Relation between bone density and primary implant stability

被引:63
作者
Farre-Pages, Nuria [1 ]
Auge-Castro, Ma Luisa [1 ]
Alaejos-Algarra, Fernando [1 ]
Mareque-Bueno, Javier [1 ]
Ferres-Padro, Eduard [1 ]
Hernandez-Alfaro, Federico [1 ]
机构
[1] Univ Int Catalunya, Fac Dent, Med Surg & Oral Implantol Dept, Barcelona 08195, Spain
来源
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL | 2011年 / 16卷 / 01期
关键词
Hounsfield unit; bone quality; implant stability; computerized tomography (CT scan); dental im-; COMPUTERIZED-TOMOGRAPHY VALUES; RESONANCE FREQUENCY; CUTTING TORQUE; ASSESSMENTS; SITES; CLASSIFICATION; PLACEMENT;
D O I
10.4317/medoral.16.e62
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). Materials and Methods: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded. Results: A statistically significant relationship was observed between bone quality density and location with ISQ values. Conclusions: This research demonstrates a strong relationship between the bone density values from computerized tomography and the location in the maxillaries. A correlation exists between bone quality, according to the Lekholm & Zarb classification, and Hu computerized tomography values. The primary implant stability measured with resonance frequency analysis depends on bone density values, bone quality and implant location.
引用
收藏
页码:E62 / E67
页数:6
相关论文
共 20 条
  • [1] Aranyarachkul P, 2005, INT J ORAL MAX IMPL, V20, P416
  • [2] Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible
    Beer, A
    Gahleitner, A
    Holm, A
    Tschabitscher, M
    Homolka, P
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (05) : 616 - 620
  • [3] da Cunha HA, 2004, INT J ORAL MAX IMPL, V19, P578
  • [4] Biological factors contributing to failures of osseointegrated oral implants - (II). Etiopathogenesis
    Esposito, M
    Hirsch, JM
    Lekholm, U
    Thomsen, P
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (03) : 721 - 764
  • [5] Friberg B, 1999, INT J ORAL MAX SURG, V28, P266, DOI 10.1016/S0901-5027(99)80156-8
  • [6] Friberg Bertil, 2003, Clin Implant Dent Relat Res, V5, P71, DOI 10.1111/j.1708-8208.2003.tb00186.x
  • [7] Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach
    Huang, HM
    Lee, SY
    Yeh, CY
    Lin, CT
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (01) : 65 - 74
  • [8] Ikumi N, 2005, INT J ORAL MAX IMPL, V20, P253
  • [9] JEMT T, 1989, International Journal of Oral and Maxillofacial Implants, V4, P211
  • [10] Jemt T, 1995, Int J Oral Maxillofac Implants, V10, P303