Modelling the forced-air cooling mechanisms and performance of polylined horticultural produce

被引:63
作者
O'Sullivan, Justin [1 ]
Ferrua, Maria J. [1 ]
Love, Richard [1 ]
Verboven, Pieter [2 ]
Nicolai, Bart [2 ]
East, Andrew [1 ]
机构
[1] Massey Univ, Massey Inst Food Sci & Technol, Private Bag 11-222, Palmerston North 4442, New Zealand
[2] Univ Leuven, Div BIOSYST MeBioS, Postharvest Grp, Willem de Croylaan 42, Heverlee, Belgium
关键词
CFD; Precooling; Horticulture; Polyliner; Packaging; Heat transfer; FRESH STRAWBERRY PACKAGES; HEAT-TRANSFER CHARACTERISTICS; SOLUBLE-SOLIDS; DRY-MATTER; EXPERIMENTAL VALIDATION; FLOW; KIWIFRUIT; DENSITY; HAYWARD; DESIGN;
D O I
10.1016/j.postharvbio.2016.05.008
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
A 3-D computational fluid dynamics (CFD) model was developed to describe and predict the temperature profiles of palletised polylined kiwifruit packages undergoing forced-air cooling. The geometrical configuration of the kiwifruit, polyliner and cardboard box were explicitly modelled. The model included the effects of natural convection on the airflow behaviour and heat transfer process occurring within the packed fruits inside the polyliner. The capability of the model to predict the fruit temperatures in each package was quantitatively validated against experimental data. A laboratory scaled experimental rig was used to monitor the forced-air cooling process of a half pallet of kiwifruit boxes under controlled operating conditions. The numerical model was able to predict cooling times within experimental error. Cooling within the pallet was primarily influenced by air temperature and to a lesser extent airflow distribution into each package. A maximum recommended volumetric flowrate through the pallet of 0.34 L kg(-1) s(-1), far lower than flowrates recommended for the cooling of non-polylined produce, was identified. Successive increases to the flowrate, particularly beyond 0.34 L kg(-1) s(-1), resulted in increasingly diminished reductions (< 12%) to cooling rate. Within the polyliner there was a low transfer of energy between kiwifruit and kiwifruit surrounding air. Instead cooling was reliant on the air temperature flowing over the top of the polyliner. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 35
页数:13
相关论文
共 42 条
[1]  
[Anonymous], KIWIFRUIT RECOMMENDA
[2]  
[Anonymous], THESIS
[3]  
[Anonymous], CIGR SECT 7 INT TECH
[4]  
[Anonymous], P INT C REFR WASH D
[5]  
[Anonymous], HANDBOOK
[6]  
[Anonymous], P 2 IIR INT C SUST C
[7]  
[Anonymous], COMMUNICATION
[8]  
[Anonymous], P 2 IIR INT C SUST C
[9]   Precooling techniques and applications for horticultural products - a review [J].
Brosnan, T ;
Sun, DW .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (02) :154-170
[10]  
Burdon J, 2011, WOODHEAD PUBL FOOD S, P326