Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity

被引:14
作者
Yoon, Jeong Hee [1 ]
Lee, Jeong Min [1 ,2 ]
Lee, Eun Sun [3 ]
Baek, Jeehyun [4 ]
Lee, Sangwoo [5 ]
Iwadate, Yuji [6 ]
Han, Joon Koo [1 ,2 ]
Choi, Byung Ihn [1 ,2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul 110744, South Korea
[3] Natl Canc Ctr, Dept Radiol, Goyang Si, Gyeonggi Do, South Korea
[4] Human Med Imaging & Intervent Ctr, Seoul, South Korea
[5] GE Healthcare, Global Appl Sci Lab, Seoul, South Korea
[6] GE Healthcare, Global Appl Sci Lab, Tokyo, Japan
来源
ABDOMINAL IMAGING | 2015年 / 40卷 / 02期
关键词
Magnetic resonance imaging; Hepatobiliary phase; Respiratory-gated imaging; Gd-EOB-DTPA; Gadoxetic acid; HEPATOCELLULAR CARCINOMAS; OBSERVER PERFORMANCE; HEPATOBILIARY-PHASE; HEPATOCYTE PHASE; FLIP ANGLE; EOB-DTPA; 3.0; T; MRI; METASTASES; NODULES;
D O I
10.1007/s00261-014-0214-x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Purpose: To determine whether a navigator-gated three-dimensional T1-weighted gradient-echo sequence (T1W-GRE, navigated LAVA) can improve diagnostic performance for the detection of focal liver lesions (FLLs) compared to standard breath-hold (BH) T1W-GRE breath-hold LAVA (BH-LAVA) during the hepatobiliary phase (HBP) of gadoxetic acid liver magnetic resonance imaging (MRI) in patients with limited breath-holding capacity. Materials and methods: This retrospective study was approved by our institutional review board and the requirement for informed consent was waived. We included 372 patients who underwent liver MRI including both navigated LAVA and BH-LAVA sequences. Overall image quality of the two HBP image sets was compared. In patients with limited breath-holding capacity, diagnostic performances in detecting FLLs on the two HBP images were compared using jackknife-alternative free-response receiver-operating characteristic (JAFROC) analysis by two reviewers. Results: There were 13 cases (13/372; 3.5%) of image acquisition failure using the navigated LAVA sequence due to severe irregular breathing, and 50 of 359 patients had limited breath-holding capacity. In these patients, overall image quality of navigated LAVA (2.78 +/- 0.95) was significantly better than that of BH-LAVA (2.42 +/- 0.81, P < 0.005), and both readers showed significantly higher JAFROC figure-of-merit values with navigated LAVA compared to BH-LAVA (0.94 and 0.86 in reviewer 1, respectively; 0.89 and 0.83 in reviewer 2, respectively, P < 0.005). Overall image quality of navigated LAVA was also better than that of BH-LAVA in patients with sufficient breath-holding capacity (n = 309, 3.96 +/- 0.88, 3.81 +/- 0.66, respectively, P < 0.001). Conclusion: The navigated LAVA sequence could provide better image quality and diagnostic performance in detecting FLLs than BH-LAVA in patients with limited breath-holding capacity during HBP of gadoxetic acid MRI.
引用
收藏
页码:278 / 288
页数:11
相关论文
共 50 条
  • [41] Three-Tesla Imaging of the Pituitary and Parasellar Region: T1-Weighted 3-Dimensional Fast Spin Echo Cube Outperforms Conventional 2-Dimensional Magnetic Resonance Imaging
    Lien, Ruby J.
    Corcuera-Solano, Idoia
    Pawha, Puneet S.
    Naidich, Thomas P.
    Tanenbaum, Lawrence N.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (03) : 329 - 333
  • [42] Nature of the Intracellular-contrast-enhancing Fat-saturated T1-weighted Gradient-echo (ICE-TIGRE) Sequence: A Fat-suppressed T1-weighted Technique with Motion-sensitised Driven-equilibrium for Improved Contrast Enhancement in Liver Imaging
    Nishihara, Takashi
    Nakamura, Yuko
    Yoshizawa, Nobuyuki
    Takizawa, Masahiro
    Shirai, Toru
    Higaki, Toru
    Honda, Yukiko
    Awai, Kazuo
    Bito, Yoshitaka
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2025, 24 (01) : 133 - 143
  • [43] Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients
    Patrick B. Duffy
    Alto Stemmer
    Michael J. Callahan
    Joseph P. Cravero
    Patrick R. Johnston
    Simon K. Warfield
    Sarah D. Bixby
    Pediatric Radiology, 2021, 51 : 1645 - 1653
  • [44] Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients
    Duffy, Patrick B.
    Stemmer, Alto
    Callahan, Michael J.
    Cravero, Joseph P.
    Johnston, Patrick R.
    Warfield, Simon K.
    Bixby, Sarah D.
    PEDIATRIC RADIOLOGY, 2021, 51 (09) : 1645 - 1653
  • [45] Differentiating Liver Hemangioma from Metastatic Tumor Using T2-enhanced Spin-echo Imaging with a Time-reversed Gradient-echo Sequence in the Hepatobiliary Phase of Gadoxetic Acid-enhanced MR Imaging
    Takayama, Yukihisa
    Nishie, Akihiro
    Okamoto, Daisuke
    Fujita, Nobuhiro
    Asayama, Yoshiki
    Ushijima, Yasuhiro
    Yoshizumi, Tomoharu
    Yoneyama, Masami
    Ishigami, Kousei
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (03) : 445 - 457
  • [46] Three-Dimensional Black-Blood T1-Weighted Turbo Spin-Echo Techniques for the Diagnosis of Deep Vein Thrombosis in Comparison With Contrast-Enhanced Magnetic Resonance Imaging A Pilot Study
    Treitl, Karla Maria
    Treitl, Marcus
    Kooijman-Kurfuerst, Hendrik
    Kammer, Nora N.
    Coppenrath, Eva
    Suderland, Elena
    Czihal, Michael
    Hoffmann, Ulrich
    Reiser, Maximilian F.
    Saam, Tobias
    INVESTIGATIVE RADIOLOGY, 2015, 50 (06) : 401 - 408
  • [47] Automatic brain tissue extraction method using erosion-dilation treatment (BREED) from three-dimensional magnetic resonance imaging T1-weighted data
    Miura, N
    Taneda, A
    Shida, K
    Kawashima, R
    Kawazoe, Y
    Fukuda, H
    Shimizu, T
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) : 927 - 932
  • [48] Free-breathing dynamic T1WI using compressed sensing-golden angle radial sparse parallel imaging for liver MRI in patients with limited breath-holding capability
    Park, Jin Young
    Lee, Sang Min
    Lee, Jeong Sub
    Chang, Won
    Yoon, Jeong Hee
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 152
  • [49] To Compare Diagnostic Ability of Contrast-Enhanced Three-Dimensional T1-SPACE with Three-Dimensional Fluid-Attenuated Inversion Recovery and Three-Dimensional T1-Magnetization Prepared Rapid Gradient Echo Magnetic Resonance Sequences in Patients of Meningitis
    Kumar, Sudesh
    Kumar, Suresh
    Surya, Mukesh
    Mahajan, Anjali
    Sharma, Sanjiv
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2019, 10 (01) : 48 - 53
  • [50] Accuracy in local staging of prostate cancer by adding a three-dimensional T2-weighted sequence with radial reconstructions in magnetic resonance imaging
    Jaderling, Fredrik
    Nyberg, Tommy
    Oberg, Michael
    Carlsson, Stefan
    Skorpil, Mikael
    Blomqvist, Lennart
    ACTA RADIOLOGICA OPEN, 2018, 7 (02):