Performance of laboratory tests used to measure blood phenylalanine for the monitoring of patients with phenylketonuria

被引:21
作者
Moat, Stuart J. [1 ,2 ]
Schulenburg-Brand, Danja [1 ]
Lemonde, Hugh [3 ]
Bonham, James R. [4 ]
Weykamp, Cas W. [5 ]
Mei, Joanne V. [6 ]
Shortland, Graham S. [7 ]
Carling, Rachel S. [8 ,9 ]
机构
[1] Univ Hosp Wales, Dept Med Biochem Immunol & Toxicol, Cardiff CF14 4XW, Wales
[2] Cardiff Univ, Univ Hosp Wales, Sch Med, Cardiff, Wales
[3] Guys & St Thomas NHSFT, Evelina Childrens Hosp, Paediat Metab Med, London, England
[4] Sheffield Childrens NHS FT, Dept Clin Chem, Sheffield, S Yorkshire, England
[5] Queen Beatrix Hosp, MCA Lab, Winterswijk, Netherlands
[6] Ctr Dis Control & Prevent, Newborn Screening & Mol Biol Branch, Atlanta, GA USA
[7] Univ Hosp Wales, Dept Child Hlth, Cardiff, Wales
[8] Guys & St Thomas NHSFT, Viapath, Biochem Sci, London, England
[9] Kings Coll London, GKT Sch Med Educ, London, England
关键词
accuracy; bias; dried blood spots; monitoring; phenylketonuria; precision; treatment-ranges; TANDEM MASS-SPECTROMETRY; AMINO-ACIDS; MANAGEMENT; TYROSINE; RECOMMENDATIONS; PLASMA; SPOTS; IMPAIRMENT; DIAGNOSIS; DEVICE;
D O I
10.1002/jimd.12163
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Analysis of blood phenylalanine is central to the monitoring of patients with phenylketonuria (PKU) and age-related phenylalanine target treatment-ranges (0-12 years; 120-360 mu mol/L, and >12 years; 120-600 mu mol/L) are recommended in order to prevent adverse neurological outcomes. These target treatment-ranges are based upon plasma phenylalanine concentrations. However, patients are routinely monitored using dried bloodspot (DBS) specimens due to the convenience of collection. Significant differences exist between phenylalanine concentrations in plasma and DBS, with phenylalanine concentrations in DBS specimens analyzed by flow-injection analysis tandem mass spectrometry reported to be 18% to 28% lower than paired plasma concentrations analyzed using ion-exchange chromatography. DBS specimens with phenylalanine concentrations of 360 and 600 mu mol/L, at the critical upper-target treatment-range thresholds would be plasma equivalents of 461 and 768 mu mol/L, respectively, when a reported difference of 28% is taken into account. Furthermore, analytical test imprecision and bias in conjunction with pre-analytical factors such as volume and quality of blood applied to filter paper collection devices to produce DBS specimens affect the final test results. Reporting of inaccurate patient results when comparing DBS results to target treatment-ranges based on plasma concentrations, together with inter-laboratory imprecision could have a significant impact on patient management resulting in inappropriate dietary change and potentially adverse patient outcomes. This review is intended to provide perspective on the issues related to the measurement of phenylalanine in blood specimens and to provide direction for the future needs of PKU patients to ensure reliable monitoring of metabolic control using the target treatment-ranges.
引用
收藏
页码:179 / 188
页数:10
相关论文
共 46 条
  • [1] [Anonymous], 2012, 151892012 ISO
  • [2] [Anonymous], 2001, METABOLIC MOL BASES
  • [3] MEASUREMENT OF PHENYLALANINE IN ROUTINE CARE OF PHENYLKETONURIC CHILDREN
    BELTON, NR
    CROMBIE, JD
    ROBINS, SP
    STEPHEN, R
    FARQUHAR, JW
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1973, 48 (06) : 472 - 475
  • [4] Bonham JR, 2018, ERNDIM PILOT DBS EQA
  • [5] Burton BK, 2007, J INHERIT METAB DIS, V30, P300
  • [6] Phenylketonuria Scientific Review Conference: State of the science and future research needs
    Camp, Kathryn M.
    Parisi, Melissa A.
    Acosta, Phyllis B.
    Berry, Gerard. T.
    Bilder, Deborah A.
    Blau, Nenad
    Bodamer, Olaf A.
    Brosco, Jeffrey P.
    Brown, Christine S.
    Burlina, Alberto B.
    Burton, Barbara K.
    Chang, Christine S.
    Coates, Paul M.
    Cunningham, Amy C.
    Dobrowolski, Steven F.
    Ferguson, John H.
    Franklin, Thomas D.
    Frazier, Dianne M.
    Grange, Dorothy K.
    Greene, Carol L.
    Groft, Stephen C.
    Harding, Cary O.
    Howell, R. Rodney
    Huntington, Kathleen L.
    Hyatt-Knorr, Henrietta D.
    Jevaji, Indira P.
    Levy, Harvey L.
    Lichter-Konecki, Uta
    Lindegren, Mary Lou
    Lloyd-Puryear, Michele A.
    Matalon, Kimberlee
    MacDonald, Anita
    McPheeters, Melissa L.
    Mitchell, John J.
    Mofidi, Shideh
    Moseley, Kathryn D.
    Mueller, Christine M.
    Mulberg, Andrew E.
    Nerurkar, Lata S.
    Ogata, Beth N.
    Pariser, Anne R.
    Prasad, Suyash
    Pridjian, Gabriella
    Rasmussen, Sonja A.
    Reddy, Uma M.
    Rohr, Frances J.
    Singh, Rani H.
    Sirrs, Sandra M.
    Stremer, Stephanie E.
    Tagle, Danilo A.
    [J]. MOLECULAR GENETICS AND METABOLISM, 2014, 112 (02) : 87 - 122
  • [7] Carling R, 2018, ERNDIM QUANTITATIVE
  • [8] Carling RS, 2018, COMMUNICATION
  • [9] CHACE DH, 1993, CLIN CHEM, V39, P66
  • [10] Chace DH, 1999, CLIN CHEM, V45, P1269