Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapy

被引:51
作者
Al-Mayah, Adil [1 ]
Moseley, Joanne
Velec, Mike
Brock, Kristy
机构
[1] Princess Margaret Hosp, Univ Hlth Network, Radiat Med Program, Toronto, ON M4X 1K9, Canada
关键词
MATERIAL COMPRESSIBILITY; CONSTITUTIVE MODELS; ELASTICITY; ACCURACY; TISSUE; SURGERY; MOTION; DEFORMATIONS; LUBRICATION; PARENCHYMA;
D O I
10.1088/0031-9155/56/15/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Both accuracy and efficiency are critical for the implementation of biomechanical model-based deformable registration in clinical practice. The focus of this investigation is to evaluate the potential of improving the efficiency of the deformable image registration of the human lungs without loss of accuracy. Three-dimensional finite element models have been developed using image data of 14 lung cancer patients. Each model consists of two lungs, tumor and external body. Sliding of the lungs inside the chest cavity is modeled using a frictionless surface-based contact model. The effect of the type of element, finite deformation and elasticity on the accuracy and computing time is investigated. Linear and quadrilateral tetrahedral elements are used with linear and nonlinear geometric analysis. Two types of material properties are applied namely: elastic and hyperelastic. The accuracy of each of the four models is examined using a number of anatomical landmarks representing the vessels bifurcation points distributed across the lungs. The registration error is not significantly affected by the element type or linearity of analysis, with an average vector error of around 2.8 mm. The displacement differences between linear and nonlinear analysis methods are calculated for all lungs nodes and a maximum value of 3.6 mm is found in one of the nodes near the entrance of the bronchial tree into the lungs. The 95 percentile of displacement difference ranges between 0.4 and 0.8 mm. However, the time required for the analysis is reduced from 95 min in the quadratic elements nonlinear geometry model to 3.4 min in the linear element linear geometry model. Therefore using linear tetrahedral elements with linear elastic materials and linear geometry is preferable for modeling the breathing motion of lungs for image-guided radiotherapy applications.
引用
收藏
页码:4701 / 4713
页数:13
相关论文
共 39 条
  • [31] ISOTROPY AND HOMOGENEITY OF LUNG-TISSUE DEFORMATION
    TAI, RC
    LEE, GC
    [J]. JOURNAL OF BIOMECHANICS, 1981, 14 (04) : 243 - 252
  • [32] Factors influencing the accuracy of biomechanical breast models
    Tanner, Christine
    Schnabel, Julia A.
    Hill, Derek L. G.
    Hawkes, David J.
    Leach, Martin O.
    Hose, D. Rodney
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1758 - 1769
  • [33] Simulation of lung behaviour with finite elements : Influence of bio-mechanical parameters
    Villard, PF
    Beuve, M
    Shariat, B
    Baudet, V
    Jaillet, F
    [J]. THIRD INTERNATIONAL CONFERENCE ON MEDICAL INFORMATION VISUALISATION - BIOMEDICAL VISUALISATION (MEDIVIS 2005), PROCEEDINGS, 2005, : 9 - 14
  • [34] Patient-specific finite element modeling of respiratory lung motion using 4D CT image data
    Werner, Rene
    Ehrhardt, Jan
    Schmidt, Rainer
    Handels, Heinz
    [J]. MEDICAL PHYSICS, 2009, 36 (05) : 1500 - 1511
  • [35] Widmaier EP., 2006, VANDERS HUMAN PHYSL, V10th
  • [36] NONUNIFORM LUNG DEFORMATIONS
    WILSON, TA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1983, 54 (06) : 1443 - 1450
  • [37] On the unimportance of constitutive models in computing brain deformation for image-guided surgery
    Wittek, Adam
    Hawkins, Trent
    Miller, Karol
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2009, 8 (01) : 77 - 84
  • [38] MEASUREMENT OF THE MECHANICAL-PROPERTIES OF THE HUMAN-LUNG TISSUE
    ZENG, YJ
    YAGER, D
    FUNG, YC
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (02): : 169 - 174
  • [39] Technical note: A novel boundary condition using contact elements for finite element based deformable image registration
    Zhang, TZ
    Orton, NP
    Mackie, TR
    Paliwal, BR