Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity

被引:14
|
作者
Yoon, Jeong Hee [1 ]
Lee, Jeong Min [1 ,2 ]
Lee, Eun Sun [3 ]
Baek, Jeehyun [4 ]
Lee, Sangwoo [5 ]
Iwadate, Yuji [6 ]
Han, Joon Koo [1 ,2 ]
Choi, Byung Ihn [1 ,2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul 110744, South Korea
[3] Natl Canc Ctr, Dept Radiol, Goyang Si, Gyeonggi Do, South Korea
[4] Human Med Imaging & Intervent Ctr, Seoul, South Korea
[5] GE Healthcare, Global Appl Sci Lab, Seoul, South Korea
[6] GE Healthcare, Global Appl Sci Lab, Tokyo, Japan
来源
ABDOMINAL IMAGING | 2015年 / 40卷 / 02期
关键词
Magnetic resonance imaging; Hepatobiliary phase; Respiratory-gated imaging; Gd-EOB-DTPA; Gadoxetic acid; HEPATOCELLULAR CARCINOMAS; OBSERVER PERFORMANCE; HEPATOBILIARY-PHASE; HEPATOCYTE PHASE; FLIP ANGLE; EOB-DTPA; 3.0; T; MRI; METASTASES; NODULES;
D O I
10.1007/s00261-014-0214-x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Purpose: To determine whether a navigator-gated three-dimensional T1-weighted gradient-echo sequence (T1W-GRE, navigated LAVA) can improve diagnostic performance for the detection of focal liver lesions (FLLs) compared to standard breath-hold (BH) T1W-GRE breath-hold LAVA (BH-LAVA) during the hepatobiliary phase (HBP) of gadoxetic acid liver magnetic resonance imaging (MRI) in patients with limited breath-holding capacity. Materials and methods: This retrospective study was approved by our institutional review board and the requirement for informed consent was waived. We included 372 patients who underwent liver MRI including both navigated LAVA and BH-LAVA sequences. Overall image quality of the two HBP image sets was compared. In patients with limited breath-holding capacity, diagnostic performances in detecting FLLs on the two HBP images were compared using jackknife-alternative free-response receiver-operating characteristic (JAFROC) analysis by two reviewers. Results: There were 13 cases (13/372; 3.5%) of image acquisition failure using the navigated LAVA sequence due to severe irregular breathing, and 50 of 359 patients had limited breath-holding capacity. In these patients, overall image quality of navigated LAVA (2.78 +/- 0.95) was significantly better than that of BH-LAVA (2.42 +/- 0.81, P < 0.005), and both readers showed significantly higher JAFROC figure-of-merit values with navigated LAVA compared to BH-LAVA (0.94 and 0.86 in reviewer 1, respectively; 0.89 and 0.83 in reviewer 2, respectively, P < 0.005). Overall image quality of navigated LAVA was also better than that of BH-LAVA in patients with sufficient breath-holding capacity (n = 309, 3.96 +/- 0.88, 3.81 +/- 0.66, respectively, P < 0.001). Conclusion: The navigated LAVA sequence could provide better image quality and diagnostic performance in detecting FLLs than BH-LAVA in patients with limited breath-holding capacity during HBP of gadoxetic acid MRI.
引用
收藏
页码:278 / 288
页数:11
相关论文
共 50 条
  • [21] High incidence of microbleeds in hemodialysis patients detected by T2*-weighted gradient-echo magnetic resonance imaging
    Yokoyama, S
    Hirano, H
    Uomizu, K
    Kajiya, Y
    Tajitsu, K
    Kusumoto, K
    NEUROLOGIA MEDICO-CHIRURGICA, 2005, 45 (11) : 556 - 560
  • [22] Qualitative and Quantitative Analysis of a Spiral Gradient Echo Sequence for Contrast-Enhanced Fat-Suppressed T1-Weighted Spine Magnetic Resonance Imaging
    Sartoretti, Elisabeth
    Sartoretti, Thomas
    van Smoorenburg, Luuk
    Sartoretti-Schefer, Sabine
    Wyss, Michael
    Binkert, Christoph A.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (08) : 517 - 524
  • [23] Usefulness of breath-hold inversion recovery-prepared T1-weighted two-dimensional gradient echo sequence for detection of hepatocellular carcinoma in Gd-EOB-DTPA-enhanced MR imaging
    Ohno, Tsuyoshi
    Isoda, Hiroyoshi
    Furuta, Akihiro
    Arizono, Shigeki
    Yamashita, Rikiya
    Ono, Ayako
    Togashi, Kaori
    CLINICAL IMAGING, 2016, 40 (05) : 997 - 1003
  • [24] Osteochondral Lesions of the Talus Comparison of Three-Dimensional Fat-Suppressed Fast Spoiled Gradient-Echo Magnetic Resonance Imaging and Conventional Magnetic Resonance Imaging
    Hao, Da-Peng
    Zhang, Jian-Zhong
    Wang, Zhen-Chang
    Xu, Wen-Jian
    Liu, Ji-Hua
    Yang, Ben-Tao
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2010, 100 (03) : 189 - 194
  • [25] Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence
    Yoon, Min A.
    Hong, Suk-Joo
    Lee, Kyu-Chong
    Lee, Chang Hee
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (01) : 46 - 50
  • [26] Fat-Suppressed 3D T1-Weighted Gradient-Echo Imaging of the Cartilage With a Volumetric Interpolated Breath-Hold Examination
    Zheng, Zhuo-Zhao
    Shan, Han
    Li, Xuan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : W414 - W419
  • [27] Magnetic resonance imaging of focal fibrocartilaginous dysplasia - findings derived from a three-dimensional gradient echo sequence
    Lou, Luxin
    Li, Xinmin
    Gong, Lihua
    Zhang, Wei
    Zhou, Dafei
    Cheng, Xiaoguang
    Cheng, Kebin
    Yu, Aihong
    PEDIATRIC RADIOLOGY, 2022, 52 (01) : 58 - 64
  • [28] Clinical application of three-dimensional T1-weighted BrainVIEW in magnetic resonance imaging of cerebral venous thrombosis: a case report and literature review
    Yang, Cheng
    Fang, Huang
    Hu, Jun
    Li, Mei
    Wei, Chunxia
    Miao, Jinfei
    Huang, Wencai
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2023, 51 (04)
  • [29] Detection of Brain Metastases by 3-Dimensional Magnetic Resonance Imaging at 3 T: Comparison Between T1-Weighted Volume Isotropic Turbo Spin Echo Acquisition and 3-Dimensional T1-Weighted Fluid-Attenuated Inversion Recovery Imaging
    Yoshida, Atsushi
    Tha, Khin Khin
    Fujima, Noriyuki
    Zaitsu, Yuri
    Yoshida, Daisuke
    Tsukahara, Akiko
    Onodera, Shunsuke
    Shirato, Hiroki
    Terae, Satoshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 84 - 90
  • [30] Magnetic resonance imaging of focal fibrocartilaginous dysplasia — findings derived from a three-dimensional gradient echo sequence
    Luxin Lou
    Xinmin Li
    Lihua Gong
    Wei Zhang
    Dafei Zhou
    Xiaoguang Cheng
    Kebin Cheng
    Aihong Yu
    Pediatric Radiology, 2022, 52 : 58 - 64