Analytically Sensitive Protein Detection in Microtiter Plates by Proximity Ligation with Rolling Circle Amplification

被引:24
|
作者
Ebai, Tonge [1 ]
Souza de Oliveira, Felipe Marques [1 ]
Lof, Liza [1 ]
Wik, Lotta [1 ]
Schweiger, Caroline [2 ,4 ]
Larsson, Anders [3 ]
Keilholtz, Ulrich [4 ]
Haybaeck, Johannes [2 ,5 ]
Landegren, Ulf [1 ]
Kamali-Moghaddam, Masood [1 ]
机构
[1] Uppsala Univ, Dept Immunol Genet & Pathol, Sci Life Lab, Uppsala, Sweden
[2] Univ Berlin, Charite Comprehens Canc Ctr, Berlin, Germany
[3] Uppsala Univ, Dept Med Sci Biochem Struct & Funct, Uppsala, Sweden
[4] Med Univ Graz, Inst Pathol, Graz, Austria
[5] Otto von Guericke Univ, Dept Pathol, Magdeburg, Germany
基金
欧洲研究理事会; 瑞典研究理事会;
关键词
ALZHEIMERS-DISEASE; ANTIGEN-DETECTION; IMMUNO-PCR; IN-SITU; ASSAYS; PHOSPHORYLATION; TAU;
D O I
10.1373/clinchem.2017.271833
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Detecting proteins at low concentrations in plasma is crucial for early diagnosis. Current techniques in clinical routine, such as sandwich ELISA, provide sensitive protein detection because of a dependence on target recognition by pairs of antibodies, but detection of still lower protein concentrations is often called for. Proximity ligation assay with rolling circle amplification (PLARCA) is a modified proximity ligation assay (PLA) for analytically specific and sensitive protein detection via binding of target proteins by 3 antibodies, and signal amplification via rolling circle amplification (RCA) in microtiter wells, easily adapted to instrumentation in use in hospitals. METHODS: Proteins captured by immobilized antibodies were detected using a pair of oligonucleotide-conjugated antibodies. Upon target recognition these PLA probes guided oligonucleotide ligation, followed by amplification via RCA of circular DNA strands that formed in the reaction. The RCA products were detected by horseradish peroxidase-labeled oligonucleotides to generate colorimetric reaction products with readout in an absorbance microplate reader. RESULTS: We compared detection of interleukin (IL)-4, IL-6, IL-8, p53, and growth differentiation factor 15 (GDF-15) by PLARCA and conventional sandwich ELISA or immuno-RCA. PLARCA detected lower concentrations of proteins and exhibited a broader dynamic range compared to ELISA and iRCA using the same antibodies. IL-4 and IL-6 were detected in clinical samples at femtomolar concentrations, considerably lower than for ELISA. CONCLUSIONS: PLARCA offers detection of lower protein levels and increased dynamic ranges compared to ELISA. The PLARCA procedure may be adapted to routine instrumentation available in hospitals and research laboratories. (C) 2017 American Association for Clinical Chemistry
引用
收藏
页码:1497 / 1505
页数:9
相关论文
共 50 条
  • [1] Accurate and sensitive low-density lipoprotein (LDL) detection based on the proximity ligation assisted rolling circle amplification (RCA)
    Zhang, Xingyu
    Li, Jie
    Yang, Mei
    Huang, Hong
    Wang, Hao
    Zhang, Hongmin
    ANALYTICAL METHODS, 2024, 16 (13) : 1894 - 1900
  • [2] Sensitive colorimetric detection of protein by gold nanoparticles and rolling circle amplification
    Chen, Chaohui
    Luo, Ming
    Ye, Tai
    Li, Ningxing
    Ji, Xinghu
    He, Zhike
    ANALYST, 2015, 140 (13) : 4515 - 4520
  • [3] Sensitive and specific microRNA detection by RNA dependent DNA ligation and rolling circle optical signal amplification
    Zhou, Chuan
    Huang, Ru
    Zhou, Xiaoming
    Xing, Da
    TALANTA, 2020, 216
  • [4] CE combined with rolling circle amplification for sensitive DNA detection
    Li, Ni
    Li, Jishan
    Zhong, Wenwan
    ELECTROPHORESIS, 2008, 29 (02) : 424 - 432
  • [5] Protein detection based on rolling circle amplification sensors
    Shi, Haixia
    Cui, Jingjie
    Sulemana, Husseini
    Wang, Wunian
    Gao, Li
    LUMINESCENCE, 2021, 36 (04) : 842 - 848
  • [6] Sensitive and Label-Free DNA Methylation Detection by Ligation-Mediated Hyperbranched Rolling Circle Amplification
    Cao, Anping
    Zhang, Chun-yang
    ANALYTICAL CHEMISTRY, 2012, 84 (14) : 6199 - 6205
  • [7] Homogeneous multiplexed digital detection of microRNA with ligation-rolling circle amplification
    Hu, Zhian
    Xu, Fujian
    Sun, Gongwei
    Zhang, Sichun
    Zhang, Xinrong
    CHEMICAL COMMUNICATIONS, 2020, 56 (40) : 5409 - 5412
  • [8] Proximity hybridization triggered rolling-circle amplification for sensitive electrochemical homogeneous immunoassay
    Gao, Fenglei
    Zhou, Fuyi
    Chen, Songjie
    Yao, Yao
    Wu, Jing
    Yin, Dengyang
    Geng, Deqin
    Wang, Po
    ANALYST, 2017, 142 (22) : 4308 - 4316
  • [9] Sensitive detection of microRNA by chronocoulometry and rolling circle amplification on a gold electrode
    Yao, Bo
    Liu, Yichen
    Tabata, Miyuki
    Zhu, Huangtianzhi
    Miyahara, Yuji
    CHEMICAL COMMUNICATIONS, 2014, 50 (68) : 9704 - 9706
  • [10] Accurate Thrombin Monitoring Based on Proximity Ligation Assay-Assisted Rolling Circle Amplification (RCA)
    Du, HuiQun
    Chang, MengHan
    Zhang, JunLiang
    Zhou, Hao
    Shi, Xin
    Zhou, Xing
    MOLECULAR BIOTECHNOLOGY, 2024, 66 (02) : 270 - 276