Investigating the effect of flow compensation and quantitative susceptibility mapping method on the accuracy of venous susceptibility measurement

被引:16
作者
Berg, Ronja C. [1 ]
Preibisch, Christine [1 ,2 ,3 ]
Thomas, David L. [4 ,5 ,6 ]
Shmueli, Karin [7 ]
Biondetti, Emma [7 ,8 ,9 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Neuroradiol, Klinikum Rechts Isar, Munich, Germany
[2] Tech Univ Munich, Sch Med, TUM Neuroimaging Ctr, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[3] Tech Univ Munich, Sch Med, Neurol Clin, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[4] UCL, UCL Queen Sq Inst Neurol, Dept Brain Repair & Rehabil, London WC1N 3AR, England
[5] UCL, UCL Queen Sq Inst Neurol, Dementia Res Ctr, London WC1N 3AR, England
[6] UCL, UCL Queen Sq Inst Neurol, Wellcome Ctr Human Neuroimaging, London WC1N 3AR, England
[7] UCL, Dept Med Phys & Biomed Engn, London WC1E 6BT, England
[8] Sorbonne Univ, Team Movement Invest & Therapeut MOVIT, Inst Cerveau ICM Ctr Neuro Imagerie Rech, CENIR,INSERM U 1127,CNRS UMR 7225, Paris, France
[9] DAnnunzio Univ Chieti Pescara, Dept Neurosci Imaging & Clin Sci, Inst Adv Biomed Technol, I-66100 Chieti, Italy
基金
英国工程与自然科学研究理事会; 英国惠康基金; 欧洲研究理事会;
关键词
Quantitative susceptibility mapping; Venous oxygenation; Flow compensation; Vein segmentation; Sequence design; Image processing; OXYGEN EXTRACTION FRACTION; CEREBRAL-BLOOD-FLOW; MAGNETIC-SUSCEPTIBILITY; SPATIAL VARIATION; RECONSTRUCTION; REGULARIZATION; SEGMENTATION; VALIDATION; METABOLISM; IMAGE;
D O I
10.1016/j.neuroimage.2021.118399
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Quantitative susceptibility mapping (QSM) is a promising non-invasive method for obtaining information relating to oxygen metabolism. However, the optimal acquisition sequence and QSM reconstruction method for reliable venous susceptibility measurements are unknown. Full flow compensation is generally recommended to correct for the influence of venous blood flow, although the effect of flow compensation on the accuracy of venous susceptibility values has not been systematically evaluated. In this study, we investigated the effect of different acquisition sequences, including different flow compensation schemes, and different QSM reconstruction methods on venous susceptibilities. Ten healthy subjects were scanned with five or six distinct QSM sequence designs using monopolar readout gradients and different flow compensation schemes. All data sets were processed using six different QSM pipelines and venous blood susceptibility was evaluated in whole-brain segmentations of the venous vasculature and single veins. The quality of vein segmentations and the accuracy of venous susceptibility values were analyzed and compared between all combinations of sequences and reconstruction methods. The influence of the QSM reconstruction method on average venous susceptibility values was found to be 2.7- 11.6 times greater than the influence of the acquisition sequence, including flow compensation. The majority of the investigated QSM reconstruction methods tended to underestimate venous susceptibility values in the vein segmentations that were obtained. In summary, we found that multi-echo gradient-echo acquisition sequences without full flow compensation yielded venous susceptibility values comparable to sequences with full flow compensation. However, the QSM reconstruction method had a great influence on susceptibility values and thus needs to be selected carefully for accurate venous QSM.
引用
收藏
页数:13
相关论文
共 62 条
[1]   Comparison of MRI methods for measuring whole-brain venous oxygen saturation [J].
Barhoum, Suliman ;
Rodgers, Zachary B. ;
Langham, Michael ;
Magland, Jeremy F. ;
Li, Cheng ;
Wehrli, Felix W. .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) :2122-2128
[2]  
Bazin P.-L., 2015, P 24 ANN M ISMRM TOR
[3]   3T non-injected phase-contrast MRI sequences for the mapping of the external carotid branches: In vivo radio-anatomical pilot study for feasibility analysis [J].
Bettoni, Jeremie ;
Page, Gwenael ;
Salsac, Anne-Virginie ;
Constans, Jean-Marc ;
Testelin, Sylvie ;
Devauchelle, Bernard ;
Baledent, Olivier ;
Dakpe, Stephanie .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (01) :98-106
[4]  
Bilgic B., 2020, QSM RECONSTRUCTION C, DOI [10.1101/2020.11.25.397695, DOI 10.1101/2020.11.25.397695]
[5]  
Biondetti E., 2016, P 24 INT SOC MAGN RE
[6]   Investigating the accuracy and precision of TE-dependent versus multi-echo QSM using Laplacian-based methods at 3 T [J].
Biondetti, Emma ;
Karsa, Anita ;
Thomas, David L. ;
Shmueli, Karin .
MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) :3040-3053
[7]   Investigating the oxygenation of brain arteriovenous malformations using quantitative susceptibility mapping [J].
Biondetti, Emma ;
Rojas-Villabona, Alvaro ;
Sokolska, Magdalena ;
Pizzini, Francesca B. ;
Jager, Hans Rolf ;
Thomas, David L. ;
Shmueli, Karin .
NEUROIMAGE, 2019, 199 :440-453
[8]  
Brown R.W., 2014, Magnetic Resonance Imaging: Physical Principles and Sequence Design
[9]   Measurements of venous oxygen saturation in the superior sagittal sinus using conventional 3D multiple gradient-echo MRI: Effects of flow velocity and acceleration [J].
Cheng, Chou-Ming ;
Chou, Chih-Che ;
Yeh, Tzu-Chen ;
Chung, Hsiao-Wen .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (02) :995-1003
[10]   Cerebral oxygen extraction fraction (OEF): Comparison of challenge-free gradient echo QSM plus qBOLD (QQ) with 15O PET in healthy adults [J].
Cho, Junghun ;
Lee, John ;
An, Hongyu ;
Goyal, Manu S. ;
Su, Yi ;
Wang, Yi .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2021, 41 (07) :1658-1668