A decade of short-term outcomes in post-cardiac surgery ventricular assist device implantation - Data from the Society of Thoracic Surgeons' National Cardiac Database

被引:80
作者
Hernandez, Adrian F.
Grab, Joshua D.
Gammie, James S.
O'Brien, Sean M.
Hammill, Bradley G.
Rogers, Joseph G.
Camacho, Margarita T.
Dullum, Mercedes K.
Ferguson, Bruce
Peterson, Eric D.
机构
[1] Duke Univ, Clin Res Inst, Durham, NC 27715 USA
[2] Univ Maryland, Med Ctr, Baltimore, MD 21201 USA
[3] Newark Beth Israel Med Ctr, Newark, NJ 07112 USA
[4] Cleveland Clin Florida, Ft Lauderdale, FL USA
[5] Eastern Carolina Univ, Brody Sch Med, Greenville, NC USA
关键词
cardiopulmonary bypass; heart-assist device; shock; surgery;
D O I
10.1161/CIRCULATIONAHA.106.666289
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Previous studies showed 75% mortality before hospital discharge in patients with a ventricular assist device (VAD) placed for post-cardiac surgery shock. We examined a large national clinical database to assess trends in the incidence of post - cardiac surgery shock requiring VAD implantation, survival rates, and risk factors for mortality. Methods and Results - We identified patients undergoing a VAD procedure after cardiac surgery at US hospitals participating in the Society of Thoracic Surgeons' National Cardiac Database during the years 1995 to 2004. Baseline characteristics and operative outcomes were analyzed in 2.5-year increments. Logistic regression modeling was performed to provide risk- adjusted operative mortality and morbidity odds ratios. A total of 5735 patients had a VAD placed during the 10-year period (0.3% cardiac surgeries). Overall survival rate to discharge after VAD placement was 54.1%. With the earliest period (January 1995 through June 1997) used as reference, the mortality odds ratio declined to 0.72 ( July 1997 through December 1999) and eventually to 0.41 (July 2002 through December 2004; P < 0.0001). The combined mortality/ morbidity odds ratio also declined, to 0.84 and 0.48 over identical periods (P < 0.0001). Preoperative characteristics associated with increased mortality were urgency of procedure, reoperation, renal failure, myocardial infarction, aortic stenosis, female sex, race, peripheral vascular disease, New York Heart Association class IV, cardiogenic shock, left main coronary stenosis, and valve procedure (c index = 0.755). Conclusions - After adjustment for clinical characteristics of patients requiring mechanical circulatory support, rates of survival to hospital discharge have improved dramatically. Insertion of a VAD for post-cardiac surgery shock is an important therapeutic intervention that can salvage most of these patients.
引用
收藏
页码:606 / 612
页数:7
相关论文
共 16 条
[1]   The logistics and cost-effectiveness of circulatory support: Advantages of the ABIOMED BVS 5000 [J].
Couper, GS ;
Dekkers, RJ ;
Adams, DH .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :646-649
[2]   Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: Third Annual Report - 2005 [J].
Deng, MC ;
Edwards, LB ;
Hertz, MI ;
Rowe, AW ;
Keck, BM ;
Kormos, R ;
Naftel, DC ;
Kirklin, JK ;
Taylor, DO .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (09) :1182-1187
[3]   Improved results for postcardiotomy cardiogenic shock with the use of implantable left ventricular assist devices [J].
DeRose, JJ ;
Umana, JP ;
Argenziano, M ;
Catanese, KA ;
Levin, HR ;
Sun, BC ;
Rose, EA ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 1997, 64 (06) :1757-1762
[4]   Use of continuous quality improvement to increase use of process measures in patients undergoing coronary artery bypass graft surgery - A randomized controlled trial [J].
Ferguson, TB ;
Peterson, ED ;
Coombs, LP ;
Eiken, MC ;
Carey, ML ;
Grover, FL ;
DeLong, ER .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (01) :49-56
[5]   A decade of change - Risk profiles and outcomes for isolated coronary artery bypass grafting procedures, 1990-1999: A report from the STS National Database Committee and the Duke Clinical Research Institute [J].
Ferguson, TB ;
Hammill, BG ;
Peterson, ED ;
DeLong, ER ;
Grover, FL .
ANNALS OF THORACIC SURGERY, 2002, 73 (02) :480-489
[6]   POSTCARDIOTOMY SHOCK - CLINICAL-EVALUATION OF THE BVS-5000 BIVENTRICULAR SUPPORT SYSTEM [J].
GUYTON, RA ;
SCHONBERGER, JPAM ;
EVERTS, PAM ;
JETT, GK ;
GRAY, LA ;
GIELCHINSKY, I ;
RAESS, DH ;
VLAHAKES, GJ ;
WOOLLEY, SR ;
GANGAHAR, DM ;
SOLTANZADEH, H ;
PICCIONE, WJ ;
VAUGHN, CC ;
BOONSTRA, PW ;
BUCKLEY, MJ .
ANNALS OF THORACIC SURGERY, 1993, 56 (02) :346-356
[7]   Prognosis after the implantation of an intra-aortic balloon pump in cardiac surgery calculated with a new score [J].
Hausmann, H ;
Potapov, EV ;
Koster, A ;
Krabatsch, T ;
Stein, J ;
Yeter, R ;
Kukucka, M ;
Sodian, R ;
Kuppe, H ;
Hetzer, R .
CIRCULATION, 2002, 106 (13) :I203-I206
[8]   Left ventricular assist device bridge-to-transplant network improves survival after failed cardiotomy [J].
Helman, DN ;
Morales, DLS ;
Edwards, NM ;
Mancini, DM ;
Chen, JM ;
Rose, EA ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 1999, 68 (04) :1187-1194
[9]   ABIOMED BVS 5000: Experience and potential advantages [J].
Jett, GK .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :301-304
[10]   Initial experience with miniature axial flow ventricular assist devices for postcardiotomy heart failure [J].
Jurmann, MJ ;
Siniawski, H ;
Erb, M ;
Drews, T ;
Hetzer, R .
ANNALS OF THORACIC SURGERY, 2004, 77 (05) :1642-1647