Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity

被引:14
作者
Yoon, Jeong Hee [1 ]
Lee, Jeong Min [1 ,2 ]
Lee, Eun Sun [3 ]
Baek, Jeehyun [4 ]
Lee, Sangwoo [5 ]
Iwadate, Yuji [6 ]
Han, Joon Koo [1 ,2 ]
Choi, Byung Ihn [1 ,2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul 110744, South Korea
[3] Natl Canc Ctr, Dept Radiol, Goyang Si, Gyeonggi Do, South Korea
[4] Human Med Imaging & Intervent Ctr, Seoul, South Korea
[5] GE Healthcare, Global Appl Sci Lab, Seoul, South Korea
[6] GE Healthcare, Global Appl Sci Lab, Tokyo, Japan
来源
ABDOMINAL IMAGING | 2015年 / 40卷 / 02期
关键词
Magnetic resonance imaging; Hepatobiliary phase; Respiratory-gated imaging; Gd-EOB-DTPA; Gadoxetic acid; HEPATOCELLULAR CARCINOMAS; OBSERVER PERFORMANCE; HEPATOBILIARY-PHASE; HEPATOCYTE PHASE; FLIP ANGLE; EOB-DTPA; 3.0; T; MRI; METASTASES; NODULES;
D O I
10.1007/s00261-014-0214-x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Purpose: To determine whether a navigator-gated three-dimensional T1-weighted gradient-echo sequence (T1W-GRE, navigated LAVA) can improve diagnostic performance for the detection of focal liver lesions (FLLs) compared to standard breath-hold (BH) T1W-GRE breath-hold LAVA (BH-LAVA) during the hepatobiliary phase (HBP) of gadoxetic acid liver magnetic resonance imaging (MRI) in patients with limited breath-holding capacity. Materials and methods: This retrospective study was approved by our institutional review board and the requirement for informed consent was waived. We included 372 patients who underwent liver MRI including both navigated LAVA and BH-LAVA sequences. Overall image quality of the two HBP image sets was compared. In patients with limited breath-holding capacity, diagnostic performances in detecting FLLs on the two HBP images were compared using jackknife-alternative free-response receiver-operating characteristic (JAFROC) analysis by two reviewers. Results: There were 13 cases (13/372; 3.5%) of image acquisition failure using the navigated LAVA sequence due to severe irregular breathing, and 50 of 359 patients had limited breath-holding capacity. In these patients, overall image quality of navigated LAVA (2.78 +/- 0.95) was significantly better than that of BH-LAVA (2.42 +/- 0.81, P < 0.005), and both readers showed significantly higher JAFROC figure-of-merit values with navigated LAVA compared to BH-LAVA (0.94 and 0.86 in reviewer 1, respectively; 0.89 and 0.83 in reviewer 2, respectively, P < 0.005). Overall image quality of navigated LAVA was also better than that of BH-LAVA in patients with sufficient breath-holding capacity (n = 309, 3.96 +/- 0.88, 3.81 +/- 0.66, respectively, P < 0.001). Conclusion: The navigated LAVA sequence could provide better image quality and diagnostic performance in detecting FLLs than BH-LAVA in patients with limited breath-holding capacity during HBP of gadoxetic acid MRI.
引用
收藏
页码:278 / 288
页数:11
相关论文
共 50 条
  • [31] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182
  • [32] Thin-slice Free-breathing Pseudo-golden-angle Radial Stack-of-stars with Gating and Tracking T1-weighted Acquisition: An Efficient Gadoxetic Acid-enhanced Hepatobiliary-phase Imaging Alternative for Patients with Unstable Breath Holding
    Kajita, Kimihiro
    Goshima, Satoshi
    Noda, Yoshifumi
    Kawada, Hiroshi
    Kawai, Nobuyuki
    Okuaki, Tomoyuki
    Honda, Masatoshi
    Matsuo, Masayuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (01) : 4 - 11
  • [33] Quantification of liver iron concentration with magnetic resonance imaging by combining T1-, T2-weighted spin echo sequences and a gradient echo sequence
    Kreeftenberg, HG
    Mooyaart, EL
    Huizenga, JR
    Sluiter, WJ
    Kreeftenberg, HG
    NETHERLANDS JOURNAL OF MEDICINE, 2000, 56 (04) : 133 - 137
  • [34] Automated histogram-based brain segmentation in T1-weighted three-dimensional magnetic resonance head images
    Shan, ZY
    Yue, GH
    Liu, JZ
    NEUROIMAGE, 2002, 17 (03) : 1587 - 1598
  • [35] Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
    Arai, Hideo
    Kawakubo, Masateru
    Abe, Ko
    Hatashima, Hikaru
    Sanui, Kenichi
    Nishimura, Hiroshi
    Kadokami, Toshiaki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (01) : 111 - 119
  • [36] Fat-suppressed, three-dimensional T1-weighted imaging using high-acceleration parallel acquisition and a dual-echo Dixon technique for gadoxetic acid-enhanced liver MRI at 3T
    Yoon, Jeong Hee
    Lee, Jeong Min
    Yu, Mi Hye
    Kim, Eun Ju
    Han, Joon Koo
    Choi, Byung Ihn
    ACTA RADIOLOGICA, 2015, 56 (12) : 1454 - 1462
  • [37] Three-dimensional susceptibility-weighted imaging and two-dimensional T2*-weighted gradient-echo imaging of intratumoral hemorrhages in pediatric diffuse intrinsic pontine glioma
    Loebel, Ulrike
    Sedlacik, Jan
    Sabin, Noah D.
    Kocak, Mehmet
    Broniscer, Alberto
    Hillenbrand, Claudia M.
    Patay, Zoltan
    NEURORADIOLOGY, 2010, 52 (12) : 1167 - 1177
  • [38] Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing
    Yoon, Jeong Hee
    Yu, Mi Hye
    Chang, Won
    Park, Jin-Young
    Nickel, Marcel Dominik
    Son, Yohan
    Kiefer, Berthold
    Lee, Jeong Min
    INVESTIGATIVE RADIOLOGY, 2017, 52 (10) : 596 - 604
  • [39] Validity of gradient-echo three-dimensional delayed gadolinium-enhanced magnetic resonance imaging of hip joint cartilage: A histologically controlled study
    Zilkens, Christoph
    Miese, Falk
    Herten, Monika
    Kurzidem, Sabine
    Jaeger, Marcus
    Koenig, Dietmar
    Antoch, Gerald
    Krauspe, Ruediger
    Bittersohl, Bernd
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : E81 - E86
  • [40] Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
    Hideo Arai
    Masateru Kawakubo
    Ko Abe
    Hikaru Hatashima
    Kenichi Sanui
    Hiroshi Nishimura
    Toshiaki Kadokami
    The International Journal of Cardiovascular Imaging, 2020, 36 : 111 - 119