The effectiveness of the external distal aiming device in intramedullary fixation of tibial shaft fractures

被引:11
作者
Babis, George C. [1 ]
Benetos, Ioannis S. [1 ]
Zoubos, Aristides B. [1 ]
Soucacos, Panayotis N. [1 ]
机构
[1] Univ Athens, Sch Med, KAT Accident Hosp, Dept Orthopaed, GR-14651 Athens, Greece
关键词
tibial fractures; intramedullary nailing; distal targeting devices; radiation exposure;
D O I
10.1007/s00402-007-0405-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Intramedullary nailing has become a popular and effective procedure for the treatment of most fractures of the tibial diaphysis. However, distal interlocking screw placement under fluoroscopic control is responsible for the majority of the radiation exposure and a significant loss of surgical time in the entire nailing procedure. To limit fluoroscopy use, during distal interlocking screw placement, Orthofix (R) has developed a distal targeting device which compensates for the inevitable deformation of the nail in the sagittal plane during its insertion. This prospective clinical study evaluates the efficacy of this distal targeting device for distal locking. Materials and methods One hundred and fifteen fresh tibial fractures in the same number of patients with a mean age of 37.5 years (17-85 years) were treated with operative stabilization using the Orthofix tibial nailing system. Results The mean duration of the operation was 38 min (20-55 min). A mean of four intra-operative plain X-rays (2-6 X-rays) were used in 103 cases to confirm guide wire placement, final nail insertion and accuracy of screws placement. The mean duration of the use of the image intensifier utilized in the remaining 12 fractures was 5 s (3-8 s). The distal targeting device failed in 12 (5.2%) distal locking screws. Conclusion This study demonstrates that distal locking can be performed easily and successfully with minimal exposure to radiation, once the surgeon develops a reasonable experience with the use of this distal targeting device.
引用
收藏
页码:905 / 908
页数:4
相关论文
共 36 条
[1]   Experimental model for a new distal locking aiming device for solid intramedullary tibia nails [J].
Abdlslam, KM ;
Bonnaire, F .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 (05) :363-366
[2]  
BARRY TP, 1984, CLIN ORTHOP RELAT R, P160
[3]   Operative management of lower extremity fractures in patients with head injuries [J].
Bhandari, M ;
Guyatt, GH ;
Khera, V ;
Kulkarni, AV ;
Sprague, S ;
Schemitsch, EH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (407) :187-198
[4]   Interlocking intramedullary nailing with and without reaming for the treatment of closed fractures of the tibial shaft - A prosepective, randomized study [J].
Blachut, PA ;
OBrien, PJ ;
Meek, RN ;
Broekhuyse, HM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05) :640-646
[5]   CLOSED INTRAMEDULLARY TIBIAL NAILING - ITS USE IN CLOSED AND TYPE-I OPEN FRACTURES [J].
COURTBROWN, CM ;
CHRISTIE, J ;
MCQUEEN, MM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :605-611
[6]   Factors affecting fracture healing after intramedullary nailing of the tibial diaphysis for closed and grade I open fractures [J].
Drosos, GI ;
Bishay, M ;
Karnezis, IA ;
Alegakis, AK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :227-231
[7]  
Gugala Z, 2001, INJURY, V32, pD21
[8]   PREVENTION OF INFECTION IN TREATMENT OF 1000 AND 25 OPEN FRACTURES OF LONG BONES - RETROSPECTIVE AND PROSPECTIVE ANALYSES [J].
GUSTILO, RB ;
ANDERSON, JT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (04) :453-458
[9]   LOCKING NAILING - AN AID TO DISTAL TARGETTING [J].
HUDSON, I .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1989, 20 (03) :129-130
[10]   The clinical performance of a small diameter tibial nailing system with a mechanical distal aiming device [J].
Karachalios, T ;
Babis, G ;
Tsarouchas, J ;
Sapkas, G ;
Pantazopoulos, T .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (06) :451-459