Evaluation of volumetric blood collection devices for the measurement of phenylalanine and tyrosine to monitor patients with phenylketonuria

被引:24
|
作者
Carling, Rachel S. [1 ,2 ,5 ]
Emmett, Erin C. [2 ]
Moat, Stuart J. [3 ,4 ]
机构
[1] Kings Coll London, GKT Sch Med Educ, London, England
[2] Guys & St Thomas NHSFT, Biochem Sci, London, England
[3] Univ Hosp Wales, Dept Med Biochem Immunol & Toxicol, Cardiff, Wales
[4] Cardiff Univ, Univ Hosp Wales, Sch Med, Cardiff, Wales
[5] St Thomas Hosp, Biochem Sci, 4th Floor,North Wing,Westminster Bridge Rd, London SE1, England
关键词
Blood collection devices; Dried blood spots; DBS; Phenylalanine; Phenylketonuria; PKU; Microsampling; Tyrosine; Standardization; AMINO-ACIDS; HEMATOCRIT; PUNCH;
D O I
10.1016/j.cca.2022.08.005
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Measurement of dried blood spot (DBS) phenylalanine (Phe) is central to the monitoring of patients with phenylketonuria. However, the volume and hematocrit (Hct) of the blood applied to conventional DBS cards significantly affects analytical results. Volumetric blood collection devices are reported to be more accurate, precise and less prone to Hct effects.Methods: Accuracy, imprecision, effect of blood volume and Hct were evaluated for measurement of Phe and tyrosine using three volumetric devices and compared with the conventional PerkinElmer-226 filter-paper collection devices. i.e. conventional DBS cards. Applicability for use in a clinical laboratory was assessed qualitatively.Results: Blood volume did not impact on the performance of the volumetric devices; however, significant biases were observed with the conventional DBS card. A higher Hct introduced unacceptable bias for Neoteryx-Mitra and conventional DBS card. All devices had a mean relative standard deviation (RSD) <= 4.1 %, except for the Neoteryx-Mitra (<= 6.2 %). Relative to liquid blood, the mean biases of Phe for the various devices were-5.1 (HemaXis-DB10),-7.8 (Capitainer-qDBS),-12.0 (Neoteryx-Mitra) and-32.6 % (conventional DBS card).Conclusions: Introducing volumetric collection devices will overcome the significant pre-analytical issues asso-ciated with conventional DBS collection and improve the biochemical monitoring of patients with PKU.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 29 条
  • [21] Evaluating the Influence of Social Determinants of Health on Blood Phenylalanine Levels in Phenylketonuria Patients
    Afseth, Cassandra
    Knutsen, Josh
    Lamborn, Thomas
    Vucko, Erika
    Havens, Kirsten
    Shim, Soo
    Baker, Joshua
    AMERICAN JOURNAL OF MEDICAL GENETICS PART A, 2025, 197 (02)
  • [22] Simultaneous measurement of phenylalanine and tyrosine in phenylketonuric plasma and dried blood by high-performance liquid chromatography
    Dale, Y
    Mackey, V
    Mushi, R
    Nyanda, A
    Maleque, M
    Ike, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (01): : 1 - 8
  • [23] Sapropterin therapy increases stability of blood phenylalanine levels in patients with BH4-responsive phenylketonuria (PKU)
    Burton, Barbara K.
    Bausell, Heather
    Katz, Rachel
    LaDuca, Holly
    Sullivan, Christine
    MOLECULAR GENETICS AND METABOLISM, 2010, 101 (2-3) : 110 - 114
  • [24] RAPID DIAGNOSIS OF PHENYLKETONURIA BY QUANTITATIVE-ANALYSIS FOR PHENYLALANINE AND TYROSINE IN NEONATAL BLOOD SPOTS BY TANDEM MASS-SPECTROMETRY
    CHACE, DH
    MILLINGTON, DS
    TERADA, N
    KAHLER, SG
    ROE, CR
    HOFMAN, LF
    CLINICAL CHEMISTRY, 1993, 39 (01) : 66 - 71
  • [25] The evaluation of phenylalanine levels in Estonian phenylketonuria patients during eight years by electronic laboratory records
    Lillevali, Hardo
    Reinson, Karit
    Muru, Kai
    Saarsalu, Siret
    Kunnapas, Kadi
    Kahre, Tiina
    Murumets, Ulle
    Ounap, Katrin
    MOLECULAR GENETICS AND METABOLISM REPORTS, 2019, 19
  • [26] L-Phenylalanine concentration in blood of phenylketonuria patients: a modified enzyme colorimetric assay compared with amino acid analysis, tandem mass spectrometry, and HPLC methods
    De Silva, Veronica
    Oldham, Charlie D.
    May, Sheldon W.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (09) : 1271 - 1279
  • [27] Imatinib and norimatinib therapeutic monitoring using dried blood spots: Analytical and clinical validation, and performance comparison of volumetric collection devices
    Orleni, Marco
    Gagno, Sara
    Cecchin, Eleonora
    Montico, Marcella
    Buonadonna, Angela
    Fumagalli, Arianna
    Guardascione, Michela
    Puglisi, Fabio
    Toffoli, Giuseppe
    Posocco, Bianca
    Cecchin, Erika
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2025, 1255
  • [28] Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection
    Kip, A. E.
    Rosing, H.
    Hillebrand, M. J. X.
    Blesson, S.
    Mengesha, B.
    Diro, E.
    Hailu, A.
    Schellens, J. H. M.
    Beijnen, J. H.
    Dorlo, T. P. C.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2016, 60 (04) : 2081 - 2089
  • [29] A Novel LC-MS/MS Method for the Measurement of Elexacaftor, Tezacaftor and Ivacaftor in Plasma, Dried Plasma Spot (DPS) and Whole Blood in Volumetric Absorptive Microsampling (VAMS) Devices
    Pigliasco, Federica
    Cafaro, Alessia
    Barco, Sebastiano
    Cresta, Federico
    Casciaro, Rosaria
    Pedemonte, Nicoletta
    Mattioli, Francesca
    Castellani, Carlo
    Cangemi, Giuliana
    PHARMACEUTICS, 2025, 17 (02)