Forward ultra-low emission for power plants via wet electrostatic precipitators and newly developed demisters: Filterable and condensable particulate matters

被引:52
作者
Liang, Yingguang [1 ]
Li, Qing [1 ,2 ]
Ding, Xiang [1 ]
Wu, Di [1 ]
Wang, Fengyang [3 ]
Otsuki, Tetsuya [1 ]
Cheng, Yi [1 ]
Shen, Tianxiao [1 ]
Li, Shuya [1 ]
Chen, Jianmin [1 ,2 ,4 ]
机构
[1] Fudan Univ, Dept Environm Sci & Engn, Shanghai 200433, Peoples R China
[2] Shanghai Inst Ecochongming, 3663 Northern Zhongshan Rd, Shanghai 200062, Peoples R China
[3] China Huaneng Clean Energy Technol Res Inst Co Lt, Beijing 102209, Peoples R China
[4] Chinese Acad Sci, Ctr Excellence Reg Atmospher Environm, Inst Urban Environm, Xiamen 361021, Peoples R China
基金
中国国家自然科学基金;
关键词
Coal-fired power plant; Pollutant emission and control; Particulate matter; Flue gas desulfurization; Wet electrostatic precipitator; SULFURIC-ACID AEROSOLS; FLUE-GAS; FIELD-MEASUREMENTS; CHEMICAL CHARACTERISTICS; INDUSTRIAL BOILERS; HAZE POLLUTION; REMOVAL; PM2.5; PERFORMANCE; SIZE;
D O I
10.1016/j.atmosenv.2020.117372
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Coal-fired power plants (CFPPs) install wet electrostatic precipitators (WESPs) or/and demisters as end control devices along with wet flue gas desulfurization (WFGD) systems to meet the ultra-low emission standards in China. This study comprehensively explores the influence of these end control devices on filterable particulate matter (FPM) and condensable particulate matter (CPM) emissions, based on field measurements and chemical analyses of collected samples. The field study was conducted in two typical CFPPs, one equipped with WESPs and the other with newly developed demisters (NDDs). With respect to FPM and filterable PM2.5, the WESP removal efficiency was 96. 3% and 92. 2%, respectively, and that of NDD was 62. 6% and 51. 5%, respectively. However, for some unconventional pollutants, the NDD removal efficiency was 60. 8% for CPM, which was higher than that of WESP (42. 10%); the removal efficiencies of HCl, SO3, and NH3 during the WESP were 78. 8%, 44. 11%, and 30. 5%, respectively, while they were 69. 16%, 58. 9%, and 60. 7%, respectively, when equipped with the NDD. Chemical composition analysis of the obtained samples revealed that the relative content of SO42 in FPM2.5 increased from 12-17% to 14-33% on using end control devices (WESP or NDD). Moreover, SO42 was the major ion component in CPM with relative ratios increasing from 15-35% to 21-59%. The mass ratio of FPM2.5 in FPMs, as well as the relative mass ratio of CPMs, in total particulate matter increased at the outlets of both control devices. The obtained results imply that both WESP and NDD effectively remove FPM and CPM to meet the ultra-low emission standards, respectively. Thus, more attention should be paid to emissions of CPM and FPM2.5 in pollution control technologies.
引用
收藏
页数:9
相关论文
共 42 条
[1]   Collection and Generation of Sulfuric Acid Aerosols in a Wet Electrostatic Precipitator [J].
Anderlohr, C. ;
Brachert, L. ;
Mertens, J. ;
Schaber, K. .
AEROSOL SCIENCE AND TECHNOLOGY, 2015, 49 (03) :144-151
[2]  
[Anonymous], 2001, HDB FUNDAMENTALS
[3]   Detection of Salmonella enterica subsp. enterica Serovar Cubana from Naturally Contaminated Chick Feed (vol 80, pg 1815, 2017) [J].
Benahmed, Faiza ;
Wang, Hua ;
Beaubrun, Junia Jean-Gilles ;
Gopinath, Gopal R. ;
Cheng, Chorng-Ming ;
Ayers, Sherry ;
Hanes, Darcy E. ;
Hammack, Thomas S. ;
Rasmussen, Mark ;
Davidson, Maureen K. .
JOURNAL OF FOOD PROTECTION, 2018, 81 (02) :170-170
[4]   An Integrated Risk Function for Estimating the Global Burden of Disease Attributable to Ambient Fine Particulate Matter Exposure [J].
Burnett, Richard T. ;
Pope, C. Arden, III ;
Ezzati, Majid ;
Olives, Casey ;
Lim, Stephen S. ;
Mehta, Sumi ;
Shin, Hwashin H. ;
Singh, Gitanjali ;
Hubbell, Bryan ;
Brauer, Michael ;
Anderson, H. Ross ;
Smith, Kirk R. ;
Balmes, John R. ;
Bruce, Nigel G. ;
Kan, Haidong ;
Laden, Francine ;
Pruess-Ustuen, Annette ;
Turner, Michelle C. ;
Gapstur, Susan M. ;
Diver, W. Ryan ;
Cohen, Aaron .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2014, 122 (04) :397-403
[5]   Characterization of Condensable Particulate Matter Emissions in Agricultural Diesel Engines Using a Dilution-Based Sampling Train [J].
Cano, M. ;
Vega, F. ;
Palomo, D. ;
Serrano, J. ;
Navarrete, B. .
ENERGY & FUELS, 2019, 33 (02) :779-787
[6]   Characterization of Emissions of Condensable Particulate Matter in Clinker Kilns Using a Dilution Sampling System [J].
Cano, M. ;
Vega, F. ;
Navarrete, B. ;
Plumed, A. ;
Camino, J. A. .
ENERGY & FUELS, 2017, 31 (08) :7831-7838
[7]   Status of Flue Gas Desulphurisation (FGD) systems from coal-fired power plants: Overview of the physic-chemical control processes of wet limestone FGDs [J].
Cordoba, Patricia .
FUEL, 2015, 144 :274-286
[8]   Effect of a Wet Flue Gas Desulphurization System on the Emission of PM2.5 from Coal-Fired Power Plants [J].
Deng J.-G. ;
Ma Z.-Z. ;
Li Z. ;
Duan L. ;
Jiang J.-K. .
Huanjing Kexue/Environmental Science, 2019, 40 (08) :3457-3462
[9]   Unexpectedly Increased Particle Emissions from the Steel Industry Determined by Wet/Semidry/Dry Flue Gas Desulfurization Technologies [J].
Ding, Xiang ;
Li, Qing ;
Wu, Di ;
Liang, Yingguang ;
Xu, Xianmang ;
Xie, Guangzhao ;
Wei, Yaqi ;
Sun, Hao ;
Zhu, Chao ;
Fu, Hongbo ;
Chen, Jianmin .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (17) :10361-10370
[10]   Critical review of condensable particulate matter [J].
Feng, Yupeng ;
Li, Yuzhong ;
Cui, Lin .
FUEL, 2018, 224 :801-813