The Energy Dissipative Rocking Column is a novel seismic mitigation device that could effectively mitigate maximum inter-storey drift and drift concentration of low-rise buildings under earthquakes. This study proposed a beam-through configuration for the connections between steel frames and Energy Dissipative Rocking Columns (EDRCs) to reduce the necessary workload in the application of EDRCs. The study commenced with a cyclic loading test on a substructure composed of the beam-through EDRC and frame beam-to-EDRC connections. Following the cyclic loading test, a simplified numerical model of the beam-through EDRC was built and validated against the test results. Finally, parametric studies were conducted to determine the seismic demand on the beam-to-EDRC connections. The results showed that the beam-through EDRCs have acceptable lateral resisting and energy dissipation capacity. The simplified numerical model could reasonably well predict the hysteretic behaviour of the specimens with and without the steel damper. The parametric study results, based on hundreds of nonlinear time history analyses, indicated that increasing connection stiffness in the range of 0 to 1.5 is most effective in mitigating both maximum drift and drift concentration. Moreover, the beam-through EDRC has very close effectiveness with the conventional column-through EDRC when the connection stiffness ratio is close to or larger than 4.
引用
收藏
页数:11
相关论文
共 44 条
  • [31] Seismic performance of precast UHPC pipe pile with two pile-cap beam connection types: An experimental and numerical study
    Zhou, Mi
    Zhao, Xiaonan
    Song, Jianwei
    Xu, Zitao
    Yin, Shujun
    Zhu, Guoqiang
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 186
  • [32] Experimental study and numerical analysis on seismic performance of FRP confined high-strength rectangular concrete-filled steel tube columns
    Chen, Zhihua
    Dong, Shaohua
    Du, Yansheng
    THIN-WALLED STRUCTURES, 2021, 162
  • [33] Seismic Behavior of Precast Bridge Column-Cap Beam Joints with Grouted Corrugated Duct Connections: Experimental and Numerical Study
    Xu, Yazhou
    Wei, Kelun
    Zhang, Zuzhen
    Wang, Jiangbo
    Mao, Huinan
    Fu, Wenjie
    JOURNAL OF BRIDGE ENGINEERING, 2023, 28 (03)
  • [34] Experimental and numerical study about seismic retrofitting of corrosion-damaged reinforced concrete columns of bridge using combination of FRP wrapping and steel profiles
    Afshin, Hassan
    Shirazi, Mohammad R. Nouri
    Abedi, Karim
    STEEL AND COMPOSITE STRUCTURES, 2019, 30 (03) : 231 - 251
  • [35] Experimental Study and Numerical Analysis of the Seismic Performance of Glass-Fiber Reinforced Plastic Tube Ultra-High Performance Concrete Composite Columns
    Tan, Xiaopeng
    Zhu, Mingqiao
    Liu, Wanli
    MATERIALS, 2023, 16 (21)
  • [36] Seismic performance of reinforced concrete beam-column joints with diagonal bars wrapped by steel tubes: experimental, numerical and analytical study
    Shen, Xinyu
    Li, Bo
    Chen, Yung-Tsang
    STRUCTURES, 2024, 59
  • [37] Seismic performance of square concrete-filled steel tubular column-composite beam single-side bolted joints: An experimental and numerical study
    Ding, Faxing
    Zhang, Shaosong
    Pan, Zhicheng
    Lei, Jianxiong
    Wang, Liping
    Duan, Linli
    ENGINEERING STRUCTURES, 2025, 322
  • [38] Development and experimental seismic study of bearing-two-level yielding energy dissipation beam-column-slab joints for precast concrete frames
    Zhang, Jianxin
    Zhang, Tingwei
    Yuan, Weitao
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [39] Numerical study on the seismic performance of H-beam to built-in CFRP circular tube CFST column joint with replaceable energy dissipation angle steel
    Li, Guochang
    Qin, Zhuangwen
    Li, Xiao
    Liu, Mo
    STRUCTURES, 2024, 67
  • [40] Experimental and numerical study of dynamic responses of a new combined TLP type floating wind turbine and a wave energy converter under operational conditions
    Ren, Nianxin
    Ma, Zhe
    Shan, Baohua
    Ning, Dezhi
    Ou, Jinping
    RENEWABLE ENERGY, 2020, 151 : 966 - 974