Design and simulation of diatom-based microcantilever immunobiosensor for the early detection of Karnal bunt

被引:7
|
作者
Mishra, Manjita [1 ]
Singh, Shailendra Kumar [1 ]
Shanker, Rama [2 ]
Sundaram, Shanthy [1 ]
机构
[1] Univ Allahabad, Ctr Biotechnol, Prayagraj 211002, Uttar Pradesh, India
[2] Motilal Nehru Natl Inst Technol, Dept Civil Engn, Prayagraj 211004, Uttar Pradesh, India
关键词
Karnal bunt; Tilletia indica; Diatom frustules; Biosensor; Microcantilever; Simulation;
D O I
10.1007/s13205-020-02191-8
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Fungal pathogen, Tilletia indica, the cause of Karnal bunt disease in wheat, is severely affecting the yield and grain quality, worldwide. Thus, strict quarantine regulations by most wheat growing countries have to be followed, leading to trade barriers for wheat export. The conventional methods being used for pathogen detection at symptomatic stage requires the germination of Tilletia spores for the processing of samples. Thus, it is time-consuming and expensive. This study proposes a simulated microcantilever-based piezoelectric biosensor for the early detection of T. indica. Four different materials, SiO2, SiC, Si3N4, and Poly Si, were used for the microcantilever design. Microcantilever was coated with siliceous frustules of diatom that provides high surface area and enhanced sensitivity for specific antibody against the antigen, T. indica. Ansys software was used for the simulation analysis. Simulation results showed that microcantilever beam of SiO2 length of 150 mu m, width of 30 mu m and thickness 1 mu m enhanced the sensitivity by two times against the antibody in comparison to normal microcantilever beam. The results concluded that SiO2 with coated diatom is the best material for the microcantilever fabrication, thus, providing an excellent protocol for fabrication of microcantilever-based biosensor which is both cost- and time effective.
引用
收藏
页数:13
相关论文
共 16 条
  • [1] Design and simulation of diatom-based microcantilever immunobiosensor for the early detection of Karnal bunt
    Manjita Mishra
    Shailendra Kumar Singh
    Rama Shanker
    Shanthy Sundaram
    3 Biotech, 2020, 10
  • [2] Detection of typhoid fever by diatom-based optical biosensor
    Selvaraj, Viji
    Muthukumar, Anbazhagi
    Nagamony, Ponpandian
    Chinnuswamy, Viswanathan
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (21) : 20385 - 20390
  • [3] Detection of typhoid fever by diatom-based optical biosensor
    Viji Selvaraj
    Anbazhagi Muthukumar
    Ponpandian Nagamony
    Viswanathan Chinnuswamy
    Environmental Science and Pollution Research, 2018, 25 : 20385 - 20390
  • [4] Design and TEM simulation of a MEMS based microcantilever cardiac marker sensor
    Vidhya S.
    Kumar G.P.
    Mathew L.
    Journal of Nanotechnology in Engineering and Medicine, 2010, 1 (01)
  • [5] Photonic crystal fiber-based blood components detection in THz regime: Design and simulation
    Bulbul A.A.-M.
    Jibon R.H.
    Biswas S.
    Pasha S.T.
    Sayeed M.A.
    Sensors International, 2021, 2
  • [6] Supporting early design stages of technical systems by knowledge-based simulation
    Langer, U
    Lehmann, A
    COOPERATIVE KNOWLEDGE PROCESSING FOR ENGINEERING DESIGN, 1999, : 161 - 175
  • [7] Design and simulation of UUV-based underwater sensor network vigilance and detection system
    Zhou, Gang
    Tian, Xiaodong
    Liu, Zhong
    Li, Lu
    2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-3, 2006, : 317 - +
  • [8] Design and simulation of AIN-Based FBAR Resonator for Hydrogen sulfide Gas detection
    Hashwan, Saeed S. Ba
    Khir, M. H. Md
    Al-Douri, Y.
    Algamili, Abdullah S.
    Alabsi, Sami S.
    2021 IEEE INTERNATIONAL CONFERENCE ON SENSORS AND NANOTECHNOLOGY (SENNANO), 2021, : 73 - 76
  • [9] Design, simulation and performance analysis of MEMS based bio-sensors for the detection of cholera and diarrhea
    Vineetha, K. V.
    Sravani, K. Girija
    Sailaja, B. V. S.
    Guha, Koushik
    Varma, P. Srinivas
    Rao, K. Srinivasa
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2018, 24 (12): : 4785 - 4797
  • [10] Simulation Study on Early Stress Corrosion Damage Detection of Austenitic Stainless Steel Based on Nonlinear Surface Wave
    Shi Y.
    Li P.
    Zhao J.
    Cheng C.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2020, 56 (10): : 50 - 56