Fluid resuscitation strategies: A systematic review of animal trials

被引:137
作者
Mapstone, J
Roberts, I
Evans, P
机构
[1] Castle Point & Rochford Primary Care Trust, Rayleigh SS6 7QF, Essex, England
[2] London Sch Hyg & Trop Med, Dept Epidemiol & Publ Hlth, Publ Hlth Intervent Res Unit, London WC1, England
[3] Morriston Hosp, Swansea, W Glam, Wales
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2003年 / 55卷 / 03期
关键词
fluid resuscitation; systematic review; hemorrhage; animal; critical care; mortality;
D O I
10.1097/01.TA.0000062968.69867.6F
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Our objective was to systematically review randomized, controlled trials of fluid resuscitation in animal models of uncontrolled hemorrhage and to explore potential sources of heterogeneity. Methods: We conducted an electronic bibliographic search of published research, reviewed reference lists of included trials, and contacted authors about unpublished studies. We included all unconfounded, randomized, controlled trials of fluid resuscitation (timing, volume, or resuscitation targets) in animal models of uncontrolled hemorrhage. The outcome measure was mortality at the end of the scheduled follow-up period of the trial. Two reviewers independently applied the selection criteria to the trial reports. A third reviewer resolved disagreements. Results: Forty-four trials compared fluid versus no fluid resuscitation. There was marked heterogeneity in the effect of fluid resuscitation on the risk of death, much of which was explained by the hemorrhage model used. In aortic injury models, the adjusted relative risk of death with fluid resuscitation was 0.48 (95% confidence interval [CI], 0.33-0.71). In organ incision models, the adjusted relative risk of death was 0.76 (95% CI, 0.49-1.18). In tail resection models, the adjusted relative risk of death was 0.69 (95% CI, 0.38-1.25) if 50% or more was removed and 1.86 (95% CI, 1.13-3.07) if less than 50% was removed. In other vascular injury models, the adjusted relative risk of death with fluid resuscitation was 1.70 (95% CI, 1.01-2.85), respectively. Nine trials compared hypotensive versus normotensive resuscitation. The relative risk of death with hypotensive resuscitation was 0.37 (95% CI, 0.27-0.50). Conclusion: Fluid resuscitation appears to reduce the risk of death in animal models of severe hemorrhage but increases the risk of death in those with less severe hemorrhage. Excessive fluid resuscitation could therefore be harmful in some situations. Hypotensive resuscitation reduced the risk of death in all the trials investigating it. An evaluation of the potential impact of hypotensive resuscitation in humans could now be warranted.
引用
收藏
页码:571 / 589
页数:19
相关论文
共 52 条
[1]   Prehospital resuscitation with phenylephrine in uncontrolled hemorrhagic shock and brain injury [J].
Alspaugh, DM ;
Sartorelli, K ;
Shackford, SR ;
Okum, EJ ;
Buckingham, S ;
Osler, T .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (05) :851-863
[2]  
American College of Surgeons, 1997, ADV TRAUM LIF SUPP
[3]  
[Anonymous], 2001, SYSTEMATIC REV HLTH, DOI DOI 10.1002/9780470693926
[4]  
[Anonymous], 2000, World Health Report 2000: Health Systems: Improving Performance
[5]   USE OF HYPERTONIC SALINE DEXTRAN VERSUS LACTATED RINGERS SOLUTION AS A RESUSCITATION FLUID AFTER UNCONTROLLED AORTIC HEMORRHAGE IN ANESTHETIZED SWINE [J].
BICKELL, WH ;
BRUTTIG, SP ;
MILLNAMOW, GA ;
OBENAR, J ;
WADE, CE .
ANNALS OF EMERGENCY MEDICINE, 1992, 21 (09) :1077-1085
[6]  
BILYNSKYJ MCV, 1992, CIRC SHOCK, V36, P68
[7]   Controlled resuscitation for uncontrolled hemorrhagic shock [J].
Burris, D ;
Rhee, P ;
Kaufmann, C ;
Pikoulis, E ;
Austin, B ;
Eror, A ;
DeBraux, S ;
Guzzi, L ;
Leppäniemi, A .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1999, 46 (02) :216-222
[8]   UNCONTROLLED HEMORRHAGIC-SHOCK OUTCOME MODEL IN RATS [J].
CAPONE, A ;
SAFAR, P ;
STEZOSKI, SW ;
PEITZMAN, A ;
TISHERMAN, S .
RESUSCITATION, 1995, 29 (02) :143-152
[9]  
CAPONE AC, 1995, J AM COLL SURGEONS, V180, P49
[10]  
CRAIG RL, 1994, AM SURGEON, V60, P59