Preoperative radiotherapy without femoral shielding for prevention of heterotopic ossification in hydroxyapatite-coated hip prostheses

被引:5
|
作者
Taussky, D
Cserhati, M
Pescia, R
机构
[1] Triemli Hosp, Dept Radiotherapy, CH-8063 Zurich, Switzerland
[2] Triemli Hosp, Dept Orthoped Surg, CH-8063 Zurich, Switzerland
关键词
D O I
10.1007/s004020000223
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Twenty-seven consecutive patients at high risk of developing heterotopic ossifications (HO) after implantation of a hydroxyapatite (HA)-coated hip prosthesis were irradiated with a single dose of 7 Gy, at least 4 h before the operation. The femoral stem was not shielded during radiotherapy (RT). After a median follow-up of 14.8 months, no clinically significant HO could be found, while 12 (52%) patients in this high-risk population had only minor HO (grade I). No reoperation was needed, and no evidence of prosthesis migration was observed. We conclude that single-dose, preoperative RT for HA-coated hip prosthesis can effectively inhibit HO. Not blocking the femoral stem does not result in prosthesis migration.
引用
收藏
页码:271 / 273
页数:3
相关论文
共 50 条
  • [1] Preoperative radiotherapy without femoral shielding for prevention of heterotopic ossification in hydroxyapatite-coated hip prostheses
    D. Taussky
    M. Cserhati
    R. Pescia
    Archives of Orthopaedic and Trauma Surgery, 2001, 121 : 271 - 273
  • [2] HYDROXYAPATITE-COATED TOTAL HIP PROSTHESES
    WICKI, O
    MIKIC, S
    GERBER, P
    HELVETICA CHIRURGICA ACTA, 1990, 57 (01) : 107 - 115
  • [3] BIOCOMPATIBILITY OF HYDROXYAPATITE-COATED HIP PROSTHESES
    SANTAVIRTA, S
    NORDSTROM, D
    YLINEN, P
    KONTTINEN, YT
    SILVENNOINEN, T
    ROKKANEN, P
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1991, 110 (06) : 288 - 292
  • [4] Heterotopic ossification after uncemented hydroxyapatite-coated primary total hip arthroplasty
    Kasetti, RJ
    Shetty, AA
    Rand, C
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 1038 - 1042
  • [5] Osteointegration of hydroxyapatite-coated stems of femoral prostheses
    D. C. R. Hardy
    P. Frayssinet
    P. E. Delince
    European Journal of Orthopaedic Surgery & Traumatology, 1999, 9 (2) : 75 - 81
  • [6] Analysis of retrieved hydroxyapatite-coated hip prostheses
    Gross, KA
    Walsh, W
    Swarts, E
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2004, 13 (02) : 190 - 199
  • [7] Analysis of retrieved hydroxyapatite-coated hip prostheses
    K. A. Gross
    W. Walsh
    E. Swarts
    Journal of Thermal Spray Technology, 2004, 13 : 190 - 199
  • [8] Total hip arthroplasty with hydroxyapatite-coated prostheses
    Jaffe, WL
    Scott, DF
    JOINT ARTHROPLASTY, 1999, : 159 - 187
  • [9] Total hip arthroplasty with hydroxyapatite-coated prostheses
    Jaffe, WL
    Scott, DF
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (12): : 1918 - 1934
  • [10] RADIOGRAPHIC PATTERNS IN TOTAL HIP-ARTHROPLASTY - HYDROXYAPATITE-COATED AND UNCOATED FEMORAL STEM PROSTHESES
    FOX, MG
    RAK, KM
    LISECKI, EJ
    CASTELLO, PH
    RADIOLOGY, 1995, 197 : 396 - 396