High strain mechanical loading rapidly induces tendon apoptosis: an ex vivo rat tibialis anterior model

被引:71
|
作者
Scott, A
Khan, KM
Heer, J
Cook, JL
Lian, O
Duronio, V
机构
[1] Univ British Columbia, Dept Family Practice, Vancouver, BC V6T 1V6, Canada
[2] Univ British Columbia, Sch Human Kinet, Vancouver, BC V6T 1V6, Canada
[3] Univ Melbourne, Parkville, Vic 3052, Australia
[4] La Trobe Univ, Melbourne, Vic, Australia
[5] Oslo Sports Trauma Res Ctr, Oslo, Norway
关键词
D O I
10.1136/bjsm.2004.015164
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: The role of apoptosis, or programmed cell death, has only recently been explored in tendon. Objective: To investigate the development of apoptosis after high strain loading of rat tendon. Methods: The right tibialis anterior tendons of three rats were prepared for mechanical loading, and left tendons were prepared identically as non-loaded controls. Tendon was loaded with 20% strain for six hours using a 1 Hz longitudinal sine wave signal. The following were used to assess apoptosis: (a) a monoclonal mouse antibody (F7-26) to label single stranded DNA breaks; (b) a rabbit polyclonal antibody that specifically recognises the cleaved form of caspase-3. Results: Light microscopy confirmed that the high strain protocol induced a stretch overload injury. Control tendons showed little or no staining with the F7-26 antibody, but the loaded tendons displayed numerous apoptotic cells. The percentage of apoptotic cells (20%) in the loaded tendon was significantly greater than in the control tendon (1%) (p = 0.000). The labelled cells colocalised with abnormal nuclear morphology, including nuclear fragmentation. The staining against cleaved caspase-3 was positive in loaded tendons only, and localised both to nucleus and cytoplasm. Conclusion: This experiment extends knowledge of human tendon apoptosis by showing that apoptosis can occur in response to short term, high strain mechanical loading. This is the first report of mechanical loading of intact tendon causing excessive apoptosis.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Mechanical strain induces ex vivo expansion of periosteum
    Walker, Mary M.
    Baumann, Molly E.
    Alexander, John H.
    Blackstone, Britani N.
    Morgan, Christopher B.
    Scharschmidt, Thomas J.
    Powell, Heather M.
    PLOS ONE, 2022, 17 (12):
  • [2] Focused Ultrasound Mechanical Disruption of Ex Vivo Rat Tendon
    Smallcomb, Molly
    Elliott, Jacob
    Khandare, Sujata
    Butt, Ali A.
    Vidt, Meghan E.
    Simon, Julianna C.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (09) : 2981 - 2986
  • [3] Gap junctions regulate responses of tendon cells ex vivo to mechanical loading
    Banes, AJ
    Weinhold, P
    Yang, X
    Tsuzaki, M
    Bynum, D
    Bottlang, M
    Brown, T
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (367) : S356 - S370
  • [4] Comparison of mechanical properties of rat tibialis anterior tendon evaluated using two different approaches
    Wu, JZ
    Brumfield, A
    Miller, GR
    Metheny, R
    Cutlip, RG
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2004, 14 (01) : 13 - 22
  • [5] An ex vivo animal model to study the effect of transverse mechanical loading on skeletal muscle
    Sargent, Marisa
    Wark, Alastair W.
    Day, Sarah
    Buis, Arjan
    COMMUNICATIONS BIOLOGY, 2024, 7 (01)
  • [6] Establishment of an ex vivo cartilage damage model by combined collagenase treatment and mechanical loading
    Wen, Liru
    Grad, Sibylle
    Creemers, Laura B.
    Stoddart, Martin J.
    ARTHRITIS RESEARCH & THERAPY, 2025, 27 (01)
  • [7] An ex vivo animal model to study the effect of transverse mechanical loading on skeletal muscle
    Marisa Sargent
    Alastair W. Wark
    Sarah Day
    Arjan Buis
    Communications Biology, 7
  • [8] INHIBITION OF APOPTOSIS EXACERBATES FATIGUE-DAMAGE TENDON INJURIES IN AN IN VIVO RAT MODEL
    Bell, R.
    Robles-Harris, M. A.
    Anderson, M.
    Laudier, D.
    Schaffler, M. B.
    Flatow, E. L.
    Andarawis-Puri, N.
    EUROPEAN CELLS & MATERIALS, 2018, 36 : 44 - 56
  • [9] Overload in a Rat In Vivo Model of Synergist Ablation Induces Tendon Multiscale Structural and Functional Degeneration
    Bloom, Ellen T.
    Lin, Lily M. M.
    Locke, Ryan C.
    Giordani, Alyssa
    Krassan, Erin
    Peloquin, John M.
    Silbernagel, Karin Graevare
    Parreno, Justin
    Santare, Michael H.
    Killian, Megan L.
    Elliott, Dawn M.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (08):
  • [10] The relationships between cyclic fatigue loading, changes in initial mechanical properties, and the in vivo temporal mechanical response of the rat patellar tendon
    Andarawis-Puri, Nelly
    Sereysky, Jedd B.
    Jepsen, Karl J.
    Flatow, Evan L.
    JOURNAL OF BIOMECHANICS, 2012, 45 (01) : 59 - 65