Utility of the surface electrocardiogram for confirming right ventricular septal pacing: validation using electroanatomical mapping

被引:37
作者
Burri, Haran [1 ]
Park, Chan-il [1 ]
Zimmermann, Marc [2 ]
Gentil-Baron, Pascale [1 ]
Stettler, Carine [1 ]
Sunthorn, Henri [1 ]
Domenichini, Giulia [1 ]
Shah, Dipen [1 ]
机构
[1] Univ Hosp, Serv Cardiol, CH-1211 Geneva 14, Switzerland
[2] La Tour Hosp, Serv Cardiol, Geneva, Switzerland
来源
EUROPACE | 2011年 / 13卷 / 01期
关键词
Pacing; Ventricle; Interventricular septum; Electrocardiogram; Electroanatomical mapping; OUTFLOW TRACT TACHYCARDIA; ATRIAL-FIBRILLATION; SITE; ACTIVATION; ABLATION; SEQUENCE; LOCATION; ORIGIN; WALL;
D O I
10.1093/europace/euq332
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims When targeting the interventricular septum during pacemaker implantation, the lead may inadvertently be positioned on the anterior wall due to imprecise fluoroscopic landmarks. Surface electrocardiogram (ECG) criteria of the paced QRS complex (e.g. negativity in lead I) have been proposed to confirm a septal position, but these criteria have not been properly validated. Our aim was to investigate whether the paced QRS complex may be used to confirm septal lead position. Methods Anatomical reconstruction of the right ventricle was performed using a NavX(R) system in 31 patients (70 +/- 11 years, 26 males) to validate pacing sites. Surface 12-lead ECGs were analysed by digital callipers and compared while pacing from a para-Hissian position, from the mid-septum, and from the anterior free wall. Results Duration of the QRS complex was not significantly shorter when pacing from the mid-septum compared with the other sites. QRS axis was significantly less vertical during mid-septal pacing (18 +/- 518) compared with para-Hissian (38 +/- 378, P = 0.028) and anterior (53 +/- 558, P = 0.003) pacing, and QRS transition was intermediate (4.8 +/- 1.3 vs. 3.8 +/- 1.3, P < 0.001, and vs. 5.4 +/- 0.9, P = 0.045, respectively), although no cut-offs could reliably distinguish sites. A negative QRS or the presence of a q-wave in lead I tended to be more frequent with anterior than with mid-septal pacing (9/31 vs. 3/31, P = 0.2 and 8/31 vs. 1/31, P = 1.0, respectively). Conclusion No single ECG criterion could reliably distinguish pacing the mid-septum from the anterior wall. In particular, a negative QRS complex in lead I is an inaccurate criterion for validating septal pacing.
引用
收藏
页码:82 / 86
页数:5
相关论文
共 50 条
[31]   Right Ventricular Septal Pacing Using a Thin Lumenless Pacing Lead and Delivery System with a Deflectable Catheter Long-Term Outcomes [J].
Suzuki, Takeya ;
Fujino, Tadashi ;
Shinohara, Masaya ;
Koike, Hideki ;
Kinoshita, Toshio ;
Yuzawa, Hitomi ;
Ikeda, Takanori .
INTERNATIONAL HEART JOURNAL, 2018, 59 (06) :1253-1260
[32]   Implications of right ventricular septal pacing for medium-term prognosis: Propensity-matched analysis [J].
Mizukami, Akira ;
Matsue, Yuya ;
Naruse, Yoshihisa ;
Kowase, Shinya ;
Kurosaki, Kenji ;
Suzuki, Makoto ;
Matsumura, Akihiko ;
Nogami, Akihiko ;
Aonuma, Kazutaka ;
Hashimoto, Yuji .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 220 :214-218
[33]   Electroanatomical Voltage Mapping to Distinguish Right-Sided Cardiac Sarcoidosis From Arrhythmogenic Right Ventricular Cardiomyopathy [J].
Hoogendoorn, Jarieke C. ;
Sramko, Marek ;
Venlet, Jeroen ;
Siontis, Konstantinos C. ;
Kumar, Saurabh ;
Singh, Robin ;
Nakajima, Ikutaro ;
Piers, Sebastiaan R. D. ;
Silva, Marta de Riva ;
Glashan, Claire A. ;
Crawford, Thomas ;
Tedrow, Usha B. ;
Stevenson, William G. ;
Bogun, Frank ;
Zeppenfeld, Katja .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (06) :696-707
[34]   Ventricular Functional Analysis in Congenital Complete Heart Block Using Speckle Tracking: Left Ventricular Epicardial Compared to Right Ventricular Septal Pacing [J].
Rivera, Diana Milagros Torpoco ;
Sriram, Chenni ;
Karpawich, Peter P. P. ;
Aggarwal, Sanjeev .
PEDIATRIC CARDIOLOGY, 2023, 44 (05) :1160-1167
[35]   Machine learning for distinguishing right from left premature ventricular contraction origin using surface electrocardiogram features [J].
Zhao, Wei ;
Zhu, Rui ;
Zhang, Jian ;
Mao, Yangming ;
Chen, Hongwu ;
Ju, Weizhu ;
Li, Mingfang ;
Yang, Gang ;
Gu, Kai ;
Wang, Zidun ;
Liu, Hailei ;
Shi, Jiaojiao ;
Jiang, Xiaohong ;
Kojodjojo, Pipin ;
Chen, Minglong ;
Zhang, Fengxiang .
HEART RHYTHM, 2022, 19 (11) :1781-1789
[36]   Right Ventricular Septal Pacing vs. Right Ventricular Apical Pacing Following Atrioventricular Node Ablation: A 10-Year Follow-up [J].
Eysenck, William ;
Sulke, Neil ;
Gallagher, Angela ;
Jouhra, Fadi ;
Patel, Nikhil ;
Furniss, Stephen ;
Veasey, Rick .
INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2018, 12 (03) :90-98
[37]   Biventricular Function is Impaired in Right Ventricular Septal Pacing-A Prospective Study Using Myocardial Strain Imaging [J].
Toner, Liam ;
Chen, Janet X. C. ;
Ramchand, Jay ;
Srivastava, Piyush ;
O'Donnell, David ;
Calafiore, Paul ;
Jones, Elizabeth .
HEART LUNG AND CIRCULATION, 2023, 32 (03) :373-378
[38]   The paced electrocardiogram cannot be used to identify left and right ventricular pacing sites in cardiac resynchronization therapy: validation by cardiac computed tomography [J].
Sommer, Anders ;
Kronborg, Mads Brix ;
Witt, Christoffer Tobias ;
Norgaard, Bjarne Linde ;
Nielsen, Jens Cosedis .
EUROPACE, 2015, 17 (03) :432-438
[39]   Electrocardiographic identification of prior myocardial infarction during right ventricular pacing - Effect of septal versus apical pacing [J].
Tzeis, Stylianos ;
Andrikopoulos, George ;
Asbach, Stefan ;
Semmler, Verena ;
Lennerz, Carsten ;
Solzbach, Ulrich ;
Vrazic, Hrvoje ;
Kloppe, Axel ;
Klein, Norbert ;
Pastromas, Sokratis ;
Biermann, Juergen ;
Kolb, Christof .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (03) :977-981
[40]   Right Ventricular Septal Pacing Preserves Global Left Ventricular Longitudinal Function in Comparison With Apical Pacing - Analysis of Speckle Tracking Echocardiography [J].
Inoue, Katsuji ;
Okayama, Hideki ;
Nishimura, Kazuhisa ;
Saito, Makoto ;
Yoshii, Toyofumi ;
Hiasa, Go ;
Sumimoto, Takumi ;
Inaba, Shinji ;
Suzuki, Jun ;
Ogimoto, Akiyoshi ;
Funada, Jun-ichi ;
Higaki, Jitsuo .
CIRCULATION JOURNAL, 2011, 75 (07) :1609-1615