Alumina ceramic bearings for total hip arthroplasty - Five-year results of a prospective randomized study

被引:104
作者
D'Antonio, J
Capello, W
Manley, M
Naughton, M
Sutton, K
机构
[1] Indiana Univ, Sch Med, Dept Orthopaed Surg, Indianapolis, IN 46204 USA
[2] Greater Pittsburgh Orthopaed Assoc, Moon Township, PA USA
[3] Clin Measurement Corp, Ridgewood, NJ USA
[4] Stryker Othopaed, Mahwah, NJ USA
关键词
D O I
10.1097/01.blo.0000162995.50971.39
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Three hundred twenty-eight ceramic bearings were implanted by six surgeons in 316 patients as a part of a prospective randomized US Investigational Device Exemption study comparing alumina ceramic bearings with cobalt chrome-on-polyethylene bearings. There was no difference between the control metal-on-polyethylene and the alumina bearing couple patient cohorts regarding demographics or clinical scores through 7 years. Revision for any reason occurred in 2.7% of the patients with alumina bearings and 7.5% of the control patients with polyethylene bearings. Osteolysis was found in 1.4% of the patients with alumina bearings and in 14.0% of the control patients. At an average followup of 5.0 years (range, 1-86 months) no ceramic fractures or ceramic bearing failures have occurred. Results of this study suggest that alumina ceramics perform as well as the metal-on-polyethylene in clinical scores, but the patients with ceramic bearings had fewer revisions and less osteolysis. These results lead us to think that this new alumina ceramic bearing provides a safe option for younger and more active patients.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 55 条
  • [1] Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene
    Anissian, HL
    Stark, A
    Gustafson, A
    Good, V
    Clarke, IC
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06): : 578 - 582
  • [2] Ceramic acetabular cups for total hip replacement - Part 6: Cup design, inclination angle and antetorsion angle have an influence on the range of motion and impingement
    Bader, R
    Willmann, G
    [J]. BIOMEDIZINISCHE TECHNIK, 1999, 44 (7-8): : 212 - 219
  • [3] BIZOT P, 2001, CLIN ORTHOP RELAT R, V393, P85
  • [4] LONG-TERM RESULTS OF UNCEMENTED ALUMINA ACETABULAR IMPLANTS
    BOEHLER, M
    KNAHR, K
    PLENK, H
    WALTER, A
    SALZER, M
    SCHREIBER, V
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01): : 53 - 59
  • [5] Wear debris from two different alumina-on-alumina total hip arthroplasties
    Böhler, M
    Mochida, Y
    Bauer, TW
    Plenk, H
    Salzer, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (06): : 901 - 909
  • [6] THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT
    BOUTIN, P
    CHRISTEL, P
    DORLOT, JM
    MEUNIER, A
    DEROQUANCOURT, A
    BLANQUAERT, D
    HERMAN, S
    SEDEL, L
    WITVOET, J
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12): : 1203 - 1232
  • [7] Metal-on-metal bearing with THA and chronic renal failure.
    Brodner, V
    Grohs, JG
    Bitzan, P
    Meisinger, V
    Kovarik, J
    Kotz, R
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (05): : 425 - 429
  • [8] Results of Charnley total hip arthroplasty at a minimum of thirty years - A concise follow-up of a previous report
    Callaghan, JJ
    Templeton, JE
    Liu, SS
    Pedersen, DR
    Goetz, DD
    Sullivan, PM
    Johnston, RC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04) : 690 - 695
  • [9] Campbell P, 1996, Proc Inst Mech Eng H, V210, P167, DOI 10.1243/PIME_PROC_1996_210_409_02
  • [10] CAMPBELL P, 2004, CLIN ORTHOP RELAT R, V418, P98