Heat transfer enhancement for U-pipe evacuated tube solar absorber by high-emissivity coating on metal fin

被引:18
作者
Chen, Xiaomeng [1 ,2 ]
Yang, Xudong [1 ,2 ,3 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing, Peoples R China
[3] Tsinghua Univ, Shanxi Res Inst Clean Energy, Taiyuan 030032, Peoples R China
基金
中国国家自然科学基金;
关键词
U-pipe evacuated tube; Efficiency improvement; Compound parabolic concentrator; Heat transfer enhancement; Theoretical analysis; THERMAL PERFORMANCE; COLLECTOR; DESIGN; SHAPE; CONCENTRATORS; ASSESSMENTS; EFFICIENCY; NANOFLUID; SYSTEMS;
D O I
10.1016/j.jobe.2022.104213
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the solar thermal field, the U-pipe evacuated tube collector has been widely used to provide hot water for domestic usage and space heating, or integrated with concentrating reflector to deliver thermal power in higher temperature range. Enhancing heat transfer process inside the U-pipe evacuated tube has significant effect on improving the overall thermal efficiency of the collector. However, the current heat transfer enhancement methods require either structure modification or material property change, and are therefore difficult to be promoted for commercial use. Herein, we proposed an easy and feasible method of depositing a high-emissivity coating on a metal fin to enhance the interior heat transfer. The effect of applying this method on the U-pipe evacuated tube with and without compound parabolic concentrator integration was investigated by numerical simulation. We found that this method exerts elevating improvement effect with an increasing operating temperature of the collector. The proposed method yields a maximum improvement of 2.7% for a single U-pipe evacuated tube operating up to 150 ?degrees C. Higher optimization effect was achieved in the case of compound parabolic concentrator integration. By employing this method, we found an 8.4% performance improvement when the tube is combined with a concentrator with concentration ratio of 6.0 at an operation temperature of 200 ?degrees C. At the background that the structure of the U-pipe has been mature and commercialized for a long time, the proposed method with easy-feasibility and low cost is expected to have potential for implementation.
引用
收藏
页数:17
相关论文
共 55 条
[31]   Numerical study on the heat transfer characteristics of filled-type solar collector with U-tube [J].
Ma, Liangdong ;
Zhao, Tianyi ;
Zhang, Jili ;
Zhao, Dan .
APPLIED THERMAL ENGINEERING, 2016, 107 :642-652
[32]   Thermal performance analysis of the glass evacuated tube solar collector with U-tube [J].
Ma, Liangdong ;
Lu, Zhen ;
Zhang, Jili ;
Liang, Ruobing .
BUILDING AND ENVIRONMENT, 2010, 45 (09) :1959-1967
[33]   NEW REFLECTOR DESIGN WHICH AVOIDS LOSSES THROUGH GAPS BETWEEN TUBULAR ABSORBERS AND REFLECTORS [J].
MCINTIRE, WR .
SOLAR ENERGY, 1980, 25 (03) :215-220
[34]   Experimental investigation and numerical modelling on the performance assessments of evacuated U - Tube solar collector systems [J].
Naik, B. Kiran ;
Bhowmik, Mrinal ;
Muthukumar, P. .
RENEWABLE ENERGY, 2019, 134 :1344-1361
[35]   Experimental study on thermal performance of U-type evacuated glass tubular solar collector with low inlet temperature [J].
Nie, Xianhua ;
Zhao, Li ;
Deng, Shuai ;
Lin, Xueyin .
SOLAR ENERGY, 2017, 150 :192-201
[36]   Melting and solidification processes of phase change material in evacuated tube solar collector with U-shaped spirally corrugated tube [J].
Olfian, Hassan ;
Ajarostaghi, Seyed Soheil Mousavi ;
Farhadi, Mousa ;
Ramiar, Abas .
APPLIED THERMAL ENGINEERING, 2021, 182
[37]   One-Sun CPC-type solar collectors with evacuated tubular receivers [J].
Osorio, T. ;
Horta, P. ;
Marcha, J. ;
Collares-Pereira, M. .
RENEWABLE ENERGY, 2019, 134 :247-257
[38]   A 50 year review of basic and applied research in compound parabolic concentrating solar thermal collector for domestic and industrial applications [J].
Pranesh, V ;
Velraj, R. ;
Christopher, S. ;
Kumaresan, V .
SOLAR ENERGY, 2019, 187 :293-340
[39]   SOLAR CONCENTRATORS WITH MAXIMAL CONCENTRATION FOR CYLINDRICAL ABSORBERS [J].
RABL, A .
APPLIED OPTICS, 1976, 15 (07) :1871-1873
[40]   PRACTICAL DESIGN CONSIDERATIONS FOR CPC SOLAR COLLECTORS [J].
RABL, A ;
GOODMAN, NB ;
WINSTON, R .