Effects of magnetic resonance imaging in patients with implanted deep brain stimulation systems

被引:21
作者
Fraix, Valerie [1 ,3 ]
Chabardes, Stephan [1 ,3 ]
Krainik, Alexandre [2 ,3 ]
Seigneuret, Eric [1 ,3 ]
Grand, Sylvie [2 ,3 ]
Le Bas, Jean-Francois [2 ,3 ]
Krack, Paul [1 ,3 ]
Benabid, Alim-Louis [1 ,3 ,4 ]
Pollak, Pierre [1 ,3 ]
机构
[1] Univ Hosp Grenoble, Magnet Resonance Imaging Unit, Dept Neurol & Neurosurg, Grenoble, France
[2] Univ Hosp Grenoble, Magnet Resonance Imaging Unit, Neuroradiol Dept, Grenoble, France
[3] Univ Grenoble 1, Grenoble Neurosci Inst, INSERM, U836, Grenoble, France
[4] CEA, Direct Rech Technol, Lab Elect & Technol Informat, Grenoble, France
关键词
deep brain stimulation; magnetic resonance imaging; neurostimulator; movement disorder; NEUROSTIMULATION SYSTEMS; IN-VITRO; MRI; ELECTRODES;
D O I
10.3171/2010.1.JNS09951
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The aim of this study was to study the effects of MR imaging on the electrical settings of deep brain stimulation (DBS) systems and their clinical consequences. Methods. The authors studied the effects of 1.5-T MR imaging on the electrical settings of implanted DBS systems, including 1 or more monopolar or quadripolar leads, extension leads, and single- or dual-channel implantable pulse generators (IPGs). The IPG was switched off during the procedure and the voltage was set to 0. The impedances were checked before and after MR imaging. Results. Five hundred seventy patients were treated with DBS for movement disorders and underwent brain MR imaging after lead implantation and before IPG implantation. None of the patients experienced any adverse events. Thirty-one of these patients underwent 61 additional MR imaging sessions after the entire DBS system had been implanted. The authors report neither local cutaneous nor neurological disorders during or after the MR imaging session. No change in the IPG settings occurred when the magnet reed switch function remained disabled during the procedure. Conclusions. This study demonstrates that 1.5-T MR imaging can be performed safely with continuous monitoring in patients with a DBS system. The ability to disable the magnet reed switch function of the IPG prevents any change in the electrical settings and thus any side effects. The increasing number of DBS indications and the widespread use of MR imaging indicates the need for defining safety guidelines for the use of MR imaging in patients with implanted neurostimulators. (DOI: 10.3171/2010.1.JNS09951)
引用
收藏
页码:1242 / 1245
页数:4
相关论文
共 18 条
[1]   Neurostimulation systems: Assessment of magnetic field interactions associated with 1.5-and 3-Tesla MR systems [J].
Baker, KB ;
Nyenhuis, JA ;
Hrdlicka, G ;
Rezai, AR ;
Tkach, JA ;
Shellock, FG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (01) :72-77
[2]   REDUCTION OF MAGNETIC RESONANCE IMAGING-RELATED HEATING IN DEEP BRAIN STIMULATION LEADS USING A LEAD MANAGEMENT DEVICE [J].
Baker, Kenneth B. ;
Tkach, Jean ;
Hall, John D. ;
Nyenhuis, John A. ;
Shellock, Frank G. ;
Rezai, Ali R. .
NEUROSURGERY, 2005, 57 (04) :392-396
[3]   Bilateral neuro stimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain [J].
Bhidayasiri, R ;
Bronstein, JM ;
Sinha, S ;
Krahl, SE ;
Ahn, S ;
Behnke, EJ ;
Cohen, MS ;
Frysinger, R ;
Shellock, FG .
MAGNETIC RESONANCE IMAGING, 2005, 23 (04) :549-555
[4]  
COUBES P, 2008, OPEN MAGN RESON J, V1, P1
[5]   Safety of MRI at 1.5 Tesla in patients with implanted sacral nerve neurostimulator [J].
Elkelini, Mohamed S. ;
Hassouna, Mady M. .
EUROPEAN UROLOGY, 2006, 50 (02) :311-316
[6]   Active deep brain stimulation during MRI: A feasibility study [J].
Georgi, JC ;
Stippich, C ;
Tronnier, VM ;
Heiland, S .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) :380-388
[7]   Prevention of mechanical failures in implanted spinal cord stimulation systems [J].
Henderson, JM ;
Oakley, JC ;
Schade, CM ;
Sasaki, J ;
Caraway, DL .
NEUROSURGERY, 2005, 57 (02) :414-414
[8]   Implanted deep brain stimulator and 1.0-Tesla magnetic resonance imaging [J].
Kovacs, Norbert ;
Nagy, Ferenc ;
Kover, Ferenc ;
Feldmann, Adam ;
Llumiguano, Carlos ;
Janszky, Jozsef ;
Kotek, Gyula ;
Doczi, Tamas ;
Balas, Istvan .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) :1409-1412
[9]   Magnetic resonance imaging of implanted deep brain stimulators: Experience in a large series [J].
Larson, Paul S. ;
Richardson, R. Mark ;
Starr, Philip A. ;
Martin, Alastair J. .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2008, 86 (02) :92-100
[10]   DBS and diathermy interaction induces severe CNS damage [J].
Nutt, JG ;
Anderson, VC ;
Peacock, JH ;
Hammerstad, JP ;
Burchiel, KJ .
NEUROLOGY, 2001, 56 (10) :1384-1386