Comparison of balloon-expandable valves versus self-expandable valves in high-risk patients undergoing transcatheter aortic valve replacement for severe aortic stenosis

被引:1
作者
Chang, Hsiao-Huang [1 ]
Chen, I-Ming [1 ]
Chen, Po-Lin [1 ]
Hsu, Tsui-Lieh [2 ]
Lin, Su-Man [3 ]
Chen, Ying-Hwa [2 ,4 ]
机构
[1] Taipei Vet Gen Hosp, Dept Surg, Div Cardiovasc Surg, Taipei 112, Taiwan
[2] Taipei Vet Gen Hosp, Dept Internal Med, Div Cardiol, Taipei 112, Taiwan
[3] Taipei Vet Gen Hosp, Dept Anesthesiol, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
关键词
aortic stenosis; Edwards SAPIEN XT; Medtronic CoreValve; transcatheter aortic valve implantation; ACUTE KIDNEY INJURY; EDWARDS SAPIEN; IMPLANTATION; OUTCOMES; DEFINITIONS; PROSTHESIS; REGISTRY;
D O I
10.1016/j.jcma.2015.02.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transcatheter aortic valve implantation (TAVI) has emerged as an alternative to surgical aortic valve replacement for patients with symptomatic severe aortic stenosis (AS) who have a high surgical risk. In Taiwan, this is the first study reporting TAVI outcomes at a single center offering two different transcatheter heart valve technologies via four types of approaches. Our aim was to compare 30-day and 6-month Valve Academic Research Consortium-2 (VARC-2) outcomes of the two valves. Methods: We reported the procedural, 30-day, and 6-month VARC-2 outcomes of high-risk patients who were consecutively treated with the Medtronic CoreValve (MCV) or with the Edwards SAPIEN valve or SAPIEN XT valve (ESV; Edwards Lifesciences, Irvine, CA, USA) delivered via four types of approaches. Results: From May 2010 to December 2013, 30 consecutive patients with severe AS underwent TAVI: 15 patients were treated with the MCV and 15 patients were treated with the ESV. The transfemoral approach was the most frequently used route (13 MCV and 6 ESV), followed by the transapical approach (9 ESV), trans-subclavian approach (1 MCV), and direct aortic approach (1 MCV). There were no procedural deaths. "Device success" was achieved in 29 (96.7%) patients, and is defined as the absence of procedural mortality, correct positioning of one prosthetic heart valve into the proper anatomical location, and intended performance of the heart valve without moderate or severe regurgitation. The VARC-2 defined combined safety endpoint at 30 days was comparable between patients treated with the ESV and the MCV (33.3% vs. 20%, respectively; group, p = 0.409). At the 6-month follow up, the combined efficacy endpoint was not significantly different between the two groups (13.3% in the ESV group vs. 20% in the MCV group; p = 0.624). There was only one (3.3%) patient who required permanent pacemaker implantation. Conclusion: For the first time in Taiwan, we have demonstrated that TAVI using either device is complementary and feasible for treating a wide range of patients by using a careful selection of approaches. Favorable overall procedural success rates and 30-day and 6-month outcomes were achieved with both devices. Copyright (C) 2015 Elsevier Taiwan LLC and the Chinese Medical Association. All rights reserved.
引用
收藏
页码:331 / 338
页数:8
相关论文
共 32 条
[1]   Transcatheter Aortic Valve Implantation Assessing the Learning Curve [J].
Alli, Oluseun O. ;
Booker, Jeffrey D. ;
Lennon, Ryan J. ;
Greason, Kevin L. ;
Rihal, Charanjit S. ;
Holmes, David R., Jr. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :72-79
[2]   Evaluation of Patients With Severe Symptomatic Aortic Stenosis Who Do Not Undergo Aortic Valve Replacement The Potential Role of Subjectively Overestimated Operative Risk [J].
Bach, David S. ;
Siao, Derrick ;
Girard, Steven E. ;
Duvernoy, Claire ;
McCallister, Benjamin D., Jr. ;
Gualano, Sarah K. .
CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2009, 2 (06) :533-539
[3]   Surgeon volume and operative mortality in the United States [J].
Birkmeyer, JD ;
Stukel, TA ;
Siewers, AE ;
Goodney, PP ;
Wennberg, DE ;
Lucas, FL .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (22) :2117-2127
[4]  
Bonow Robert O, 2008, Circulation, V118, pe523, DOI 10.1161/CIRCULATIONAHA.108.190748
[5]   To operate or not on elderly patients with aortic stenosis: the decision and its consequences [J].
Bouma, BJ ;
van den Brink, RBA ;
van der Meulen, JHP ;
Verheul, HA ;
Cheriex, EC ;
Hamer, HPM ;
Dekker, E ;
Lie, KI ;
Tijssen, JGP .
HEART, 1999, 82 (02) :143-148
[6]   Direct Aortic Access for Transcatheter Self-Expanding Aortic Bioprosthetic Valves Implantation [J].
Bruschi, Giuseppe ;
de Marco, Federico ;
Botta, Luca ;
Cannata, Aldo ;
Oreglia, Jacopo ;
Colombo, Paola ;
Barosi, Alberto ;
Colombo, Tiziano ;
Nonini, Sandra ;
Paino, Roberto ;
Klugmann, Silvio ;
Martinelli, Luigi .
ANNALS OF THORACIC SURGERY, 2012, 94 (02) :497-503
[7]  
Chen YH, 2011, ACTA CARDIOL SIN, V27, P213
[8]   Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Versus the Medtronic CoreValve Revalving System Devices A Multicenter Collaborative Study: The PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration) [J].
Chieffo, Alaide ;
Buchanan, Gill Louise ;
Van Mieghem, Nicolas M. ;
Tchetche, Didier ;
Dumonteil, Nicolas ;
Latib, Azeem ;
van der Boon, Robert M. A. ;
Vahdat, Olivier ;
Marcheix, Bertrand ;
Farah, Bruno ;
Serruys, Patrick W. ;
Fajadet, Jean ;
Carrie, Didier ;
de Jaegere, Peter P. T. ;
Colombo, Antonio .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (08) :830-836
[9]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[10]   Technique of Transcatheter Aortic Valve Implantation with the Edwards-Sapien® Heart Valve Using the Transfemoral Approach [J].
Cribier, Alain ;
Litzler, Pierre-Yves ;
Eltchaninoff, Helene ;
Godin, Matthieu ;
Tron, Christophe ;
Bauer, Fabrice ;
Bessou, Jean-Paul .
HERZ, 2009, 34 (05) :347-356