Progressive thermal desorption of vapor mixtures from a preconcentrator with a porous metal foam internal architecture and variable thermal ramp rates

被引:12
作者
Grate, JW [1 ]
Anheier, NC [1 ]
Baldwin, DL [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
D O I
10.1021/ac049142s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A vapor preconcentrator has been designed with the porous polymer (renax) packed into a highly porous metal foam to facilitate thermal conductivity and temperature uniformity throughout the bed of the preconcentrator during heating. Vapors were desorbed using linear temperature programming from room temperature to a maximum temperature of 170 or 200 degrees C; the programmed duration of the thermal ramp was varied from 10 to 180 s. The partial separation of vapor mixtures that are thermally desorbed from the preconcentrator has been examined in terms of a metric for resolution, using methyl ethyl ketone, toluene, and dimethyl methylphosphonate as a test mixture. Vapors desorbed as a sequence of partially separated overlapping peaks, as observed with a polymer-coated flexural plate wave sensor. It was shown that vapor mixture resolution improved as the total time of the thermal ramp was extended from 30 to 120 s. In this way, the preconcentrator serves to act as a preseparator in addition to its usual functions for sampling, signal modulation, and improving sensitivity. Overlapping peaks were modeled, and peak areas were extracted using an exponentially modified Gaussian model. Peak areas were independent of the thermal ramp rate. Uses of such preconcentrators with multivariate detectors, such as sensor arrays, are discussed.
引用
收藏
页码:1867 / 1875
页数:9
相关论文
共 58 条
[1]  
[Anonymous], 1987, BINDING CONSTANTS ME
[2]   Development of a preconcentration unit for a SAW sensor micro array and its use for indoor air quality monitoring [J].
Bender, F ;
Barié, N ;
Romoudis, G ;
Voigt, A ;
Rapp, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3) :135-141
[3]   Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors [J].
Cai, QY ;
Park, J ;
Heldsinger, D ;
Hsieh, MD ;
Zellers, ET .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) :121-130
[4]   PERFORMANCE ADVANCES IN ION MOBILITY SPECTROMETRY THROUGH COMBINATION WITH HIGH-SPEED VAPOR SAMPLING, PRECONCENTRATION AND SEPARATION TECHNIQUES [J].
DWORZANSKI, JP ;
KIM, MG ;
SNYDER, AP ;
ARNOLD, NS ;
MEUZELAAR, HLC .
ANALYTICA CHIMICA ACTA, 1994, 293 (03) :219-235
[5]  
Feng CH, 2000, J MICROCOLUMN SEP, V12, P267, DOI 10.1002/(SICI)1520-667X(2000)12:4<267::AID-MCS11>3.0.CO
[6]  
2-B
[7]   Two-stage microtrap as an injection device for continuous on-line gas chromatographic monitoring [J].
Feng, CH ;
Mitra, S .
JOURNAL OF CHROMATOGRAPHY A, 1998, 805 (1-2) :169-176
[8]   Validation of alternating least-squares multivariate curve resolution for chromatographic resolution and quantitation [J].
Gargallo, R ;
Tauler, R ;
CuestaSanchez, F ;
Massart, DL .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) :279-286
[9]  
Giddings J.C., 1991, Unified separation science
[10]  
Grate JW, 2000, CHEM INNOV, V30, P29