Correlation Between the 2-Dimensional Notch Width and the 3-Dimensional Notch Volume: A Cadaveric Study

被引:22
|
作者
Van Eck, Carola F. [2 ]
Martins, Cesar A. Q.
Kopf, Sebastian
Lertwanich, Pisit
Fu, Freddie H.
Tashman, Scott [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Orthopaed Res Labs, Med Ctr, Pittsburgh, PA 15203 USA
[2] Univ Amsterdam, Acad Med Ctr, Orthopaed Res Ctr Amsterdam, NL-1105 AZ Amsterdam, Netherlands
来源
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY | 2011年 / 27卷 / 02期
关键词
ANTERIOR CRUCIATE LIGAMENT; FEMORAL INTERCONDYLAR NOTCH; RECONSTRUCTION; INJURIES; STENOSIS; TEARS; RISK; RADIOGRAPHY; PLAYERS; RUPTURE;
D O I
10.1016/j.arthro.2010.06.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to compare the size of the entrance of the notch, as measured arthroscopically (2-dimensionally), with the volume of the notch as measured by use of computed tomography (CT) (3-dimensionally). Methods: For 20 cadaveric knees, the dimensions of the notch entrance were measured arthroscopically, and the notch volume was measured by use of CT. The correlation between the size of the notch entrance and the notch volume was calculated. Intraobserver reliability and interobserver reliability of the arthroscopic and CT measurements were tested. Results: The Pearson correlation coefficients between CT-assessed notch volume and arthroscopically assessed notch height and width at the bottom, middle, and top of the notch were 0.603, 0.506, 0.551, and 0.642, respectively. The intraobserver reliability and interobserver reliability of the arthroscopic measurements were above 0.962 and 0.819, respectively, and 0.983 and 0.975, respectively, for the CT measurements. Conclusions: There were only moderate correlations between arthroscopic notch measurements and notch volume. Both the arthroscopic and CT measurements proved highly reliable. Clinical Relevance: The moderate correlation between 2-dimensional and 3-dimensional notch measurements warrants caution concerning the use of either measurement for assessing risk for anterior cruciate ligament injury or as justification for notchplasty until studies between the relation of 3-dimensional notch volume and anterior cruciate ligament injury are conducted.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [21] Clinical application of 3-dimensional tissue volume assessment using CloudCompare
    Ma, Jolande
    Aung, Yee Mon
    Manzie, Timothy
    Cheng, Kai
    Dunn, Masako
    Mukherjee, Payal
    Clark, Jonathan
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2023, 61 (08): : 567 - 570
  • [22] Kinematics of Rugby Tackling A Pilot Study With 3-dimensional Motion Analysis
    Kawasaki, Takayuki
    Tanabe, Yasumasa
    Tanaka, Hiroshi
    Murakami, Kenji
    Maki, Nobukazu
    Ozaki, Hiroki
    Hirayama, Daisaku
    Kunda, Masahiro
    Nobuhara, Katsuya
    Okuwaki, Toru
    Kaneko, Kazuo
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2018, 46 (10): : 2514 - 2520
  • [23] Visual Assessment of 2-Dimensional Levels Within 3-Dimensional Pathology Data Sets of Prostate Needle Biopsies Reveals Substantial Spatial Heterogeneity
    Koyuncu, Can
    Janowczyk, Andrew
    Farre, Xavier
    Pathak, Tilak
    Mirtti, Tuomas
    Fernandez, Pedro L.
    Pons, Laura
    Reder, Nicholas P.
    Sera, Robert
    Chow, Sarah S. L.
    Viswanathan, Vidya S.
    Glaser, Adam K.
    True, Lawrence D.
    Liu, Jonathan T. C.
    Madabhushi, Anant
    LABORATORY INVESTIGATION, 2023, 103 (12)
  • [24] Real-time 3-dimensional color Doppler flow of mitral and tricuspid regurgitation: Feasibility and initial quantitative comparison with 2-dimensional methods
    Sugeng, Lissa
    Weinert, Lynn
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (09) : 1050 - 1057
  • [25] Estimating Implant Volume and Mastectomy-Specimen Volume by Measuring Breast Volume With a 3-Dimensional Scanner
    Utsunomiya, Hiroki
    Kusano, Taro
    Sato, Nobuhiro
    Yoshimoto, Shinya
    ANNALS OF PLASTIC SURGERY, 2017, 79 (01) : 79 - 81
  • [26] Assessing the Accuracy of a 3-Dimensional Surface Imaging System in Breast Volume Estimation
    Kwong, Jeffrey W.
    Tijerina, Jonathan David
    Choi, Sara
    Luan, Anna
    Feng, Carol L.
    Nguyen, Dung H.
    Lee, Gordon K.
    Nazerali, Rahim S.
    ANNALS OF PLASTIC SURGERY, 2020, 84 : S311 - S317
  • [27] 3-DIMENSIONAL LITHOGRAPHIC MODEL-BUILDING FROM VOLUME DATA SETS
    PALSER, R
    JAMIESON, R
    SUTHERLAND, JB
    SKIBO, L
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1990, 41 (06): : 339 - 341
  • [28] Quantitative Assessment of the Coracoacromial and the Coracoclavicular Ligaments With 3-Dimensional Mapping of the Coracoid Process Anatomy: A Cadaveric Study of Surgically Relevant Structures
    Chahla, Jorge
    Marchetti, Daniel Cole
    Moatshe, Gilbert
    Ferrari, Marcio B.
    Sanchez, George
    Brady, Alex W.
    Pogorzelski, Jonas
    Lebus, George F.
    Millett, Peter J.
    LaPrade, Robert F.
    Provencher, Matthew T.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (05): : 1403 - 1411
  • [29] The Superficial Femoral Artery Flap: A 3-Dimensional Anatomical Study
    El-Hadi, Hadal
    Morris, Steven
    Alkhawaji, Ali
    PLASTIC SURGERY, 2017, 25 (03) : 188 - 193
  • [30] New 3-Dimensional Volumetric Ultrasound Method for Accurate Quantification of Atherosclerotic Plaque Volume
    Lopez-Melgar, Beatriz
    Mass, Virgina
    Nogales, Paula
    Sanchez-Gonzalez, Javier
    Entrekin, Robert
    Collet-Billon, Antoine
    Rossello, Xavier
    Fernandez-Friera, Leticia
    Fernandez-Ortiz, Antonio
    Sanz, Javier
    Bentzon, Jacob F.
    Bueno, Hector
    Ibanez, Borja
    Fuster, Valentin
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (06) : 1124 - 1135