Peripheral dose from a linear accelerator equipped with multileaf collimation

被引:55
作者
Stern, RL [1 ]
机构
[1] Univ Calif Davis, Davis Canc Ctr, Dept Radiat Oncol, Sacramento, CA 95817 USA
关键词
peripheral dose; multileaf collimator; radiation dosimetry;
D O I
10.1118/1.598557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In radiation therapy, knowledge of the peripheral dose is important when anatomical structures with very low dose tolerances might be involved. Two of the major sources of peripheral dose, leakage from the linac head, and scatter from secondary collimators, depend strongly on the configuration of the Linac head and therefore might be affected by the presence of a multileaf collimator (MLC). In this study, peripheral dose was measured at two depths and two held sizes for 6 and 18 MV photons from a linac with a MLC. The MLC was configured both with leaves fully retracted and with leaves positioned at the field edges defined by the secondary collimator jaws. Comparative measurements were also made for 6 MV photons from a linac without MLC. Peripheral dose was determined as a percentage of the central axis dose for the same energy, field size, and depth using diode detectors in solid phantom material. The data for the 6 MV without MLC agreed with those for the beam with MLC leaves retracted. For both energies at all depths and distances from the held edge, configuring the MLC leaves at the field edge yielded a reduction in peripheral dose of 6%-50% compared to MLC leaves fully retracted. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)01504-7].
引用
收藏
页码:559 / 563
页数:5
相关论文
共 19 条
[11]   RADIATION-RELATED SMALL HEAD SIZES AMONG PRENATALLY EXPOSED A-BOMB SURVIVORS [J].
OTAKE, M ;
SCHULL, WJ .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1993, 63 (02) :255-270
[12]  
ROUX C, 1983, HEALTH PHYS, V45, P993
[13]  
Sanchez-Reyes A, 1994, Med Dosim, V19, P83
[14]  
SCHULL WJ, 1991, ANN ICRP
[15]   MEASUREMENT AND CALCULATION OF OVARY AND FETUS DOSE IN EXTENDED FIELD RADIOTHERAPY FOR 10 MV X-RAYS [J].
SHARMA, SC ;
WILLIAMSON, JF ;
KHAN, FM ;
LEE, CKK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (06) :843-846
[16]   MEASUREMENTS OF DOSE FROM SECONDARY RADIATION OUTSIDE A TREATMENT FIELD - EFFECTS OF WEDGES AND BLOCKS [J].
SHERAZI, S ;
KASE, KR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (12) :2171-2176
[17]   FETAL DOSE FROM RADIOTHERAPY WITH PHOTON BEAMS - REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-36 (VOL 22, PG 63, 1995) [J].
STOVALL, M ;
BLACKWELL, CR ;
CUNDIFF, J ;
NOVACK, DH ;
PALTA, JR ;
WAGNER, LK ;
WEBSTER, EW ;
SHALEK, RJ .
MEDICAL PHYSICS, 1995, 22 (08) :1353-1354
[18]  
STOVALL M, 1995, MED PHYS, V22, P62
[19]   CALCULATION AND MEASUREMENT OF THE DOSE AT POINTS OUTSIDE THE PRIMARY BEAM FOR PHOTON ENERGIES OF 6-MV, 10-MV, AND 23-MV [J].
VANDERGIESSEN, PH .