammad
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 119 : 187 - 202
  • [9] Experimental study on a two-stage rotary desiccant cooling system
    Ge, T. S.
    Li, Y.
    Wang, R. Z.
    Dai, Y. J.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (03): : 498 - 508
  • [10] Goldsworthy M., 2014, DESICCANT ASSISTED C, DOI [10.1007/978-1-4471-5565-2, DOI 10.1007/978-1-4471-5565-2]