摘要
Although the value of high-density surface electromyography (sEMG) has already been proven in fundamental research and for specific diagnostic questions, there is as yet no broad clinical application. This is partly due to limitations of construction principles and application techniques of conventional electrode array systems. We developed a thin, highly flexible, two-dimensional multielectrode sEMG grid, which is manufactured by using flexprint techniques. The material used as electrode carrier (Polyimid, 50 mum thick) allows grids to be cut out in any required shape or size. One universal grid version can therefore be used for many applications, thereby reducing costs. The reusable electrode grid is attached to the skin by using specially prepared double-sided adhesive tape, which allows the selective application of conductive cream only directly below the detection surfaces. To explore the practical possibilities, this technique was applied in single motor unit analysis of the facial musculature. The high mechanical flexibility allowed the electrode grid to follow the skin surface even in areas with very uneven contours, resulting in good electrical connections in the whole recording area. The silver-chloride surfaces of the electrodes and their low electrode-to-skin impedances guaranteed high baseline stability and a low signal noise level. The electrode- to-skin attachment proved to withstand saliva and great tensile forces due to mimic contractions. The inexpensive, universally adaptable and minimally obstructive sensor allows the principal advantages of high-density sEMG to be extended to all skeletal muscles accessible from the skin surface and may lay the foundation for more broad clinical application of this noninvasive, two-dimensional sEMG technique.
引用
收藏
页码:327 / 336
页数:10
相关论文
共 43 条
  • [1] [Anonymous], 1972, ELECTRODES MEASUREME
  • [2] INTERDIGITATING MUSCLE-FIBERS THROUGHOUT ORBICULARIS ORIS INFERIOR - PRELIMINARY-OBSERVATIONS
    BLAIR, C
    [J]. JOURNAL OF SPEECH AND HEARING RESEARCH, 1986, 29 (02): : 266 - 269
  • [3] EMG RECORDING IN HUMAN LIP MUSCLES - CAN SINGLE MUSCLES BE ISOLATED
    BLAIR, C
    SMITH, A
    [J]. JOURNAL OF SPEECH AND HEARING RESEARCH, 1986, 29 (02): : 256 - 266
  • [4] A high-density multichannel surface electromyography system for the characterization of single motor units
    Blok, JH
    van Dijk, JP
    Drost, G
    Zwarts, MJ
    Stegeman, DF
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (04) : 1887 - 1897
  • [5] Braus H, 1954, ANATOMIE MENSCHEN LE, V1
  • [6] A MINIATURE ELECTRODE FOR SURFACE ELECTROMYOGRAPHY DURING SPEECH
    COLE, KJ
    KONOPACKI, RA
    ABBS, JH
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1983, 74 (05) : 1362 - 1366
  • [7] Cooper R., 1980, EEG TECHNOLOGY
  • [8] Improvement of spatial resolution in surface-EMG: A theoretical and experimental comparison of different spatial filters
    DisselhorstKlug, C
    Silny, J
    Rau, G
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (07) : 567 - 574
  • [9] Propagation disturbance of motor unit action potentials during transient paresis in generalized myotonia - A high-density surface EMG study
    Drost, G
    Blok, JH
    Stegeman, DF
    van Dijk, JP
    van Engelen, BGM
    Zwarts, MJ
    [J]. BRAIN, 2001, 124 : 352 - 360
  • [10] Location of innervation zones of sternocleidomastoid and scalene muscles - a basis for clinical and research electromyography applications
    Falla, D
    Dall'Alba, P
    Rainoldi, A
    Merletti, R
    Jull, G
    [J]. CLINICAL NEUROPHYSIOLOGY, 2002, 113 (01) : 57 - 63