摘要
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD) was developed for extraction and determination of thiamphenicol (THA) in honey. A mixture of extraction solvent (30 μL 1,1,2,2-tetrachloroethane) and dispersive solvent (1.0 mL of acetonitrile) was rapidly injected into 5.00 mL sample solution for the formation of cloudy solution. The analyte in the sample was extracted into the fine droplets of C2H2Cl 4. After extraction, phase separation was performed by centrifugation, and the enriched analyte in the sedimented phase was determined by HPLC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume, and salt effect, were investigated and optimized. Under the optimum extraction condition, the method yielded a linear calibration curve in the concentration range from 3 to 2000 μg/kg for target analyte. The enrichment factors for THA was 87.9, and the limit of detection (S/N = 3) was 0.1 μg/kg. The relative standard deviation for the extraction of 10 μg/kg of THA was 6.2% (n = 6). The main advantages of DLLME-HPLC method are simplicity of operation, rapidity, low cost, high enrichment factor, high recovery, good repeatability, and extraction solvent volume at the μL level. Honey samples were successfully analyzed using the proposed method.
引用
收藏
页码:450 / 455
页数:6
相关论文
共 22 条
[1]   Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]  
[Anonymous], TRENDS ANAL CHEM
[3]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[4]   Application of on-line solid-phase extraction-gas chromatography-mass spectrometry to the determination of endocrine disruptors in water samples [J].
Brossa, L ;
Marcé, RM ;
Borrull, F ;
Pocurull, E .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :287-294
[5]   Modified pencil lead as a new fiber for solid-phase microextraction [J].
Djozan, D ;
Assadi, Y .
CHROMATOGRAPHIA, 2004, 60 (5-6) :313-317
[6]   Anodized aluminum wire as a solid-phase microextraction fiber [J].
Djozan, D ;
Assadi, Y ;
Haddadi, SH .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :4054-4058
[7]   A surface plasmon resonance biosensor assay for the simultaneous determination of thiamphenicol, florefenicol, florefenicol amine and chloramphenicol residues in shrimps [J].
Dumont, V. ;
Huet, A. -C. ;
Traynor, I. ;
Elliott, C. ;
Delahaut, P. .
ANALYTICA CHIMICA ACTA, 2006, 567 (02) :179-183
[8]   Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Jonsson, Jan Ake .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :69-79
[9]   Determination of volatile phenols in red wines by dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry detection [J].
Farina, Laura ;
Boido, Eduardo ;
Carrau, Francisco ;
Dellacassa, Eduardo .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :46-50
[10]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640