On Conditioning of Resistive Strain Gage Channel Connected in Quarter Bridge Configuration in Measurement of Moderately Large Strains

被引:0
|
作者
Ziolkowski, A. [1 ]
Luckner, J. [1 ]
Dietrich, L. [1 ]
机构
[1] Polish Acad Sci, Inst Fundamental Technol Res, Warsaw, Poland
关键词
Experimental Data Acquisition; Data Processing; Nonlinear Transfer Functions; Nonlinear Signal Conditioning; Experimental Strain/Stress Analysis; Accurate Finite Strain Measurements; Resistance Strain Gages; Nonlinear Sensors; Small/Technical Strain; Logarithmic/Natural Strain; Moderate Strains; Quarter Bridge Configuration; Wheatstone Bridge Circuits; Shunt Calibration; Scaling Amplifier Gain; INVARIANCE;
D O I
10.1007/s40799-016-0070-4
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In response to engineering needs of measuring moderate or large strains in metallic structures' progress in resistance strain gages, technology resulted in widening the measurement range of this type of sensors to a range of 10-15%. For precision strain measurement applications, especially when a considerable number of measurement points are involved, single strain gage sensors are commonly used in quarter Wheatstone bridge configurations. Extension of measurement range to moderate strains requires taking into account inherent nonlinearities in signal transfer functions of the elements present in measurement chain. This work discusses in detail the most important ones, that is resistive gage sensor and quarter bridge measurement configuration nonlinearities to indicate that they are of the same order for moderate strains. Quite straightforward, shunt calibration procedure, taking into account these nonlinearities, is delivered or proposed enabling elimination of systematic errors. Thus, optimum accuracy of strain measurements matching the characteristics of components of strain measurement system can be conveniently achieved upon following simple steps. Inverse hyperbolic tangent-epsilon(Ln) = tanh(-1)(2.e(0)/E-ex)-linking scalar logarithmic strain and bridge reduced output voltage is shown to be a transfer function of strain measurement system with gage sensor in quarter bridge configuration for moderate or large strains.
引用
收藏
页码:689 / 704
页数:16
相关论文
共 3 条
  • [1] On Conditioning of Resistive Strain Gage Channel Connected in Quarter Bridge Configuration in Measurement of Moderately Large Strains
    A. Ziółkowski
    J. Luckner
    L. Dietrich
    Experimental Techniques, 2016, 40 : 689 - 704
  • [2] Strain Measurement Method Based on External Symmetrical Compensation Bridge Composed of Strain Gauges with Four-Wire Configuration for a Large-Scale NbTi Superconducting Dipole Magnet Detector
    Zhang, Yongjie
    Xin, Canjie
    Gao, Peifeng
    He, Tianhu
    Guan, Mingzhi
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2023, 213 (1-2) : 121 - 137
  • [3] Strain Measurement Method Based on External Symmetrical Compensation Bridge Composed of Strain Gauges with Four-Wire Configuration for a Large-Scale NbTi Superconducting Dipole Magnet Detector
    Yongjie Zhang
    Canjie Xin
    Peifeng Gao
    Tianhu He
    Mingzhi Guan
    Journal of Low Temperature Physics, 2023, 213 : 121 - 137