An Iterative Framework for Improving the Accuracy of Intraoperative Intensity-Based 2D/3D Registration for Image-Guided Orthopedic Surgery

被引:0
作者
Otake, Yoshito [1 ]
Armand, Mehran [2 ]
Sadowsky, Ofri [1 ]
Armiger, Robert S. [2 ]
Kazanzides, Peter [1 ]
Taylor, Russell H. [1 ]
机构
[1] Johns Hopkins Univ, Dept Comp Sci, 3400 N Charles St, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Appl Phys Lab, Johns Hopkins Rd, Laurel, MD 20723 USA
来源
INFORMATION PROCESSING IN COMPUTER-ASSISTED INTERVENTIONS | 2010年 / 6135卷
关键词
Intensity-based 2D/3D registration; Image-guided therapy; X-RAY; CT; RECONSTRUCTION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We propose an iterative refinement framework that improves the accuracy of intraoperative intensity-based 2D/3D registration. The method optimizes both the extrinsic camera parameters and the object pose. The algorithm estimates the transformation between the fiducials and the patient intraoperatively using a small number of X-ray images. The proposed algorithm was validated in an experiment using a cadaveric phantom, in which the true registration was acquired from CT data. The results of 50 registration trials with randomized initial conditions on a pair of X-ray C-arm images taken at 32 degrees angular separation showed that the iterative refinement process improved the translational error by 0.32 mm and the rotational error by 0.61 degrees when compared to the 2D/3D registration without iteration. This tool has the potential to allow routine use of image guided therapy by computing registration parameters using only two X-ray images.
引用
收藏
页码:23 / +
页数:2
相关论文
共 14 条
[1]   Automatic 3D-to-2D registration for CT and dual-energy digital radiography for calcification detection [J].
Chen, Xiang ;
Gilkeson, Robert C. ;
Fei, Baowei .
MEDICAL PHYSICS, 2007, 34 (12) :4934-4943
[2]   On averaging rotations [J].
Gramkow, C .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2001, 42 (1-2) :7-16
[3]   Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot [J].
Guéziec, A ;
Kazanzides, P ;
Williamson, B ;
Taylor, RH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :715-728
[4]   CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING UNIT QUATERNIONS [J].
HORN, BKP .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (04) :629-642
[5]  
Jain A, 2006, LECT NOTES COMPUT SC, V4190, P494
[6]   Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT [J].
Livyatan, H ;
Yaniv, Z ;
Joskowicz, L .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) :1395-1406
[7]   Distribution of Fiducial Registration Error in Rigid-Body Point-Based Registration [J].
Moghari, Mehdi Hedjazi ;
Abolmaesumi, Purang .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) :1791-1801
[8]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[9]   Image registration by maximization of combined mutual information and gradient information [J].
Pluim, JPW ;
Maintz, JBA ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (08) :809-814
[10]   Projected tetrahedra revisited: A barycentric formulation applied to digital radiograph reconstruction using higher-order attenuation functions [J].
Sadowsky, O ;
Cohen, JD ;
Taylor, RH .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2006, 12 (04) :461-473