In Vivo Three-Dimensional MR Wall Shear Stress Estimation in Ascending Aortic Dilatation

被引:85
|
作者
Bieging, Erik T.
Frydrychowicz, Alex
Wentland, Andrew [2 ]
Landgraf, Benjamin R.
Johnson, Kevin M. [2 ]
Wieben, Oliver [2 ]
Francois, Christopher J. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Clin Sci Ctr E1, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
关键词
flow-sensitive MRI; ascending aortic aneurysm; wall shear stress; hemodynamics; PHASE-CONTRAST MRI; FLOW PATTERNS; BLOOD-FLOW; HEALTHY-VOLUNTEERS; ANEURYSMS; QUANTIFICATION; HEMODYNAMICS; SIZE; ANGIOGRAPHY; RUPTURE;
D O I
10.1002/jmri.22485
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate surface-based wall shear stress (WSS) and evaluate flow patterns in ascending aortic dilatation (AscAD) using a high-resolution, time-resolved, three-dimensional (3D), three-directional velocity encoded, radially undersampled phase contrast MR sequence (4D PC-MRI). Materials and Methods: 4D PC-MRI was performed in 11 patients with AscAD (46.3 +/- 22.0 years) and 10 healthy volunteers (32.9 +/- 13.4 years) after written informed consent and institutional review board approval. Following manual vessel wall segmentation of the ascending aorta (MATLAB, The Mathworks, Natick, MA), a 3D surface was created using spline interpolation. Spatial WSS variation based on surface division in 12 segments and temporal variation were evaluated in AscAD and normal aortas. Visual analysis of flow patterns was performed based on streamlines and particle traces using En Sight (v9.0, CEI, Apex, NC). Results: AscAD was associated with significantly increased diastolic WSS, decreased systolic to diastolic WSS ratio, and delayed onset of peak WSS (all P < 0.001). Temporally averaged WSS was increased and peak systolic WSS was decreased. The maximum WSS in AscAD was on the anterior wall of the ascending aorta. Vortical flow with highest velocities along the anterior wall and Increased helical flow during diastole were observed in AscAD compared with controls. Conclusion: Changes in WSS in the ascending aorta of AscAD correspond to observed alterations in flow patterns compared to controls.
引用
收藏
页码:589 / 597
页数:9
相关论文
共 50 条
  • [21] Bileaflet mechanical aortic valves do not alter ascending aortic wall shear stress
    Emile S. Farag
    Emilio L. Schade
    Pim van Ooij
    S. Matthijs Boekholdt
    R. Nils Planken
    Roland van Kimmenade
    Aart J. Nederveen
    Bas A. J. M. de Mol
    Jolanda Kluin
    The International Journal of Cardiovascular Imaging, 2019, 35 : 703 - 710
  • [22] Aortic dilatation associates with flow displacement and increased circumferential wall shear stress in patients without aortic stenosis: A prospective clinical study
    Kauhanen, S. Petteri
    Hedman, Marja
    Kariniemi, Elina
    Jaakkola, Pekka
    Vanninen, Ritva
    Saari, Petri
    Liimatainen, Timo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (01) : 136 - 145
  • [23] Three-Dimensional Flow Characteristics in Aortic Coarctation and Poststenotic Dilatation
    Markl, Michael
    Arnold, Raoul
    Hirtler, Daniel
    von zur Muhlen, Constantin
    Harloff, Andreas
    Langer, Mathias
    Hennig, Juergen
    Frydrychowicz, Alex
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (05) : 776 - 778
  • [24] Influence of aortic valve morphology on vortical structures and wall shear stress
    Jonnagiri, Raghuvir
    Sundstrom, Elias
    Gutmark, Ephraim
    Anderson, Shae
    Pednekar, Amol S.
    Taylor, Michael D.
    Tretter, Justin T.
    Gutmark-Little, Iris
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2023, 61 (06) : 1489 - 1506
  • [25] Effects of wall shear stress and fluid recirculation on the localization of circulating monocytes in a three-dimensional flow model
    Pritchard, WF
    Davies, PF
    Derafshi, Z
    Polacek, DC
    Tsao, RC
    Dull, RO
    Jones, SA
    Giddens, DP
    JOURNAL OF BIOMECHANICS, 1995, 28 (12) : 1459 - 1469
  • [26] Increased Ascending Aortic Wall Stress in Patients With Bicuspid Aortic Valves
    Nathan, Derek P.
    Xu, Chun
    Plappert, Ted
    Desjardins, Benoit
    Gorman, Joseph H., III
    Bavaria, Joseph E.
    Gorman, Robert C.
    Chandran, Krishnan B.
    Jackson, Benjamin M.
    ANNALS OF THORACIC SURGERY, 2011, 92 (04) : 1384 - 1389
  • [27] Evaluation of Peak Wall Stress in an Ascending Thoracic Aortic Aneurysm Using FSI Simulations: Effects of Aortic Stiffness and Peripheral Resistance
    Campobasso, Rossella
    Condemi, Francesca
    Viallon, Magalie
    Croisille, Pierre
    Campisi, Salvatore
    Avril, Stephane
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) : 707 - 722
  • [28] Shear Stress and Aortic Strain Associations With Biomarkers of Ascending Thoracic Aortic Aneurysm
    Pasta, Salvatore
    Agnese, Valentina
    Gallo, Alessia
    Cosentino, Federica
    Di Giuseppe, Marzio
    Gentile, Giovanni
    Raffa, Giuseppe M.
    Maalouf, Joseph F.
    Michelena, Hector, I
    Bellavia, Diego
    Conaldi, Pier Giulio
    Pilato, Michele
    ANNALS OF THORACIC SURGERY, 2020, 110 (05) : 1595 - 1604
  • [29] Aortic wall shear stress in bicuspid aortic valve disease-10-year follow-up
    Hanigk, Michael
    Burgstaller, Elisabeth
    Latus, Heiner
    Shehu, Nerejda
    Zimmermann, Judith
    Martinoff, Stefan
    Hennemuth, Anja
    Ewert, Peter
    Stern, Heiko
    Meierhofer, Christian
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2023, 13 (01) : 38 - 50
  • [30] Reproducibility of Flow and Wall Shear Stress Analysis Using Flow-Sensitive Four-Dimensional MRI
    Markl, Michael
    Wallis, Wolf
    Harloff, Andreas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 988 - 994