Phenylalanine Photoinduced Fluorescence and Characterization of the Photoproducts by LC-MS

被引:8
作者
Martin-Tornero, Elisabet [1 ,2 ]
Sierra-Tadeo, Francisco J. [1 ]
Duran-Meras, Isabel [1 ,2 ]
Espinosa-Mansilla, Anunciacion [1 ,2 ]
机构
[1] Univ Extremadura, Dept Analyt Chem, Badajoz 06006, Spain
[2] Univ Extremadura, Res Inst Water Climate Change & Sustainabil IACYS, Badajoz 06006, Spain
关键词
Phenylalanine; Tyrosine; Photoinduced fluorescence; High performance liquidchromatography; Mass spectrometry; AMINO-ACIDS; HUMAN PLASMA; TYROSINE; DERIVATIZATION; SERUM; PHOTOCHEMISTRY; SAMPLES; HPLC;
D O I
10.1007/s10895-019-02449-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Phenylalanine (Phe) is a direct precursor of tyrosine and several neurotransmitters. The accumulation of Phe in the brain generates serious and not recoverable pathologies in children. Early detection in newborns is fundamental to apply the appropriate therapy and avoid irreversible health problems. Although fluorescence is a sensitive and selective technique for the determination of amino acids, the fluorescent analysis of Phe is limited since it exhibits a very low fluorescence quantum yield; however, the fluorescence of Phe increases drastically under UV irradiation when a peroxide medium is used. The aim of this research was to analyze the effect of the UV-radiation on Phe aqueous-peroxide solutions and to study the influence of the chemical environment on the photoinducted fluorescence process. The nature and characteristics of the fluorescent photoproducts generated under off-line UV irradiation in hydrogen peroxide medium were achieved by high performance liquid chromatography (HPLC) using a spectrophotometer detector (DAD) coupled in series with a mass spectrometer (MS) or with a fast scan spectrofluorimetric detector (FSFD). Environmental characteristics such as pH, initial concentration of Phe, hydrogen peroxide amount and irradiation time were studied in order to establish their influence on the formation of each one of the photoproducts. As the formation of several highly fluorescent photoproducts has been confirmed, the possibility of designing a chromatographic system with a post-column on-line photoreactor is open. The measure of the total fluorescence signal generated from Phe at the optimized irradiation time, could be used for the determination, with high sensitivity, of the initial amount of Phe in aqueous media, such as human serum or environmental samples. These aspects are being studied at present.
引用
收藏
页码:1445 / 1455
页数:11
相关论文
共 30 条
  • [1] [Anonymous], 13 INT C INSTR AN CO
  • [2] [Anonymous], PROTOCOLOS DIAGNOSTI
  • [3] [Anonymous], 2001, METABOLIC MOL BASES
  • [4] [Anonymous], METHODS MOL BIOL
  • [5] [Anonymous], 2005, CHEM ED, DOI DOI 10.1333/S00897050933A
  • [6] Determination of marker pteridins and biopterin reduced forms, tetrahydrobiopterin and dihydrobiopterin, in human urine, using a post-column photoinduced fluorescence liquid chromatographic derivatization method
    Canada-Canada, Florentina
    Espinosa-Mansilla, Anunciacion
    Munoz de la Pena, Arsenio
    Mancha de Llanos, Alicia
    [J]. ANALYTICA CHIMICA ACTA, 2009, 648 (01) : 113 - 122
  • [7] CHEN R F, 1967, Analytical Letters, V1, P35
  • [8] Danafar H., 2015, PHARM BIOMED RES, V1, P11, DOI [10.18869/acadpub.pbr.1.3.11, DOI 10.3109/10837450.2015.1125920]
  • [9] Kinetic of adsorption and of photocatalytic degradation of phenylalanine effect of pH and light intensity
    Elsellami, L.
    Vocanson, F.
    Dappozze, F.
    Puzenat, E.
    Paisse, O.
    Houas, A.
    Guillard, C.
    [J]. APPLIED CATALYSIS A-GENERAL, 2010, 380 (1-2) : 142 - 148
  • [10] High-Speed Quantitative UPLC-MS Analysis of Multiple Amines in Human Plasma and Serum via Precolumn Derivatization with 6-Aminoquinolyl-N-hydroxysuccinimidyl Carbamate: Application to Acetaminophen-Induced Liver Failure
    Gray, Nicola
    Zia, Rabiya
    King, Adam
    Patel, Vishal C.
    Wendon, Julia
    McPhail, Mark J. W.
    Coen, Muireann
    Plumb, Robert S.
    Wilson, Ian D.
    Nicholson, Jeremy K.
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (04) : 2478 - 2487