An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications

被引:362
作者
Chabinyc, ML
Chiu, DT
McDonald, JC
Stroock, AD
Christian, JF
Karger, AM
Whitesides, GM
机构
[1] Harvard Univ, Dept Chem & Biol Chem, Cambridge, MA 02138 USA
[2] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
关键词
D O I
10.1021/ac010423z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a prototype of an integrated fluorescence detection system that uses a microavalanche photodiode (mu APD) as the photodetector for microfluidic devices fabricated in poly(dimethylsiloxane) (PDMS). The prototype device consisted of a reusable detection system and a disposable microfluidic system that was fabricated using rapid prototyping. The first step of the procedure was the fabrication of microfluidic channels in PDMS and the encapsulation of a multimode optical fiber (100-mum core diameter) in the PDMS; the tip of the fiber was placed next to the side wall of one of the channels. The optical fiber was used to couple light into the microchannel for the excitation of fluorescent analytes. The photodetector, a prototype solid-state mu APD array, was embedded in a thick slab (1 cm) of PDMS. A thin (80 mum) colored polycarbonate filter was placed on the top of the embedded mu APD to absorb scattered excitation light before it reached the detector. The mu APD was placed below the microchannel and orthogonal to the axis of the optical fiber. The close proximity (similar to 200 mum) of the mu APD to the microchannel made it unnecessary to incorporate transfer optics; the pixel size of the mu APD (30 mum) matched the dimensions of the channels (50 mum). A blue light-emitting diode was used for fluorescence excitation. The mu APD was operated in Geiger mode to detect the fluorescence. The detection limit of the prototype (similar to 25 nM) was determined by finding the minimum detectable concentration of a solution of fluorescein. The device was used to detect the separation of a mixture of proteins and small molecules by capillary electrophoresis; the separation illustrated the suitability of this integrated fluorescence detection system for bioanalytical applications.
引用
收藏
页码:4491 / 4498
页数:8
相关论文
共 62 条
  • [1] Fabrication of topologically complex three-dimensional microfluidic systems in PDMS by rapid prototyping
    Anderson, JR
    Chiu, DT
    Jackman, RJ
    Cherniavskaya, O
    McDonald, JC
    Wu, HK
    Whitesides, SH
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3158 - 3164
  • [2] [Anonymous], 1984, OPTICAL RAD DETECTOR
  • [3] BARBER S, 1984, ELECTRON ENG, V56, P63
  • [4] Bayer H, 1996, J MICROCOLUMN SEP, V8, P479
  • [5] Microfluidic tectonics: A comprehensive construction platform for microfluidic systems
    Beebe, DJ
    Moore, JS
    Yu, Q
    Liu, RH
    Kraft, ML
    Jo, BH
    Devadoss, C
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (25) : 13488 - 13493
  • [6] Micromosaic immunoassays
    Bernard, A
    Michel, B
    Delamarche, E
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (01) : 8 - 12
  • [7] CHARACTERIZATION OF SILICON AVALANCHE PHOTODIODES FOR PHOTON-CORRELATION MEASUREMENTS .2. ACTIVE QUENCHING
    BROWN, RGW
    JONES, R
    RARITY, JG
    RIDLEY, KD
    [J]. APPLIED OPTICS, 1987, 26 (12): : 2383 - 2389
  • [8] CHARACTERIZATION OF SILICON AVALANCHE PHOTODIODES FOR PHOTON-CORRELATION MEASUREMENTS .1. PASSIVE QUENCHING
    BROWN, RGW
    RIDLEY, KD
    RARITY, JG
    [J]. APPLIED OPTICS, 1986, 25 (22): : 4122 - 4126
  • [9] Holographic refractive index detector for application in microchip-based separation systems
    Burggraf, N
    Krattiger, B
    de Mello, AJ
    de Rooij, NF
    Manz, A
    [J]. ANALYST, 1998, 123 (07) : 1443 - 1447
  • [10] DIRECT MEASUREMENT OF INTERFACIAL INTERACTIONS BETWEEN SEMISPHERICAL LENSES AND FLAT SHEETS OF POLY(DIMETHYLSILOXANE) AND THEIR CHEMICAL DERIVATIVES
    CHAUDHURY, MK
    WHITESIDES, GM
    [J]. LANGMUIR, 1991, 7 (05) : 1013 - 1025