The impact of edema on planning 125I and 103Pd prostate implants

被引:53
|
作者
Yue, N
Dicker, AP
Nath, R
Waterman, FM
机构
[1] Yale Univ, Sch Med, Dept Therapeut Radiol, New Haven, CT 06510 USA
[2] Thomas Jefferson Univ, Jefferson Med Coll, Dept Radiat Oncol, Philadelphia, PA 19107 USA
关键词
brachytherapy; prostate implants; I-125; Pd-103; edema; dose evaluation; preimplant planning;
D O I
10.1118/1.598585
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Permanent transperineal interstitial I-125 and Pd-103 prostate implants are generally planned to deliver a specific dose to a clinically defined target volume; however, the post-implant evaluation usually reveals that the implant delivered a lower or higher dose than planned. This difference is generally attributed to such factors as source placement errors, overestimation of the prostate volume on CT, and post-implant edema. In the present work we investigate the impact of edema alone. In routine prostate implant planning, it is customary to assume that both the prostate and seeds are static throughout the entire treatment time, and post-implant edema is not taken into consideration in the dosimetry calculation. However, prostate becomes edematous after seed implantation, typically by 50% in volume [Int. J. Radiat. Oncol., Biol., Phys. 41, 1069-1077 (1998)]. The edema resolves itself exponentially with a typical half-life of 10 days. In this work, the impact of the edema-induced dynamic change in prostate volume and seed location on the dose coverage of the prostate is investigated. The total dose delivered to the prostate was calculated by use of a dynamic model, which takes edema into account. In the model, the edema resolves exponentially with time, as reported in a separate study based on serial CT scans [Int. J. Radiat. Oncol., Biol., Phys. 41, 1069-1077 (1998)]. The model assumes that the seeds were implanted exactly as planned, thus eliminating the effect of source placement errors. Implants based on the same transrectal ultrasound (TRUS) images were planned using both I-125 and Pd-103 sources separately. The preimplant volume and planned seed locations were expanded to different degrees of edema to simulate the postimplant edematous prostate on day 0. The model calculated the dose in increments of 24 h, appropriately adjusting the prostate volume, seed locations, and source strength prior to each time interval and compiled dose-volume histograms (DVH) of the total dose delivered. A total of 30 such DVHs were generated for each implant using different combinations of edema half-life and magnitude. In addition, a DVH of the plan was compiled in the conventional manner, assuming that the prostate volume and seeds were static during treatment. A comparison of the DVH of the static model to the 30 edema corrected DVHs revealed that the plan overestimated the total dose by an amount that increased with the magnitude of the edema and the edema half-life. The maximum overestimation was 15% for I-125 and 32% for (103)pd. For more typical edema parameters (a 50% increase in volume and a 10 day half-life) the static plan for I-125 overestimated the total dose by about 5%, whereas that for Pd-103 overestimated it by about 12%. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00705-1].
引用
收藏
页码:763 / 767
页数:5
相关论文
共 50 条
  • [41] Verification of air-kerma strength of 125I seed for permanent prostate implants in Japan
    Iori Sumida
    Masahiko Koizumi
    Yutaka Takahashi
    Toshiyuki Ogata
    Yuichi Akino
    Fumiaki Isohashi
    Koji Konishi
    Yasuo Yoshioka
    Takehiro Inoue
    International Journal of Clinical Oncology, 2009, 14 : 525 - 528
  • [42] On the use of apparent activity (Aapp) for treatment planning of 125I and 103Pd interstitial brachytherapy sources:: Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Subcommittee on Low-Energy Brachytherapy Source Dosimetry
    Williamson, JF
    Coursey, BM
    DeWerd, LA
    Hanson, WF
    Nath, R
    Rivard, RJ
    Ibbott, G
    MEDICAL PHYSICS, 1999, 26 (12) : 2529 - 2530
  • [43] The effect of voxel size on the accuracy of dose-volume histograms of prostate 125I seed implants
    Corbett, JF
    Jezioranski, J
    Crook, J
    Yeung, I
    MEDICAL PHYSICS, 2002, 29 (06) : 1003 - 1006
  • [44] Urinary morbidity after 125I brachytherapy of the prostate
    Mallick, S
    Azzouzi, R
    Cormier, L
    Peiffert, D
    Mangin, P
    BJU INTERNATIONAL, 2003, 92 (06) : 555 - 558
  • [45] 125I brachytherapy in younger prostate cancer patients
    Kindts, Isabelle
    Stellamans, Karin
    Billiet, Ignace
    Pottel, Hans
    Lambrecht, Antoon
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 (09) : 707 - 713
  • [46] Dosimetric impact of contouring and image registration variability on dynamic 125I prostate brachytherapy
    Westendorp, Hendrik
    Kathrin, Surmann
    van de Pol, Sandrine M. G.
    Hoekstra, Carel J.
    Kattevilder, Robert A. J.
    Nuver, Tonnis T.
    Moerland, Marinus A.
    Slump, Cornelis H.
    Minken, Andre W.
    BRACHYTHERAPY, 2017, 16 (03) : 572 - 578
  • [47] Dosimetric characteristics of the new RadioCoil™ 103Pd wire line source for use in permanent brachytherapy implants
    Meigooni, AS
    Zhang, H
    Clark, JR
    Rachabatthula, V
    Koona, RA
    MEDICAL PHYSICS, 2004, 31 (11) : 3095 - 3105
  • [48] The role of external beam radiotherapy with I-125/Pd-103 brachytherapy for prostate carcinoma
    Blasko, JC
    Grimm, PD
    Sylsvester, JE
    Cavanagh, W
    RADIOTHERAPY AND ONCOLOGY, 2000, 57 (03) : 273 - 278
  • [49] There is a wide range of predictive dosimetric factors for I-125 and Pd-103 prostate brachytherapy
    Herstein, Andrew
    Wallner, Kent
    Merrick, Gregory
    Orio, Peter
    Thornton, Ken
    Butler, Wayne
    Sutlief, Steven
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2008, 31 (01): : 6 - 10
  • [50] Single-nucleotide polymorphisms studied for associations with urinary toxicity from 125I prostate brachytherapy implants
    Usmani, Nawaid
    Leong, Nelson
    Martell, Kevin
    Lan, Lanna
    Ghosh, Sunita
    Pervez, Nadeem
    Pedersen, John
    Yee, Don
    Murtha, Albert
    Amanie, John
    Sloboda, Ron
    Murray, David
    Parliament, Matthew
    BRACHYTHERAPY, 2014, 13 (03) : 285 - 291