AN EMBEDDED SYSTEM FOR AUTOMATED HYDROPONIC NUTRIENT SOLUTION MANAGEMENT

被引:26
作者
Cho, W. J. [1 ]
Kim, H. J. [1 ,2 ]
Jung, D. H. [1 ]
Kang, C. I. [3 ]
Choi, G. L. [4 ]
Son, J. E. [5 ]
机构
[1] Seoul Natl Univ, Dept Biosyst Engn & Biomat Sci, Seoul, South Korea
[2] Seoul Natl Univ, Res Inst Agr & Life Sci, Seoul, South Korea
[3] Scientec Lab Ctr Co Ltd, Daejeon, South Korea
[4] Natl Inst Hort Herbal Sci, Protected Hort Res Stn, Gyeongsangnam Do, South Korea
[5] Seoul Natl Univ, Dept Plant Sci, Seoul, South Korea
关键词
Automatic control; Closed system; Dosing algorithm; Embedded system; Greenhouse; Ion sensor; Nutrients; ION-SELECTIVE ELECTRODES; COMPUTER-CONTROLLED SYSTEM; GREENHOUSE CULTIVATION; SENSORS; TONGUE; ARRAY;
D O I
10.13031/trans.12163
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
An ideal closed hydroponic system would include automated preparation of nutrient solutions, including reuse of the drain solution with replenishment of fertilizers and water in proper ratios based on real-time measurement of various nutrient concentrations in the drain solution. The electrical conductivity (EC) based systems commonly used for managing hydroponic nutrients in closed systems do not allow individual corrections to each nutrient deficient for crop growth. To improve the performance of a PC-based nutrient management system originally developed in our previous study, this article describes the development and evaluation of a WinCE-based embedded system with robustness and an easy-to-use user interface, consisting mainly of a micro-control unit (MCU) based embedded nutrient controller and an array of ion-selective electrodes (ISEs) that can automatically control the nutrient replenishment events based on real-time measurements of NO3, K, and Ca concentrations. To overcome the problem of decoupled replenishment among the three nutrients found in the previous study, a robust fertilizer dosing algorithm was designed that can separately calculate the volumes of six nutrient stock solutions to be supplied in a sequential order according to specific ions. In a five-step spiking test, the use of a two-point normalization method prior to each measurement sequence coupled with the robust nutrient dosing algorithm enabled the system to formulate five different concentrations of NO3 and K ions comparable to the target concentrations. However, the five different Ca concentrations prepared were almost 33% higher than the target concentrations because of low Ca estimates due to a change in the sensitivity of the Ca ISE between the different background solutions used for calibration and measurement. This could be overcome with the use of the same background solution or a pre-sensitivity compensation when an initial measurement is made. In a lettuce cultivation test conducted with the ebb-and-flow method over 27 days, the nutrient control performance of the embedded system was improved as compared to the previously developed PC-based system while maintaining the target concentrations of 436, 117, and 80 mg L-1 within errors of -15.0 +/- 18.1, -5.0 +/- 10.0, and -9.2 +/- 4.1 mg L-1 for NO3, K, and Ca ions, respectively. The use of the developed system in closed crop cultivation proved to be feasible for managing individual nutrients in reused solution at desired concentration levels, resulting in the potential of maximizing the efficiency of nutrient use.
引用
收藏
页码:1083 / 1096
页数:14
相关论文
共 19 条
[1]   MONITORING NUTRIENT FILM SOLUTIONS USING ION-SELECTIVE ELECTRODES [J].
BAILEY, BJ ;
HAGGETT, BGD ;
HUNTER, A ;
ALBERY, WJ ;
SVANBERG, LR .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1988, 40 (02) :129-142
[2]   Ion-Specific Nutrient Management in Closed Systems: The Necessity for Ion-Selective Sensors in Terrestrial and Space-Based Agriculture and Water Management Systems [J].
Bamsey, Matthew ;
Graham, Thomas ;
Thompson, Cody ;
Berinstain, Alain ;
Scott, Alan ;
Dixon, Michael .
SENSORS, 2012, 12 (10) :13349-13392
[3]  
Choi G. L., 2015, KOREAN J HORT SCI S1, V33, P82
[4]  
Cloutier G. R., 1997, P 6 EUR S SPAC ENV C, P851
[5]   Automated system developed to control pH and concentration of nutrient solution evaluated in hydroponic lettuce production [J].
Domingues, Diego S. ;
Takahashi, Hideaki W. ;
Camara, Carlos A. P. ;
Nixdorf, Suzana L. .
COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2012, 84 :53-61
[6]   Computer-controlled system for ISEs automatic calibration [J].
Dorneanu, SA ;
Coman, V ;
Popescu, IC ;
Fabry, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (02) :521-531
[7]   ISE and chemfet sensors in greenhouse cultivation [J].
Gieling, TH ;
van Straten, G ;
Janssen, HJJ ;
Wouters, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (01) :74-80
[8]   Application of a potentiometric electronic tongue to fertigation strategy in greenhouse cultivation [J].
Gutierrez, M. ;
Alegret, S. ;
Caceres, R. ;
Casadesus, J. ;
Marfa, O. ;
del Valle, M. .
COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2007, 57 (01) :12-22
[9]   Nutrient solution monitoring in greenhouse cultivation employing a potentiometric electronic tongue [J].
Gutierrez, Manuel ;
Alegret, Salvador ;
Caceres, Rafaela ;
Casadesus, Jaume ;
Marfa, Oriol ;
del Valle, Manuel .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (06) :1810-1817
[10]   Using a low-cost SoC computer and a commercial RTOS in an embedded systems design course [J].
Hamblen, James O. .
IEEE TRANSACTIONS ON EDUCATION, 2008, 51 (03) :356-363