A surface plasmon resonance system for the measurement of glucose in aqueous solution

被引:102
作者
Lam, WW [1 ]
Chu, LH
Wong, CL
Zhang, YT
机构
[1] Chinese Univ Hong Kong, Joint Res Ctr Biomed Engn, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
[2] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
关键词
surface plasmon resonance (SPR); glucose measurement; refractive index; wavelength modulation;
D O I
10.1016/j.snb.2004.04.088
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a surface plasmon resonance (SPR) system is proposed as an alternative approach for glucose measurement. The developed SPR system, which is based on wavelength interrogation technique, has a high detection resolution of 8.67 x 10(-6) refractive index unit (RIU), equivalent to 6.23 mg/dL of glucose in water. The experimental results show that the proposed SPR system is capable of measuring the glucose at the concentration levels in physiological ranges, potentially leading to its further development towards a minimal-invasive glucose measurement of interstitial fluid. (c) 2004 Published by Elsevier B.V.
引用
收藏
页码:138 / 143
页数:6
相关论文
共 19 条
[1]   A surface plasmon resonance sensor probe based on retro-reflection [J].
Cahill, CP ;
Johnston, KS ;
Yee, SS .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (02) :161-166
[2]   Measurement of wavelength shift by using surface plasmon resonance heterodyne interferometry [J].
Chen, KH ;
Hsu, CC ;
Su, DC .
OPTICS COMMUNICATIONS, 2002, 209 (1-3) :167-172
[3]   Surface plasmon resonance sensor based on the measurement of differential phase [J].
Ho, HP ;
Lam, WW ;
Wu, SY .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (10) :3534-3539
[4]   Application of white light-emitting diode to surface plasmon resonance sensors [J].
Ho, HP ;
Wu, SY ;
Yang, M ;
Cheung, AC .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 80 (02) :89-94
[5]   Surface plasmon resonance sensors: review [J].
Homola, J ;
Yee, SS ;
Gauglitz, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :3-15
[6]   Surface plasmon resonance sensors based on diffraction gratings and prism couplers: sensitivity comparison [J].
Homola, J ;
Koudela, I ;
Yee, SS .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :16-24
[7]  
KAMATI VV, BIOORG MED CHEM LETT, V12, pP3373
[8]  
Khalil OS, 1999, CLIN CHEM, V45, P165
[9]   INFLUENCE OF GLUCOSE-CONCENTRATION ON LIGHT-SCATTERING IN TISSUE-SIMULATING PHANTOMS [J].
KOHL, M ;
COPE, M ;
ESSENPREIS, M ;
BOCKER, D .
OPTICS LETTERS, 1994, 19 (24) :2170-2172
[10]  
MARIER JS, 1994, OPT LETT, V19, P2062