Diode laser transscleral cyclophotocoagulation for the treatment of refractory glaucoma after penetrating keratoplasty

被引:32
|
作者
Ocakoglu, O
Arslan, OS
Kayiran, A
机构
[1] Univ Istanbul, Cerrahpasa Med Sch, Dept Ophthalmol, Glaucoma Div, Istanbul, Turkey
[2] Univ Istanbul, Cerrahpasa Med Sch, Dept Ophthalmol, Cornea Div, Istanbul, Turkey
关键词
diode laser TSCPC; penetrating keratoplasty; refractory glaucoma;
D O I
10.1080/02713680590968529
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effect and safety of diode laser transscleral cyclophotocoagulation ( TSCPC) in eyes with refractory glaucoma after penetrating keratoplasty (PK). Methods: Diode laser TSCPC was performed on 32 eyes of 32 patients with secondary glaucoma after penetrating keratoplasty. The mean follow-up period was 11.4 +/- 3.8 months (range, 6-20 months). The intraocular pressure (IOP), number of glaucoma medications, graft status, side effects, and complications of the procedure were all recorded during the follow-up period. The treatment was considered successful if after one cyclodiode treatment the IOP could be reduced to or below 22 mmHg with or without medication. The success rate of the diode laser treatment was analyzed by the Kaplan-Meier survival analysis method during the 6th and 12th months of the follow-up period and the end of the study. The decrease in drug requirement after laser treatment was analyzed by the Wilcoxon nonparametric test. Statistical significance was set at p < 0.05. Results: During the follow-up period, diode laser TSCPC reduced the IOP significantly. Our cumulative success rate was 56 % at the end of the study. Cyclodiode treatment resulted in an IOP less than 22 mmHg in 97 % of the eyes on the 6th month and 72 % of the eyes on the 12th month with or without medication. The total retreatment rate of the study was 44 %. More than one treatment was necessary, 8 times in the 1st month, 9 times in the 3rd month, 5 times in the 6th month and 3 times in the 12th month. The average number of antiglaucomatous drugs used was 2.8 before surgery and 1.2 after the 12th month follow-up period (p < 0.05). No eyes with graft failure after treatment were present. Visual acuity improved ( > 2 Snellen lines of acuity) in two eyes and remained the same in the others. No serious side effects such as phthisis bulbi or hypotonia were observed. Conclusions: Diode laser TSCPC appears to be a safe and effective procedure for the treatment of uncontrolled glaucoma secondary to penetrating keratoplasty.
引用
收藏
页码:569 / 574
页数:6
相关论文
共 50 条
  • [31] TREATMENT OF REFRACTORY GLAUCOMA WITH ND-YAG LASER CYCLOPHOTOCOAGULATION
    KOPEL, J
    VALTOT, F
    POIRIER, C
    MOULIN, F
    MOREL, C
    HAUT, J
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1995, 18 (01): : 13 - 21
  • [32] Comparison of ultrasound cycloplasty and transscleral cyclophotocoagulation for refractory glaucoma in Chinese population
    Qiuli Yu
    Ya Liang
    Fangfang Ji
    Zhilan Yuan
    BMC Ophthalmology, 20
  • [33] Clinical Efficacy and Safety Profile of Micropulse Transscleral Cyclophotocoagulation in Refractory Glaucoma
    Williams, Alice L.
    Moster, Marlene R.
    Rahmatnejad, Kamran
    Resende, Arthur F.
    Horan, Teresa
    Reynolds, Michael
    Yung, Edward
    Abramowitz, Benjamin
    Kuchar, Sarah
    Waisbourd, Michael
    JOURNAL OF GLAUCOMA, 2018, 27 (05) : 445 - 449
  • [34] Long-Term Results of Transscleral Diode Laser Cyclophotocoagulation in Glaucoma: A Real-Life Study
    Sari, Cem
    Alagoz, Nese
    Omeroglu, Asena
    Cakir, Ihsan
    Pasaoglu, Isil
    Altan, Cigdem
    Yasar, Tekin
    JOURNAL OF GLAUCOMA, 2024, 33 (06) : 437 - 443
  • [35] Long-term follow-up after transscleral diode laser photocoagulation in refractory glaucoma
    Pucci, V
    Tappainer, F
    Borin, S
    Bellucci, R
    OPHTHALMOLOGICA, 2003, 217 (04) : 279 - 283
  • [36] Transscleral diode laser contact cyclophotocoagulation in the treatment of different glaucomas, also as primary surgery
    Karoline Kramp
    Hans-Peter Vick
    Rudolf Guthoff
    Graefe’s Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 698 - 703
  • [37] Long-term results of transscleral cyclophotocoagulation in refractory pediatric glaucoma patients
    Autrata, R
    Rehurek, J
    OPHTHALMOLOGICA, 2003, 217 (06) : 393 - 400
  • [38] Glaucoma Escalation after Penetrating Keratoplasty
    Al-Mohaimeed, Mansour
    IRANIAN JOURNAL OF OPHTHALMOLOGY, 2010, 22 (04): : 2 - 12
  • [39] A study of glaucoma after penetrating keratoplasty
    França, ET
    Arcieri, ES
    Arcieri, RS
    Rocha, FJ
    CORNEA, 2002, 21 (03) : 284 - 288
  • [40] Glaucoma after penetrating keratoplasty and keratoprosthesis
    Khair, D.
    El-Khoury, J.
    Thompson, P.
    Racine, L.
    Harissi-Dagher, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (03):